LAN Xiang

Prof. Dr. LAN Xiang

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LXLAN Xiang
LAN Xiang
GWGuanglan Wei
Guanglan Wei
XZXingxian Zhang
Xingxian Zhang
This study investigates the influence of viscous damper parameters on the damping efficiency of frame shear wall structures. Taking a specific frame shear wall structure as the background, a three-dimensional finite element model is established using a nonlinear dynamic time–history analysis method. The damping ratio, reduction in vertex displacement, reduction in base shear, and inter-story drift utilization rate are selected as the damping performance indicators. Firstly, a sensitivity analysis is conducted to study the influence of different viscous damper parameters on these indicators. Then, the relationship models between the viscous damper parameters and the indicators are fitted using the response surface method, and the fitting effect is evaluated through an F-test and determination coefficient R2. Finally, an objective function based on key damping performance indicators is established to solve for the optimal parameters. The results show that the traditional sensitivity analysis method is unable to comprehensively consider the combined effects of different damping efficiency indicators. The response surface method has high fitting accuracy and good predictability and can serve as an optimization model. Considering the stiffness of supporting components matched with the viscous damper parameters, the feasibility of the optimal damping parameters is demonstrated from an engineering application perspective. A simple and easy-to-operate damping design flowchart is proposed, providing important guidance and reference for designers in frame shear wall structure damping design in the future.

1 June 2024 in Buildings
Verified
Journal Article
Open access
PDF file
QZQiang Zhou
Qiang Zhou
WPWen Pan
Wen Pan
LXLAN Xiang
LAN Xiang
This paper proposes a new toggle-style negative stiffness viscous damper (TNVD), and evaluates the performance of the TNVD with the displacement amplification factor (fd) and the energy dissipation factor (fE). Firstly, the composition and characteristics of the TNVD are introduced. Subsequently, the displacement amplification factor is introduced to evaluate the displacement amplification ability of the TNVD, and it is decomposed into a geometric amplification factor and an effective displacement coefficient. Then, based on the geometric amplification factor and effective displacement coefficient, the correlation between the TNVD’s displacement amplification ability and inter-story deformation is studied, and an improved TNVD is proposed. By the comparison of the finite element calculation results, it is found that the improved TNVD can utilize the assumption of small structural deformation. After that, the impacts of plentiful aspects, such as the length of the lower connecting rod, the horizontal inclination angle of the lower connecting rod, the inter-story deformation limit, the cross-sectional area of the connecting rod, the damping coefficient, and the negative stiffness on the fd and fE of the improved TNVD, are expounded. The research results show that when the length of the TNVD’s lower connecting rod remains unchanged, the fd and fE present a trend of increasing first and then decreasing with the increase in the horizontal inclination angle of the lower connecting rod. When the inter-story deformation is fixed, there exists an optimal lower connecting rod’s length that satisfies a specific relationship to achieve the optimal geometric amplification factor of the TNVD. By adjusting the damping parameters of the TNVD, we can obtain a better effective displacement coefficient greater than 0.95 in the proposed target region. Meanwhile, the fd and fE increase with the decrease in the negative stiffness. An optimization strategy for the improved TNVD has been proposed to ensure that the TNVD has the characteristics of operational safety, ideal displacement amplification capability, and energy dissipation capability. Furthermore, a multi-objective control design method with an additional improved TNVD structure is proposed. The vibration reduction effect of the structure with the improved TNVD and the effectiveness of the optimization strategy are verified through examples.

23 May 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LXLAN Xiang
LAN Xiang
LZLongfei Zhang
Longfei Zhang
BSBaifeng Sun
Baifeng Sun
WPWen Pan
Wen Pan
This study specifically focuses on the damping efficiency of a damped structure with additional viscous dampers. A two-layer steel frame structure with eight sets of viscous dampers is used to conduct a series of seismic simulation shaking table tests, including a non-damped structure without dampers and two damped structures with dampers placed at 1/2 and 1/6 of the beam span, respectively. By conducting these tests, the energy dissipation, force, and displacement of the damper, as well as the parameters of the structure such as floor displacement and acceleration, are obtained. The main damping efficiency indicators of the damped structure are calculated, including the additional damping ratio, inter-story displacement utilization rate, as well as the reduction rate of the vertex displacement and the base shear relative to the non-damped structure. The study shows that the viscous dampers exhibit full hysteresis loops and a strong energy dissipation capacity in the structure. The seismic response of the vertex displacement and base shear in the damped structure is significantly smaller than that in the non-damped structure. Under different seismic levels, including frequent earthquakes, occasional earthquakes, and rare earthquakes, the damping effect of the dampers placed at 1/2 of the beam span is significantly better than that placed at 1/6 of the beam span. For example, the additional damping ratio for the X-direction artificial wave REN is 19% and 11%, 20% and 13%, and 13% and 11%, respectively. The patterns for inter-story displacement utilization ratio, reduction rate of the vertex displacement, and reduction rate of the base shear are similar. The research findings strongly indicate that the damped structure with additional viscous dampers exhibits excellent damping efficiency. In future damping design, designers need to fully consider the placement of viscous dampers within the beam span.

