jeff Wilcox christle

Dr. jeff Wilcox christle

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2012 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
Johannes ScherrJohannes Scherr
Johannes Scherr
BWBernd Wolfarth
Bernd Wolfarth
JCjeff Wilcox christle
jeff Wilcox christle
APAxel Pressler
Axel Pressler
SWStefan Wagenpfeil
Stefan Wagenpfeil
MHMartin Halle
Martin Halle

Verified
Journal Article
Open access
PDF file
ASAnna Shcherbina
Anna Shcherbina
CMC. Mikael Mattsson
C. Mikael Mattsson
DWDaryl Waggott
Daryl Waggott
HSHeidi Salisbury
Heidi Salisbury
JCjeff Wilcox christle
jeff Wilcox christle
EAEuan A. Ashley
Euan A. Ashley
The ability to measure physical activity through wrist-worn devices provides an opportunity for cardiovascular medicine. However, the accuracy of commercial devices is largely unknown. The aim of this work is to assess the accuracy of seven commercially available wrist-worn devices in estimating heart rate (HR) and energy expenditure (EE) and to propose a wearable sensor evaluation framework. We evaluated the Apple Watch, Basis Peak, Fitbit Surge, Microsoft Band, Mio Alpha 2, PulseOn, and Samsung Gear S2. Participants wore devices while being simultaneously assessed with continuous telemetry and indirect calorimetry while sitting, walking, running, and cycling. Sixty volunteers (29 male, 31 female, age 38 ± 11 years) of diverse age, height, weight, skin tone, and fitness level were selected. Error in HR and EE was computed for each subject/device/activity combination. Devices reported the lowest error for cycling and the highest for walking. Device error was higher for males, greater body mass index, darker skin tone, and walking. Six of the devices achieved a median error for HR below 5% during cycling. No device achieved an error in EE below 20 percent. The Apple Watch achieved the lowest overall error in both HR and EE, while the Samsung Gear S2 reported the highest. In conclusion, most wrist-worn devices adequately measure HR in laboratory-based activities, but poorly estimate EE, suggesting caution in the use of EE measurements as part of health improvement programs. We propose reference standards for the validation of consumer health devices (http://precision.stanford.edu/).

28 February 2017 in Circulation
Verified
Journal Article
Open access
PDF file
ØEØyvind Ellingsen
Øyvind Ellingsen
MHMartin Halle
Martin Halle
VCViviane Conraads
Viviane Conraads
ASAsbjørn Støylen
Asbjørn Støylen
HDHavard Dalen
Havard Dalen
ALAxel Linke
Axel Linke
Background: Small studies have suggested that high-intensity interval training (HIIT) is superior to moderate continuous training (MCT) in reversing cardiac remodeling and increasing aerobic capacity in patients with heart failure with reduced ejection fraction. The present multicenter trial compared 12 weeks of supervised interventions of HIIT, MCT, or a recommendation of regular exercise (RRE). Methods: Two hundred sixty-one patients with left ventricular ejection fraction ≤35% and New York Heart Association class II to III were randomly assigned to HIIT at 90% to 95% of maximal heart rate, MCT at 60% to 70% of maximal heart rate, or RRE. Thereafter, patients were encouraged to continue exercising on their own. Clinical assessments were performed at baseline, after the intervention, and at follow-up after 52 weeks. Primary end point was a between-group comparison of change in left ventricular end-diastolic diameter from baseline to 12 weeks. Results: Groups did not differ in age (median, 60 years), sex (19% women), ischemic pathogenesis (59%), or medication. Change in left ventricular end-diastolic diameter from baseline to 12 weeks was not different between HIIT and MCT ( P =0.45); left ventricular end-diastolic diameter changes compared with RRE were −2.8 mm (−5.2 to −0.4 mm; P =0.02) in HIIT and −1.2 mm (−3.6 to 1.2 mm; P =0.34) in MCT. There was also no difference between HIIT and MCT in peak oxygen uptake ( P =0.70), but both were superior to RRE. However, none of these changes was maintained at follow-up after 52 weeks. Serious adverse events were not statistically different during supervised intervention or at follow-up at 52 weeks (HIIT, 39%; MCT, 25%; RRE, 34%; P =0.16). Training records showed that 51% of patients exercised below prescribed target during supervised HIIT and 80% above target in MCT. Conclusions: HIIT was not superior to MCT in changing left ventricular remodeling or aerobic capacity, and its feasibility remains unresolved in patients with heart failure. Clinical Trial Registration: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00917046.

