Alexander Podgorsak

Dr. Alexander Podgorsak


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2019 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
APAlexander Podgorsak
Alexander Podgorsak
RRRyan A Rava
Ryan A Rava
MBMohammad Mahdi Shiraz Bhurwani
Mohammad Mahdi Shiraz Bhurwani
ACAnusha R Chandra
Anusha R Chandra
JDJason M Davies
Jason M Davies
CICiprian N Ionita
Ciprian N Ionita
Background Angiographic parametric imaging (API) is an imaging method that uses digital subtraction angiography (DSA) to characterize contrast media dynamics throughout the vasculature. This requires manual placement of a region of interest over a lesion (eg, an aneurysm sac) by an operator. Objective The purpose of our work was to determine if a convolutional neural network (CNN) was able to identify and segment the intracranial aneurysm (IA) sac in a DSA and extract API radiomic features with minimal errors compared with human user results. Methods Three hundred and fifty angiographic images of IAs were retrospectively collected. The IAs and surrounding vasculature were manually contoured and the masks put to a CNN tasked with semantic segmentation. The CNN segmentations were assessed for accuracy using the Dice similarity coefficient (DSC) and Jaccard index (JI). Area under the receiver operating characteristic curve (AUROC) was computed. API features based on the CNN segmentation were compared with the human user results. Results The mean JI was 0.823 (95% CI 0.783 to 0.863) for the IA and 0.737 (95% CI 0.682 to 0.792) for the vasculature. The mean DSC was 0.903 (95% CI 0.867 to 0.937) for the IA and 0.849 (95% CI 0.811 to 0.887) for the vasculature. The mean AUROC was 0.791 (95% CI 0.740 to 0.817) for the IA and 0.715 (95% CI 0.678 to 0.733) for the vasculature. All five API features measured inside the predicted masks were within 18% of those measured inside manually contoured masks. Conclusions CNN segmentation of IAs and surrounding vasculature from DSA images is non-inferior to manual contours of aneurysms and can be used in parametric imaging procedures.

10 December 2019 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
MBMohammad Mahdi Shiraz Bhurwani
Mohammad Mahdi Shiraz Bhurwani
MWMuhammad Waqas
Muhammad Waqas
APAlexander Podgorsak
Alexander Podgorsak
KWKyle A Williams
Kyle A Williams
JDJason M Davies
Jason M Davies
CICiprian N Ionita
Ciprian N Ionita
Background Angiographic parametric imaging (API), based on digital subtraction angiography (DSA), is a quantitative imaging tool that may be used to extract contrast flow parameters related to hemodynamic conditions in abnormal pathologies such as intracranial aneurysms (IAs). Objective To investigate the feasibility of using deep neural networks (DNNs) and API to predict IA occlusion using pre- and post-intervention DSAs. Methods We analyzed DSA images of IAs pre- and post-treatment to extract API parameters in the IA dome and the corresponding main artery (un-normalized data). We implemented a two-step correction to account for injection variability (normalized data) and projection foreshortening (relative data). A DNN was trained to predict a binary IA occlusion outcome: occluded/unoccluded. Network performance was assessed with area under the receiver operating characteristic curve (AUROC) and classification accuracy. To evaluate the effect of the proposed corrections, prediction accuracy analysis was performed after each normalization step. Results The study included 190 IAs. The mean and median duration between treatment and follow-up was 9.8 and 8.0 months, respectively. For the un-normalized, normalized, and relative subgroups, the DNN average prediction accuracies for IA occlusion were 62.5% (95% CI 60.5% to 64.4%), 70.8% (95% CI 68.2% to 73.4%), and 77.9% (95% CI 76.2% to 79.6%). The average AUROCs for the same subgroups were 0.48 (0.44–0.52), 0.67 (0.61–0.73), and 0.77 (0.74–0.80). Conclusions The study demonstrated the feasibility of using API and DNNs to predict IA occlusion using only pre- and post-intervention angiographic information.

