Kevin Vernooy

Prof. Dr. Kevin Vernooy

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in European Heart Journal
Verified
Journal Article
Open access
PDF file
MJMarek Jastrzębski
Marek Jastrzębski
GKGrzegorz Kiełbasa
Grzegorz Kiełbasa
ÓCÓscar Cano
Óscar Cano
KCKarol Curila
Karol Curila
LHLuuk Heckman
Luuk Heckman
KVKevin Vernooy
Kevin Vernooy
Aims: Permanent transseptal left bundle branch area pacing (LBBAP) is a promising new pacing method for both bradyarrhythmia and heart failure indications. However, data regarding safety, feasibility and capture type are limited to relatively small, usually single centre studies. In this large multicentre international collaboration, outcomes of LBBAP were evaluated. Methods and results: This is a registry-based observational study that included patients in whom LBBAP device implantation was attempted at 14 European centres, for any indication. The study comprised 2533 patients (mean age 73.9 years, female 57.6%, heart failure 27.5%). LBBAP lead implantation success rate for bradyarrhythmia and heart failure indications was 92.4% and 82.2%, respectively. The learning curve was steepest for the initial 110 cases and plateaued after 250 cases. Independent predictors of LBBAP lead implantation failure were heart failure, broad baseline QRS and left ventricular end-diastolic diameter. The predominant LBBAP capture type was left bundle fascicular capture (69.5%), followed by left ventricular septal capture (21.5%) and proximal left bundle branch capture (9%). Capture threshold (0.77 V) and sensing (10.6 mV) were stable during mean follow-up of 6.4 months. The complication rate was 11.7%. Complications specific to the ventricular transseptal route of the pacing lead occurred in 209 patients (8.3%). Conclusions: LBBAP is feasible as a primary pacing technique for both bradyarrhythmia and heart failure indications. Success rate in heart failure patients and safety need to be improved. For wider use of LBBAP, randomized trials are necessary to assess clinical outcomes.

28 August 2021 in European Heart Journal
Verified
Journal Article
Closed access
PDF file
MBMichele Brignole
Michele Brignole
FPFrancesco Pentimalli
Francesco Pentimalli
PPPietro Palmisano
Pietro Palmisano
MLMaurizio Landolina
Maurizio Landolina
FQFabio Quartieri
Fabio Quartieri
FIfor the APAF-CRT Trial Investigators
for the APAF-CRT Trial Investigators
In patients with atrial fibrillation (AF) and heart failure (HF), strict and regular rate control with atrioventricular junction ablation and biventricular pacemaker (Ablation + CRT) has been shown to be superior to pharmacological rate control in reducing HF hospitalizations. However, whether it also improves survival is unknown. In this international, open-label, blinded outcome trial, we randomly assigned patients with severely symptomatic permanent AF >6 months, narrow QRS (≤110 ms) and at least one HF hospitalization in the previous year to Ablation + CRT or to pharmacological rate control. We hypothesized that Ablation + CRT is superior in reducing the primary endpoint of all-cause mortality. A total of 133 patients were randomized. The mean age was 73 ± 10 years, and 62 (47%) were females. The trial was stopped for efficacy at interim analysis after a median of 29 months of follow-up per patient. The primary endpoint occurred in 7 patients (11%) in the Ablation + CRT arm and in 20 patients (29%) in the Drug arm [hazard ratio (HR) 0.26, 95% confidence interval (CI) 0.10–0.65; P = 0.004]. The estimated death rates at 2 years were 5% and 21%, respectively; at 4 years, 14% and 41%. The benefit of Ablation + CRT of all-cause mortality was similar in patients with ejection fraction (EF) ≤35% and in those with >35%. The secondary endpoint combining all-cause mortality or HF hospitalization was significantly lower in the Ablation + CRT arm [18 (29%) vs. 36 (51%); HR 0.40, 95% CI 0.22–0.73; P = 0.002]. Ablation + CRT was superior to pharmacological therapy in reducing mortality in patients with permanent AF and narrow QRS who were hospitalized for HF, irrespective of their baseline EF. ClinicalTrials.gov Identifier: NCT02137187.

