10 February 2020 in Pediatric Anesthesia
26 March 2024 in IEEE Transactions on Plasma Science
A significant difference exists between high-altitude electromagnetic pulse (HEMP) and the electromagnetic interference generated by the substation. Analyzing the immunity of relay protection equipment under HEMP is significant. First, a finite element simulation model of electromagnetic field was established based on the physical structure of typical relay protection equipment. Second, changing the polarization direction and incidence angle of HEMP, simulated and analyzed the electric field distribution characteristics of relay protection equipment boards under different working conditions. Third, simulated the field strength distribution characteristics on the selected path of the board of the equipment with a heat dissipation hole on the top of the chassis. Besides, compared and analyzed the differences in the distribution of electric fields inside equipment boards under the radiated electromagnetic fields and HEMPs. Finally, the induced voltage magnitude of the vital port of the board under HEMP excitation and the susceptibility of relay protection equipment in dealing with HEMP and cable coupling interference signals were verified through the experiment. This work is of great significance for analyzing the electromagnetic compatibility characteristics of relay protection equipment under HEMPs.
10 August 2023 in IEEE Access
Effective thermal management measures are of great significance for improving the reliability of relay protection equipment. Firstly, the paper establishes a temperature calculation function for components based on the thermal superposition model, calculates the minimum heat dissipation distance between components, and converts the functional coordination of components into coordinate constraints. An optimised layout scheme for components is obtained quickly based on the minimum heat dissipation distance and coordinate constraints. The finite element simulation results show that the optimized layout significantly improves the temperature of the components, with a maximum temperature reduction of 8.6%. Then a component overheating warning strategy has been proposed based on state recognition. By monitoring the operating temperature of the components, the life accelerated decay ratio of the components is calculated, and the allowable operating time and alarm signal of the components at a specific temperature are combined to accurately reflect the operating status of the components.
10 June 2026 in High Voltage
High altitude electromagnetic pulse (HEMP), as a steep slope and high amplitude instantaneous energy shock, has stronger coupling and greater destructive power, which can easily cause the secondary control device of the substation to malfunction. In order to explore the anti‐interference ability of the relay protection device to HEMP, a simulation model of electromagnetic radiation based on the actual physical structure was built, and the distribution characteristics of the electric field inside the device were explored under the influence of different excitation factors such as HEMP amplitude, incident angle, and polarisation direction. A radiation and conduction coupling test platform was built between the device and HEMP, and the HEMP threshold of the device malfunctioning due to radiated coupling interference was obtained by comparing the changes in the action characteristics of the device facing the same fault before and after irradiation. The tolerance of the device’s power port under HEMP‐conducted interference is verified. The test results show that when the peak irradiation of HEMP reaches 35 kV/m, the device begins to malfunction, and the tripping time in the face of the same fault is significantly prolonged. The operational reliability of relay protection devices is greatly reduced, which affects the safe and stable operation of the power grid.