1 July 2017 in Progress in Cardiovascular Diseases
Verified
Journal Article
Closed access
JMJonathan Myers
Jonathan Myers
LKLeonard A. Kaminsky
Leonard A. Kaminsky
RLRICARDO LIMA
RICARDO LIMA
JCjeff Wilcox christle
jeff Wilcox christle
EAEuan Ashley
Euan Ashley
RARoss Arena
Ross Arena

24 March 2015 in Digestion
Verified
Journal Article
Closed access
PDF file
PKPeter Klare
Peter Klare
JNJohanna Nigg
Johanna Nigg
JNJohannes Nold
Johannes Nold
BHBernhard Haller
Bernhard Haller
AKAnne B. Krug
Anne B. Krug
WHWolfgang Huber
Wolfgang Huber
Background: Improving health-related quality of life is a primary target of therapy for patients with inflammatory bowel disease. Physical activity has been demonstrated to improve health-related quality of life in several patient populations with chronic disease. There are very few studies investigating the effects of physical activity on health-related quality of life in inflammatory bowel disease. The primary purpose of this study is to investigate the effects of 10 weeks of moderate physical activity on health-related quality of life in patients with inflammatory bowel disease. Methods: Thirty patients with mild to moderate IBD (Crohn‘s Disease Activity Index (CDAI) <220 or Rachmilewitz Index (RI) <11) were randomized 1:1 to either supervised moderate-intensity running thrice a week for 10 weeks or a control group who were not prescribed any exercise. Health-related quality of life, symptoms, and inflammation were assessed at baseline and after 10 weeks. Results: Participants were 41 ± 14 years (73% female), had a body mass index of 22.8 ± 4.1 kg/m2, and an average CDAI or RI of 66.8 ± 42.4 and 3.6 ± 3.1. No adverse events occurred during the 10-week training period. Health-related quality of life, reported as IBDQ total score, improved 19% in the intervention group and 8% in the control group. Scores for the IBDQ social sub-scale were significantly improved in the intervention group compared with controls (IBDQsocial = 6.27 ± 5.46 vs. 1.87 ± 4.76, p = 0.023). Conclusion: Patients suffering from moderately active IBD are capable of performing symptom-free regular endurance exercise. Our data support the assumption that PA is feasible in IBD patients. PA may furthermore improve quality of life through improvements in social well-being, and may, therefore, be a useful adjunct to IBD therapy.

1 January 2018 in Arrhythmia and Electrophysiology Review
Verified
Journal Article
Closed access
NSNikhil Singh
Nikhil Singh
KMKegan James Moneghetti
Kegan James Moneghetti
JCjeff Wilcox christle
jeff Wilcox christle
DHDavid Hadley
David Hadley
DPDaniel Plews
Daniel Plews
VFVictor Froelicher
Victor Froelicher
The autonomic nervous system plays a major role in optimising function of the cardiovascular (CV) system, which in turn has important implications for CV health. Heart rate variability (HRV) is a measurable reflection of this balance between sympathetic and parasympathetic tone and has been used as a marker for cardiac status and predicting CV outcomes. Recently, the availability of commercially available heart rate (HR) monitoring systems has had important CV health implications and permits ambulatory CV monitoring on a scale not achievable with traditional cardiac diagnostics. The focus of the first part of this two-part review is to summarise the physiology of HRV and to describe available technologies for HRV monitoring. Part two will present HRV measures for assessing CV prognosis and athletic training.