Hongzhuang Guo

Dr. Hongzhuang Guo


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
HGHongzhuang Guo
Hongzhuang Guo
XJXiuyan Jin
Xiuyan Jin
HZHao Zhang
Hao Zhang
PGPing Gong
Ping Gong
XWXin Wang
Xin Wang
TSTingting Sun
Tingting Sun
In addressing the detection of drug resistance in Helicobacter pylori, we have successfully developed an efficient and highly accurate detection methodology. Initially, we designed and fabricated a microarray chip, which underwent finite element analysis for its optical and thermal characteristics. Ultimately, COC material was chosen as the processing material for the chip, ensuring superior performance. Subsequently, we established a comprehensive detection system and validated its performance. Following that, comparative experiments were conducted for detecting drug resistance in H. pylori. The experimental results indicate that our established methodology aligns with the results obtained using the E-test detection kit, achieving a concordance rate of 100%. In comparison to the E-test detection kit, our methodology reduces the detection time to 1.5 h and provides a more extensive coverage of detection sites.

25 June 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
HGHongzhuang Guo
Hongzhuang Guo
HZHao Zhang
Hao Zhang
TSTingting Sun
Tingting Sun
XWXin Wang
Xin Wang
PGPing Gong
Ping Gong
Phosphate plays a crucial role in microbial proliferation, and the regulation of the phosphate concentration can modulate the fermentation efficiency. In this study, based on Lambert–Beer’s Law and the selective absorption characteristics of substances under light, a dual-light-type photoelectric colorimetric device for phosphate determination was designed. The device’s main components, such as the excitation light path and incubation stations, were modeled and simulated. The primary performance of the instrument was verified, and comparative experiments with a UV-1780 spectrophotometer were conducted to validate its performance. The experimental results demonstrate that this device exhibits a high degree of linearity with an R2 value of 0.9956 and a repeatability of ≤1.72%. The average temperature rise rate at the incubation stations was measured at 0.44 °C/s, with a temperature uniformity ≤ ±0.1 °C (temperature set at 37.3 °C). Consistently observed trends in the measurement of 23 CHO cell suspensions using the UV-1780 spectrophotometer further validated the accuracy and reliability of the device’s detection results.

18 August 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
HGHongzhuang Guo
Hongzhuang Guo
PGPing Gong
Ping Gong
TSTingting Sun
Tingting Sun
XWXin Wang
Xin Wang
HZHao Zhang
Hao Zhang
As of 31 October 2023, there have been 771,795,258 confirmed cases of COVID-19 globally. Developing simple, portable, and reliable testing devices has become increasingly important. This paper presents a point-of-care testing (POCT) device for COVID-19 based on the dual-excitation fluorescence RT-LAMP method, which is derived from the principles of RT-LAMP-based COVID-19 detection kits available in the market. The key design solutions of the device were simulated and modeled. Key performance metrics such as detection repeatability and linearity were validated. Comparative experiments with the RT-qPCR detection method were conducted to verify the accuracy and reliability of the device. Additionally, the device’s detection sensitivity and accuracy were assessed. Experimental results show that the repeatability coefficient of variation (CV) value is ≤0.09%; the linearity R2 for the FAM channel is 0.9977 and that for the HEX channel is 0.9899; it exhibits good anti-interference performance, with negligible cross-channel interference; the temperature stability is ±0.062 °C, the temperature accuracy is less than 0.2 °C, and there is no significant temperature overshoot during the heating process. Compared with the real-time quantitative PCR (RT-qPCR) instrument, the positive agreement rate is 100% and the negative agreement rate is 95.0%. This research provides a foundational basis for the development of equipment for the prevention of infectious diseases and clinical diagnostics.