28 March 2025 in EP Europace
Verified
Journal Article
Open access
MGMichael Glikson
Michael Glikson
HBHaran Burri
Haran Burri
AAAmr Abdin
Amr Abdin
ÓCÓscar Cano
Óscar Cano
KCkarol curila
karol curila
NVNiraj Varma
Niraj Varma
Conduction system pacing (CSP) is being increasingly adopted as a more physiological alternative to right ventricular and biventricular pacing. Since the 2021 European Society of Cardiology pacing guidelines, there has been growing evidence that this therapy is safe and effective. Furthermore, left bundle branch area pacing was not covered in these guidelines due to limited evidence at that time. This Clinical Consensus Statement provides advice on indications for CSP, taking into account the significant evolution in this domain.

1 March 2016 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
MMMasih Mafi-Rad
Masih Mafi-Rad
JLJustin G.L.M. Luermans
Justin G.L.M. Luermans
YBYuri Blaauw
Yuri Blaauw
MJMichel Janssen
Michel Janssen
HCHarry J. Crijns
Harry J. Crijns
KVKevin Vernooy
Kevin Vernooy
Background—: Left ventricular septal (LVS) pacing reduces ventricular dyssynchrony and improves cardiac function relative to right ventricular apex (RVA) pacing in animals. We aimed to establish permanent placement of an LVS pacing lead in patients using a transvenous approach through the interventricular septum. Methods and Results—: Ten patients with sinus node dysfunction scheduled for dual-chamber pacemaker implantation were prospectively enrolled. A custom pacing lead with extended helix was introduced via the left subclavian vein and, after positioning against the right ventricular septum (RVS) using a preshaped guiding catheter, driven through the interventricular septum to the LVS. The acute hemodynamic effect of RVA, RVS, and LVS pacing was evaluated by invasive LVdP/dtmax measurements. The lead was successfully delivered to the LVS in all patients. Procedure time and fluoroscopy time shortened with experience. QRS duration was shorter during LVS pacing (144±20 ms) than during RVA (172±33 ms; P =0.02 versus LVS) and RVS pacing (165±17 ms; P =0.004 versus LVS). RVA and RVS pacing reduced LVdP/dtmax compared with baseline atrial pacing (−7.1±4.1% and −6.9±4.3%, respectively), whereas LVS pacing maintained LVdP/dtmax at baseline level (1.0±4.3%; P =0.001 versus RVA and RVS). R-wave amplitude and pacing threshold were 12.2±6.7 mV and 0.5±0.2 V at implant and remained stable during 6-month follow-up without lead-related complications. Conclusions—: Permanent placement of an LVS pacing lead by transvenous approach through the interventricular septum is feasible in patients. LVS pacing preserves acute left ventricular pump function. This new pacing method could serve as an alternative and hemodynamically preferable approach for antibradycardia pacing.

30 March 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
Dominik LinzDominik Linz
Dominik Linz
JAJason G Andrade
Jason G Andrade
Elena ArbeloElena Arbelo
Elena Arbelo
Giuseppe BorianiGiuseppe Boriani
Giuseppe Boriani
GBGuenter Breithardt
Guenter Breithardt
PKPaulus Kirchhof
Paulus Kirchhof
Aims: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). Methods and results: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. Conclusions: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.

6 October 2022 in European Heart Journal
Verified
Journal Article
Open access
PDF file
RKReinoud E Knops
Reinoud E Knops
SPShari Pepplinkhuizen
Shari Pepplinkhuizen
PDPeter Paul H M Delnoy
Peter Paul H M Delnoy
LBLucas V A Boersma
Lucas V A Boersma
JKJuergen Kuschyk
Juergen Kuschyk
LNLouise R A Olde Nordkamp
Louise R A Olde Nordkamp
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice. Shown is the summary of the main endpoints of the manuscript: device-related complications in the subcutaneous and transvenous ICD: a secondary analysis of the PRAETORIAN trial. ICD, implantable cardioverter-defibrillator.