7 January 2025 in Buildings
Verified
Journal Article
Open access
PDF file
KWKeChuan Wu
KeChuan Wu
GWGuanglan Wei
Guanglan Wei
CLChi Lin
Chi Lin
LZLongfei Zhang
Longfei Zhang
WYWenzheng Yu
Wenzheng Yu
LXLAN Xiang
LAN Xiang
To investigate the differences in seismic performance of buckling-restrained braces (BRBs) with significantly different lengths and to explore the influence of length on the energy dissipation efficiency of BRBs within the same structure, this study designed and fabricated two BRBs with lengths of 8.5 m and 3 m based on an actual engineering project. Low-cycle reciprocating load tests were conducted to compare the performance of the two BRBs in terms of hysteretic energy dissipation capacity, tension–compression bearing capacity imbalance coefficient, cumulative plastic deformation capacity, and low-cycle fatigue life. Additionally, the energy dissipation and damping efficiency of BRBs of different lengths within the same structure was analyzed. The results indicate that under cyclic loading based on design displacement, the 8.5 m BRB exhibits a greater equivalent viscous damping ratio, cumulative hysteretic energy dissipation, and cumulative plastic deformation, leading to more efficient energy dissipation and damping effects. The length of the brace is a significant factor affecting the imbalance coefficient of tension–compression bearing capacity, with longer braces resulting in a larger imbalance coefficient. The 3 m BRB shows less deviation from the mean values of various fatigue parameters, indicating more stable low-cycle fatigue performance. Within the same structure, shorter BRBs with larger design displacements achieve higher energy dissipation efficiency, allowing for more effective utilization of their energy dissipation capacity. This study’s conclusions provide valuable references for designers in the rational selection of BRBs of different lengths in actual engineering projects and offer preliminary insights into the energy dissipation efficiency of BRBs of varying lengths within a structure.

20 June 2024 in Buildings
Verified
Journal Article
Open access
PDF file
QZQiang Zhou
Qiang Zhou
WPWen Pan
Wen Pan
LXLAN Xiang
LAN Xiang
Generally speaking, the traditional lever amplification damping system is installed between adjacent columns in a building, which occupies a significant amount of space in the building. In contrast to amplification devices in different forms, the damper displacement of the intermediate column damper system is smaller, and the vibration reduction efficiency is lower. In light of these drawbacks, this study proposes a new amplification device for energy dissipation and vibration reduction, which is based on an intermediate column–lever mechanism with a viscous damper (CLVD). Initially, a specific simplified mechanical model of CLVD is derived. Subsequently, an equivalent Kelvin mechanical model of CLVD is derived to intuitively reflect CLVD’s damping and stiffness effect. The damping ratio added by CLVDs to the structure is calculated according to that model; the additional damping ratio and additional stiffness are utilized to calculate the displacement ratio Rd and shear force ratio Rv of the structure with CLVDs to the structure without CLVDs. Rd and Rv are introduced to evaluate the vibration reduction effect of the structure with CLVDs, and the effects of various parameters (such as intermediate column position, beam’s bending line stiffness, lever amplification factor, damping coefficient, and earthquake intensity) on Rd and Rv are analyzed. The results indicate that when the ratio of the distance from the intermediate column to the edge column to the span of the beam is 0.5, CLVD owns the optimal vibration reduction effect. Increasing the beam’s bending line stiffness is beneficial for CLVD to control structural displacement and shear force; when the leverage amplification factor is too large, the CLVD provides the structure with stiffness as the main factor, followed by damping. Additionally, when the ratio of the displacement amplification factor to the geometric amplification factor satisfies fd/γ = 1/21−0.5α, the CLVD has the optimal displacement control effect on the structure. After that, measures are provided to optimize the CLVD in different situations in order to effectively control the inter-story displacement and the story shear force of the structure. Consequently, a nine-story frame is taken as an example to elaborate the application of CLVDs in the design for energy dissipation and vibration reduction. The results reveal that the CLVD scheme adopting the proposed optimization method can effectively enhance the displacement amplification ability of CLVDs, resulting in an additional damping ratio of up to 12%. At the same time, the inter-story displacement was reduced by almost 40% under fortification earthquakes. Through the research in this study, designers can obtain a new choice in structural vibration reduction design.

12 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
KWKeChuan Wu
KeChuan Wu
GWGuanglan Wei
Guanglan Wei
LZLongfei Zhang
Longfei Zhang
WYWenzheng Yu
Wenzheng Yu
LXLAN Xiang
LAN Xiang
Three all-steel buckling-restrained brace (ABRB) specimens without unbonded materials were designed and manufactured. Through low-cycle reciprocating load tests, the seismic performance of these buckling-restrained braces was investigated, and the influence of the absence of an unbonded layer on failure modes, energy dissipation capacity, and low-cycle fatigue life was examined. The research findings suggest that in all-steel buckling-restrained braces lacking an unbonded layer, the excessive friction between the energy dissipation unit and the restraining unit can, to a certain degree, increase local compressive stress. This makes the braces more susceptible to local buckling at the ends. The frictional effect causes the axial force of the ABRB to follow a distribution pattern where it is greater at the ends and smaller in the middle. Correspondingly, the buckling wavelength of the energy dissipation unit shows a pattern of being shorter at the ends and longer in the middle, which also results in a significant cyclic hardening phenomenon in the ABRB. The fatigue performance of the ABRB is inversely related to the amplitude of local buckling in the energy dissipation unit.