HALIL IBRAHIM ULUSOY

Prof. HALIL IBRAHIM ULUSOY

Cumhuriyet University, Faculty of Pharmacy, Department of Analytical Chemistry, Sivas, TURKEY
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Separations
Verified
Journal Article
Open access
PDF file
Abuzar KabirAbuzar Kabir
Abuzar Kabir
Marcello LocatelliMarcello Locatelli
Marcello Locatelli
HALIL IBRAHIM ULUSOYHALIL IBRAHIM ULUSOY
HALIL IBRAHIM ULUSOY
Sample preparation has been recognized as a major step in the chemical analysis workflow. As such, substantial efforts have been made in recent years to simplify the overall sample preparation process. Major focusses of these efforts have included miniaturization of the extraction device; minimizing/eliminating toxic and hazardous organic solvent consumption; eliminating sample pre-treatment and post-treatment steps; reducing the sample volume requirement; reducing extraction equilibrium time, maximizing extraction efficiency etc. All these improved attributes are congruent with the Green Analytical Chemistry (GAC) principles. Classical sample preparation techniques such as solid phase extraction (SPE) and liquid-liquid extraction (LLE) are being rapidly replaced with emerging miniaturized and environmentally friendly techniques such as Solid Phase Micro Extraction (SPME), Stir bar Sorptive Extraction (SBSE), Micro Extraction by Packed Sorbent (MEPS), Fabric Phase Sorptive Extraction (FPSE), and Dispersive Liquid-Liquid Micro Extraction (DLLME). In addition to the development of many new generic extraction sorbents in recent years, a large number of molecularly imprinted polymers (MIPs) created using different template molecules have also enriched the large cache of microextraction sorbents. Application of nanoparticles as high-performance extraction sorbents has undoubtedly elevated the extraction efficiency and method sensitivity of modern chromatographic analyses to a new level. Combining magnetic nanoparticles with many microextraction sorbents has opened up new possibilities to extract target analytes from sample matrices containing high volumes of matrix interferents. The aim of the current review is to critically audit the progress of microextraction techniques in recent years, which has indisputably transformed the analytical chemistry practices, from biological and therapeutic drug monitoring to the environmental field; from foods to phyto-pharmaceutical applications.

1 August 2021 in Talanta
Verified
Journal Article
Closed access
BVBusra Vuran
Busra Vuran
HALIL IBRAHIM ULUSOYHALIL IBRAHIM ULUSOY
HALIL IBRAHIM ULUSOY
GSGokhan Sarp
Gokhan Sarp
EYErkan Yilmaz
Erkan Yilmaz
UPUMMUGULSUM POLAT
UMMUGULSUM POLAT
MSMUSTAFA SOYLAK
MUSTAFA SOYLAK

6 May 2023 in Advances in Sample Preparation
Verified
Journal Article
Open access
Marcello LocatelliMarcello Locatelli
Marcello Locatelli
Abuzar KabirAbuzar Kabir
Abuzar Kabir
MPMiryam Perrucci
Miryam Perrucci
SUSongül Ulusoy
Songül Ulusoy
HALIL IBRAHIM ULUSOYHALIL IBRAHIM ULUSOY
HALIL IBRAHIM ULUSOY
IAImran Ali
Imran Ali


20 January 2021 in Analytical Chemistry
Verified
Journal Article
Open access
Marcello LocatelliMarcello Locatelli
Marcello Locatelli
ATAngela Tartaglia
Angela Tartaglia
HALIL IBRAHIM ULUSOYHALIL IBRAHIM ULUSOY
HALIL IBRAHIM ULUSOY
SUSongul Ulusoy
Songul Ulusoy
FSFabio Savini
Fabio Savini
Abuzar KabirAbuzar Kabir
Abuzar Kabir
This study introduces an innovative device for the noninvasive sampling and chromatographic analysis of different compounds present in exhaled breath aerosol (EBA). The new sampling device, especially in light of the recent COVID-19 pandemic that forced many countries to impose mandatory facemasks, allows an easy monitoring of the subject’s exposure to different compounds they may come in contact with, actively or passively. The project combines the advantages of a fabric-phase sorptive membrane (FPSM) as an in vivo sampling device with a validated LC-MS/MS screening procedure able to monitor more than 739 chemicals with an overall analysis time of 18 min. The project involves the noninvasive in vivo sampling of the EBA using an FPSM array inserted inside an FFP2 mask. The study involved 15 healthy volunteers, and no restrictions were imposed during or prior to the sampling process regarding the consumption of drinks, food, or drugs. The FPSM array-LC-MS/MS approach allowed us to effectively exploit the advantages of the two complementary procedures (the convenient sampling by an FPSM array and the rapid analysis by LC-MS/MS), obtaining a powerful and green tool to carry out rapid screening analyses for human exposure to different compounds. The flexible fabric substrate, the sponge-like porous architecture of the high-efficiency sol–gel sorbent coating, the availability of a large cache of sorbent coatings, including polar, nonpolar, mixed mode, and zwitterionic phases, the easy installation into the facemask, and the possibility of sampling without interrupting regular activities provide FPSMs unparalleled advantages over other sampling techniques, and their applications are expected to expand to many other clinical or toxicological studies.

1 September 2017 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
SŞSelçuk Şimşek
Selçuk Şimşek
ZŞZeynep Mine Şenol
Zeynep Mine Şenol
HALIL IBRAHIM ULUSOYHALIL IBRAHIM ULUSOY
HALIL IBRAHIM ULUSOY