Stirling Howieson

Dr. Stirling Howieson


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2009 in Allergy
Verified
Journal Article
Closed access
PDF file
GWG. R. Wright
G. R. Wright
SHStirling Howieson
Stirling Howieson
CMC. McSharry
C. McSharry
AMA. D. McMahon
A. D. McMahon
RCR. Chaudhuri
R. Chaudhuri
NTNeil C. Thomson
Neil C. Thomson

Tim SharpeTim Sharpe
Tim Sharpe
PFPaul Farren
Paul Farren
SHStirling Howieson
Stirling Howieson
PTPaul Tuohy
Paul Tuohy
JMJonathan McQuillan
Jonathan McQuillan
The need to reduce carbon emissions and fuel poverty has led to increased building envelope air tightness, intended to reduce uncontrolled ventilation heat losses. Ventilation strategies in dwellings still allow the use of trickle ventilators in window frames for background ventilation. The extent to which this results in “healthy” Indoor Air Quality (IAQ) in recently constructed dwellings was a concern of regulators in Scotland. This paper describes research to explore this. First a review of literature was conducted, then data on occupant interactions with ventilation provisions (windows, doors, trickle vents) gathered through an interview-based survey of 200 recently constructed dwellings, and measurements made on a sample of 40 of these. The main measured parameter discussed here is CO2 concentration. It was concluded after the literature review that 1000 ppm absolute was a reasonable threshold to use for “adequate” ventilation. The occupant survey found that there was very little occupant interaction with the trickle ventilators e.g., in bedrooms 63% were always closed, 28% always open, and in only 9% of cases occupants intervened to make occasional adjustments. In the measured dwellings average bedroom CO2 levels of 1520 ppm during occupied (night time) hours were observed. Where windows were open the average bedroom CO2 levels were 972 ppm. With windows closed, the combination of “trickle ventilators open plus doors open” gave an average of 1021 ppm. “Trickle ventilators open” gave an average of 1571 ppm. All other combinations gave averages of 1550 to 2000 ppm. Ventilation rates and air change rates were estimated from measured CO2 levels, for all dwellings calculated ventilation rate was less than 8 L/s/p, in 42% of cases calculated air change rate was less than 0.5 ach. It was concluded that trickle ventilation as installed and used is ineffective in meeting desired ventilation rates, evidenced by high CO2 levels reported across the sampled dwellings. Potential implications of the results are discussed.

1 January 2005 in Perspectives in Public Health
Verified
Journal Article
Closed access
PDF file
SHStirling Howieson
Stirling Howieson
MHM Hogan
M Hogan
The recent publication of the Scottish Index of Multiple Deprivation (SIMD) has allowed some tentative statistical correlations to be undertaken to assess the impact poverty may have on mortality and morbidity. During the period 1989 to 2001, Scotland registered around 51,600 excess winter deaths (EWDs). An EWD is taken as the additional deaths during December to March than occurred in the preceding and subsequent four-month periods. Almost all of these EWDs were in the population aged over 65. This represents 50 more deaths per day in January than in July. The SIMD measured five criteria by region: income; employment; health and disability; education, skills and training; and geographical access to services. Glasgow was the most deprived region with an SIMD score of 46.88 and East Dunbartonshire, the least deprived region, with a score of 9.07. For the over 65s, the chance of becoming an EWD in Glasgow is one in 36, rising to one in 68 for North Ayrshire. The SIMD is positively correlated with EWD by region (0.35 at the 5% confidence level). This correlation appears to go against the influence of climatic variations, house type, energy efficiency and access to the gas network which favours urban areas. Although some of the additional winter deaths have been ascribed to outdoor cold exposure - exacerbated by inappropriate clothing or culturally determined behaviour - the majority of EWDs are premature and essentially preventable if the elderly can be kept warm in their homes during the winter months.

16 April 2015 in Clinical & Experimental Allergy
Verified
Journal Article
Closed access
PDF file
CMC. McSharry
C. McSharry
SVS. Vesper
S. Vesper
LWL. Wymer
L. Wymer
SHStirling Howieson
Stirling Howieson
RCR. Chaudhuri
R. Chaudhuri
NTN. C. Thomson
N. C. Thomson

1 August 2003 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
SHStirling Howieson
Stirling Howieson
ALA Lawson
A Lawson
CMC McSharry
C McSharry
GMG Morris
G Morris
EME McKenzie
E McKenzie
JJJ Jackson
J Jackson
This paper is concerned with historical changes in domestic ventilation rates, relative humidity and the associated risk of house dust mite colonization. A controlled trial evaluated allergen and water vapour control measures on the level of house dust mite (HDM) Der p1 allergen and indoor humidity, concurrently with changes in lung function in 54 subjects who completed the protocol. Mechanical heat recovery ventilation units significantly reduced moisture content in the active group, while HDM allergen reservoirs in carpets and beds were reduced by circa 96%. Self reported health status confirmed a significant clinical improvement in the active group. The study can form the basis for assessing minimum winter ventilation rates that can suppress RH below the critical ambient equilibrium humidity of 60% and thus inhibit dust mite colonization and activity in temperate and maritime in‘ uenced climatic regions.

16 February 2005
Verified
Book
Closed access
PDF file
SHStirling Howieson
Stirling Howieson
Asthma is on the rise in a number of countries, in this volume Howieson asks what role the built environment has to play and what the construction industry can do to either slow the increase or reverse the trend. Based on the findings of a six-year research project, this book considers all aspects of housing to develop new strategies for dealing with the asthma pandemic in Britain and beyond. With the focus on the design and use pattern of our dwellings, the book looks at tackling the problems inherent in existing housing as well as forging guiding principles for the design of new dwellings, together with a financial assessment of the proposals.