26 May 2020 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
RRRyan A Rava
Ryan A Rava
KSKenneth V Snyder
Kenneth V Snyder
MMMaxim Mokin
Maxim Mokin
MWMuhammad Waqas
Muhammad Waqas
XZXiaoliang Zhang
Xiaoliang Zhang
CICiprian N Ionita
Ciprian N Ionita
Background CT perfusion (CTP) infarct and penumbra estimations determine the eligibility of patients with acute ischemic stroke (AIS) for endovascular intervention. This study aimed to determine volumetric and spatial agreement of predicted RAPID, Vitrea, and Sphere CTP infarct with follow-up fluid attenuation inversion recovery (FLAIR) MRI infarct. Methods 108 consecutive patients with AIS and large vessel occlusion were included in the study between April 2019 and January 2020 . Patients were divided into two groups: endovascular intervention (n=58) and conservative treatment (n=50). Intervention patients were treated with mechanical thrombectomy and achieved successful reperfusion (Thrombolysis in Cerebral Infarction 2b/2 c/3) while patients in the conservative treatment group did not receive mechanical thrombectomy or intravenous thrombolysis. Intervention and conservative treatment patients were included to assess infarct and penumbra estimations, respectively. It was assumed that in all patients treated conservatively, penumbra converted to infarct. CTP infarct and penumbra volumes were segmented from RAPID, Vitrea, and Sphere to assess volumetric and spatial agreement with follow-up FLAIR MRI. Results Mean infarct differences (95% CIs) between each CTP software and FLAIR MRI for each cohort were: intervention cohort: RAPID=9.0±7.7 mL, Sphere=−0.2±8.7 mL, Vitrea=−7.9±8.9 mL; conservative treatment cohort: RAPID=−31.9±21.6 mL, Sphere=−26.8±17.4 mL, Vitrea=−15.3±13.7 mL. Overlap and Dice coefficients for predicted infarct were (overlap, Dice): intervention cohort: RAPID=(0.57, 0.44), Sphere=(0.68, 0.60), Vitrea=(0.70, 0.60); conservative treatment cohort: RAPID=(0.71, 0.56), Sphere=(0.73, 0.60), Vitrea=(0.72, 0.64). Conclusions Sphere proved the most accurate in patients who had intervention infarct assessment as Vitrea and RAPID overestimated and underestimated infarct, respectively. Vitrea proved the most accurate in penumbra assessment for patients treated conservatively although all software overestimated penumbra.

16 January 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
RRR.A. Rava
R.A. Rava
KSK.V. Snyder
K.V. Snyder
MMM. Mokin
M. Mokin
MWM. Waqas
M. Waqas
AAA.B. Allman
A.B. Allman
CIC.N. Ionita
C.N. Ionita
BACKGROUND AND PURPOSE: Brain CTP is used to estimate infarct and penumbra volumes to determine endovascular treatment eligibility for patients with acute ischemic stroke. We aimed to assess the accuracy of a Bayesian CTP algorithm in determining penumbra and final infarct volumes. MATERIALS AND METHODS: Data were retrospectively collected for 105 patients with acute ischemic stroke (55 patients with successful recanalization [TICI 2b/2c/3] and large-vessel occlusions and 50 patients without interventions). Final infarct volumes were calculated using DWI and FLAIR 24 hours following CTP imaging. RAPID and the Vitrea Bayesian CTP algorithm (with 3 different settings) predicted infarct and penumbra volumes for comparison with final infarct volumes to assess software performance. Vitrea settings used different combinations of perfusion maps (MTT, TTP, CBV, CBF, delay time) for infarct and penumbra quantification. Patients with and without interventions were included for assessment of predicted infarct and penumbra volumes, respectively. RESULTS: RAPID and Vitrea default setting had the most accurate final infarct volume prediction in patients with interventions ([Spearman correlation coefficient, mean infarct difference] default versus FLAIR: [0.77, 4.1 mL], default versus DWI: [0.72, 4.7 mL], RAPID versus FLAIR: [0.75, 7.5 mL], RAPID versus DWI: [0.75, 6.9 mL]). Default Vitrea and RAPID were the most and least accurate in determining final infarct volume for patients without an intervention, respectively (default versus FLAIR: [0.76, –0.4 mL], default versus DWI: [0.71, –2.6 mL], RAPID versus FLAIR: [0.68, −49.3 mL], RAPID versus DWI: [0.65, –51.5 mL]). CONCLUSIONS: Compared with RAPID, the Vitrea default setting was noninferior for patients with interventions and superior in penumbra estimation for patients without interventions as indicated by mean infarct differences and correlations with final infarct volumes.

