Hualiang Zhou

Hualiang Zhou


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2024 in IEEE Access
Verified
Journal Article
Open access
HZHualiang Zhou
Hualiang Zhou
LLLu Lu
Lu Lu
GWGaoming Wang
Gaoming Wang
ZSZhantao Su
Zhantao Su
With the rapid development of digital operation and maintenance of transformers, the interference of abnormal data caused by the low reliability of online monitoring sensors has become increasingly evident, directly affecting the accuracy of transformer fault diagnosis and impacting the development of digital operation and maintenance of transformers. Therefore, detecting abnormal data and distinguishing whether abnormal data are caused by equipment faults is an important prerequisite for the accurate diagnosis of transformers. When the difference between normal and abnormal data from online monitoring is insignificant, the existing methods are not ideal for detecting abnormal transformer data and cannot determine invalid data caused by sensor failure. To accurately identify valid data and remove invalid data, this study proposes a combined association rule and improved density clustering method to detect abnormalities in the online monitoring data of transformers. First, association rules mimic the association relationships between transformer data sequences. Then, the association rules are combined with an improved density clustering method based on the number of categories–neighborhood radius threshold curve–to detect anomalies in the sequences. Finally, the accurate identification of abnormal data is achieved, and invalid data caused by sensor reasons are effectively screened, thereby screening valuable data generated by transformer faults. The test results indicate that the proposed method can effectively improve the accuracy and stability of abnormal data detection in online monitoring of transformers.

26 March 2024 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
LJLong Jin
Long Jin
ZZZexin Zhou
Zexin Zhou
HZHualiang Zhou
Hualiang Zhou
YSYi Su
Yi Su
JMJiangwen Meng
Jiangwen Meng
A significant difference exists between high-altitude electromagnetic pulse (HEMP) and the electromagnetic interference generated by the substation. Analyzing the immunity of relay protection equipment under HEMP is significant. First, a finite element simulation model of electromagnetic field was established based on the physical structure of typical relay protection equipment. Second, changing the polarization direction and incidence angle of HEMP, simulated and analyzed the electric field distribution characteristics of relay protection equipment boards under different working conditions. Third, simulated the field strength distribution characteristics on the selected path of the board of the equipment with a heat dissipation hole on the top of the chassis. Besides, compared and analyzed the differences in the distribution of electric fields inside equipment boards under the radiated electromagnetic fields and HEMPs. Finally, the induced voltage magnitude of the vital port of the board under HEMP excitation and the susceptibility of relay protection equipment in dealing with HEMP and cable coupling interference signals were verified through the experiment. This work is of great significance for analyzing the electromagnetic compatibility characteristics of relay protection equipment under HEMPs.

22 December 2023 in Electronics
Verified
Journal Article
Open access
PDF file
HZHualiang Zhou
Hualiang Zhou
余昊余 昊
余 昊
ZZZhiyang Zou
Zhiyang Zou
ZSZhantao Su
Zhantao Su
QZQianyun Zhao
Qianyun Zhao
CHChaohui He
Chaohui He
Traditionally, studies have primarily focused on single event effects in aerospace electronics. However, current research has confirmed that atmospheric neutrons can also induce single event effects in China’s advanced technology relay protection devices. Spallation neutron irradiation tests on a Loongson 2K1000 system-on-chip based relay protection device have revealed soft errors, including abnormal sampling, refusal of operation and interlock in the relay protection device. Given the absence of standardized evaluation methods for single event effects on relay protection devices, the following research emphasizes the use of Monte Carlo simulation and software fault injection. Various types of single event upsets, such as single bit upsets, dual bit upsets, and even eight bit upsets, were observed in Monte Carlo simulations where atmospheric neutrons hit the chip from different directions (top and bottom). The simulation results indicated that the single event effect sensitivity of the relay protection device was similar whether the neutron hit from the top or the bottom. Through software fault injection, the study also identified soft errors caused by neutron induced single event upsets on the Loongson 2K1000 system, including failure to execute, system halt, time out, and error result. And the soft error number of system halts and error results exceeded that of time outs and failures to execute in all three tested programs. This research represents a preliminary assessment of single event effects on relay protection devices and is expected to provide valuable insights for evaluating the reliability of advanced technology relay protection devices.

19 August 2021 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
HZHualiang Zhou
Hualiang Zhou
YZYuping Zheng
Yuping Zheng
JXJiansong Xu
Jiansong Xu
YLYoujun Li
Youjun Li
JCJiaxi Cao
Jiaxi Cao
Relay protection devices based on sampling and tripping over shared networks, including the switch tree network and high-availability seamless redundancy ring network, have been widely used in smart substations. These networks all have uncertainties in the relay operation system, such as data congestion, delays, errors, and storms, etc., leading errors to sampled value (SV) in digital protection. Therefore, the effective delay measurement and evaluation method over shared networks are important for the reliable relay operation. Based on the principle and implementation of SV propagation delay measurement in shared network, a novel evaluation method of propagation delay measurement is proposed in this article. With this method, the credibility of the delay measurement could be evaluated and the threshold of delay could be adjusted flexibly in engineering. The credibility indicator and engineering threshold method could mitigate spurious tripping and improve the reliable operation in the protection system.

8 January 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
HZHualiang Zhou
Hualiang Zhou
余昊余 昊
余 昊
ZZZhiyang Zou
Zhiyang Zou
ZSZhantao Su
Zhantao Su
ZXZheng Xu
Zheng Xu
CHChaohui He
Chaohui He
Relay protection devices must operate continuously throughout the year without anomalies. With the integration of advanced technology and process chips in secondary equipment, new risks need to be addressed to ensure the reliability of these relay protection devices. One such risk is the impact of α-particles inducing single event effects (SEEs) on the secondary equipment. To date, there has been limited assessment of the effects of α-particles on relay protection devices from a system perspective. This study evaluates the impact of SEE on relay protection devices through a Monte Carlo simulation, which is verified by α-particle radiation, fault injection, and fault tree analysis. It discusses the influence of SEEs with and without hardening measures in place. Additionally, this study examines the soft error probability when the target processor runs both general workloads and specific application workloads. The current research proposes a low-cost and effective reliability assessment method for secondary equipment considering single event effects. The findings provide new insights for the enhancement of future electric power grid systems.

11 October 2024 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YHYinlong Hu
Yinlong Hu
XCXuhao Cai
Xuhao Cai
CCChangjun Cheng
Changjun Cheng
SSShang Shi
Shang Shi
Haiping DuHaiping Du
Haiping Du
HZHualiang Zhou
Hualiang Zhou
In this article, we present a prescribed-time state and extended disturbance observer with finite time-varying gains (PTFG-SEDO) for normal-form systems experiencing matched unknown disturbances. By extending the traditional prescribed-time state observer with finite time-varying gains (PTFG-SO), simultaneous estimation of states, disturbances, and their derivatives has been achieved. The main motivation of this article is to further improve the state estimation performance of the existing PTFG-SO by complementing it with disturbance estimation and compensation in the proposed PTFG-SEDO. Furthermore, the estimated disturbance information can be utilized in disturbance observer-based control algorithms. The proposed PTFG-SEDO is effectively integrated into an active vibration isolation system, within which a pair of absolute velocity feedback control laws, based on the PTFG-SEDO, are meticulously developed and juxtaposed with their traditional PTFG-SO-based counterparts. The experimental findings reveal that the fast and precise disturbance estimation afforded by the PTFG-SEDO facilitates the efficacious neutralization of the constant components of disturbances. Moreover, the enhanced precision in state estimation is demonstrated to contribute significantly to the refinement of the sinusoidal components of the vibrations.