13 June 2025 in Cancers
Verified
Journal Article
Open access
PDF file
MWMatthew Webster
Matthew Webster
APAlexander Podgorsak
Alexander Podgorsak
FLFiona Li
Fiona Li
YZYuwei Zhou
Yuwei Zhou
HJHyun Jung
Hyun Jung
DZDandan Zheng
Dandan Zheng
Radiotherapy (RT) has undergone transformative advancements since its inception over a century ago. This review highlights the most promising and impactful innovations shaping the current and future landscape of RT. Key technological advances include adaptive radiotherapy (ART), which tailors treatment to daily anatomical changes using integrated imaging and artificial intelligence (AI), and advanced image guidance systems, such as MR-LINACs, PET-LINACs, and surface-guided radiotherapy (SGRT), which enhance targeting precision and minimize collateral damage. AI and data science further support RT through automation, improved segmentation, dose prediction, and treatment planning. Emerging biological and targeted therapies, including boron neutron capture therapy (BNCT), radioimmunotherapy, and theranostics, represent the convergence of molecular targeting and radiotherapy, offering personalized treatment strategies. Particle therapies, notably proton and heavy ion RT, exploit the Bragg peak for precise tumor targeting while reducing normal tissue exposure. FLASH RT, delivering ultra-high dose rates, demonstrates promise in sparing normal tissue while maintaining tumor control, though clinical validation is ongoing. Spatially fractionated RT (SFRT), stereotactic techniques and brachytherapy are evolving to treat challenging tumor types with enhanced conformality and efficacy. Innovations such as 3D printing, Auger therapy, and hyperthermia are also contributing to individualized and site-specific solutions. Across these modalities, the integration of imaging, AI, and novel physics and biology-driven approaches is redefining the possibilities of cancer treatment. This review underscores the multidisciplinary and translational nature of modern RT, where physics, engineering, biology, and informatics intersect to improve patient outcomes. While many approaches are in various stages of clinical adoption and investigation, their collective impact promises to redefine the therapeutic boundaries of radiation oncology in the coming decade.

3 February 2026 in Cancers
Verified
Journal Article
Open access
PDF file
DZDandan Zheng
Dandan Zheng
GHGuang Han
Guang Han
OLOlga Dona Maria Lemus
Olga Dona Maria Lemus
APAlexander Podgorsak
Alexander Podgorsak
MWMatthew Webster
Matthew Webster
JYJihyung Yoon
Jihyung Yoon
Boron neutron capture therapy (BNCT) is experiencing a global resurgence driven by advances in boron pharmacology, accelerator-based neutron sources, and molecular imaging-guided theranostics. BNCT produces high linear energy transfer particles with micrometer-range energy deposition, enabling cell-selective irradiation confined to boron-enriched tumor cells in a geometrically targeted region by the neutron beam. This mechanism offers the potential for exceptionally high therapeutic ratios, provided two core requirements are met: sufficient differential tumor uptake of 10B and a neutron beam with appropriate energy and penetration. After early clinical attempts in the mid-20th century were hindered by inadequate boron agents and reactor-based neutron beams, recent technological breakthroughs have made BNCT clinically viable. The development of hospital-compatible accelerator neutron sources, next-generation boron delivery systems (such as receptor-targeted compounds and nanoparticles), advanced theranostic approaches (such as 18F-BPA positron emission tomography and boron-sensitive magnetic resonance imaging), and AI-driven biodistribution modeling now support personalized treatment planning and patient selection. These innovations have catalyzed modern clinical implementation, exemplified by Japan’s regulatory approval of BNCT for recurrent head and neck cancer and the rapid expansion of clinical programs across Asia, Europe, and South America. Building on these foundations, BNCT has transitioned from a predominantly academic experimental modality into an increasingly commercialized and industrially supported therapeutic platform. The emergence of dedicated BNCT companies, international collaborations between accelerator manufacturers and hospitals, and pharmaceutical development pipelines for next-generation boron carriers has accelerated clinical translation. Moreover, BNCT now occupies a unique position among radiation modalities due to its hybrid nature, namely combining the biological targeting of radiopharmaceutical therapy with the external-beam controllability of radiotherapy, thereby offering new therapeutic opportunities where competitive approaches fall short. Emerging evidence suggests therapeutic promise in glioblastoma, recurrent head and neck cancers, melanoma, meningioma, lung cancer, sarcomas, and other difficult-to-treat malignancies. Looking ahead, continued innovation in compact neutron source engineering, boron nanocarriers, multimodal theranostics, microdosimetry-guided treatment planning, and combination strategies with systemic therapies such as immunotherapy will be essential for optimizing outcomes. Together, these converging developments position BNCT as a biologically targeted and potentially transformative modality in the era of precision oncology.