Vascular calcifications in aorto-iliac arteries are emerging as crucial risk factors for cardiovascular diseases (CVDs) with profound clinical implications. This systematic review, following PRISMA guidelines, investigated methodologies for measuring these calcifications and explored their correlation with CVDs and clinical outcomes. Out of 698 publications, 11 studies met the inclusion criteria. In total, 7 studies utilized manual methods, while 4 studies utilized automated technologies, including artificial intelligence and deep learning for image analyses. Age, systolic blood pressure, serum calcium, and lipoprotein(a) levels were found to be independent risk factors for aortic calcification. Mortality from CVDs was correlated with abdominal aorta calcification. Patients requiring reintervention after endovascular recanalization exhibited a significantly higher volume of calcification in their iliac arteries. Conclusions: This review reveals a diverse landscape of measurement methods for aorto-iliac calcifications; however, they lack a standardized reproducibility assessment. Automatic methods employing artificial intelligence appear to offer broader applicability and are less time-consuming. Assessment of calcium scoring could be routinely employed during preoperative workups for risk stratification and detailed surgical planning. Additionally, its correlation with clinical outcomes could be useful in predicting the risk of reinterventions and amputations.
There is currently a shift in surgical training from traditional methods to simulation-based approaches, recognizing the necessity of more effective and controlled learning environments. This study introduces a completely new 3D-printed modular system for endovascular surgery training (M-SET), developed to allow various difficulty levels. Its design was based on computed tomography angiographies from real patient data with femoro-popliteal lesions. The study aimed to explore the integration of simulation training via a 3D model into the surgical training curriculum and its effect on their performance. Our preliminary study included 12 volunteer trainees randomized 1:1 into the standard simulation (SS) group (3 stepwise difficulty training sessions) and the random simulation (RS) group (random difficulty of the M-SET). A senior surgeon evaluated and timed the final training session. Feedback reports were assessed through the Student Satisfaction and Self-Confidence in Learning Scale. The SS group completed the training sessions in about half time (23.13 ± 9.2 min vs. 44.6 ± 12.8 min). Trainees expressed high satisfaction with the training program supported by the M-SET. Our 3D-printed modular training model meets the current need for new endovascular training approaches, offering a customizable, accessible, and effective simulation-based educational program with the aim of reducing the time required to reach a high level of practical skills.
We report a multicenter experience of open conversions (OC) for aortic endograft infections (AEI). We retrospectively analyzed all patients who underwent OC for AEI after endovascular aneurysm repair (EVAR), from 1997 to 2021 in 12 Italian centers. The endpoints were as follows: mortality (30-days, in-hospital), major postoperative complications. Follow-up data included: survival, aortic-related complications, infection persistence or reoccurrence. Fifty-eight patients (mean age: 73.8 ± 6.6 years) were included. Median time from EVAR to OC was 14 months (interquartile range 7–45). Thirty-five patients (60.3%) were symptomatic at presentation. Aortic reconstruction was anatomic in 32 patients (55.2%), extra-anatomic in 26 (44.8%). Thirty-day mortality was 31% (18/58). Six additional patients died after 30 days during the same hospitalization (in-hospital mortality: 41.4%). Most common post-operative complications included respiratory failure (38.6%) and renal insufficiency (35.1%). During 28.1 ± 4 months follow-up, 4 aneurysm-related deaths were recorded. Infection re-occurred in 29.4% of the patients. Estimated survival was 50% at 1 year, and 30% at 5 years, and was significantly lower for patients who underwent extra-anatomic reconstructions (37 vs 61% at 1 year, 16 vs 45% at 5 years; log-rank P = .021). OC for AEI is associated with high early mortality. The poor mid-term survival is influenced by aortic complications and infection re-occurrence.
Objectives: This study aims to develop and validate a standardized methodology for creating high-fidelity, custom-made, patient-specific 3D-printed vascular models that serve as tools for preoperative planning and training in the endovascular treatment of peripheral artery disease (PAD). Methods: Ten custom-made 3D-printed vascular models were produced using computed tomography angiography (CTA) scans of ten patients diagnosed with PAD. CTA images were analyzed using Syngo.via by a specialist to formulate a medical prescription that guided the model’s creation. The CTA data were then processed in OsiriX MD to generate the .STL file, which is further refined in a Meshmixer. Stereolithography (SLA) 3D printing technology was employed, utilizing either flexible or rigid materials. The dimensional accuracy of the models was evaluated by comparing their CT scan images with the corresponding patient data, using OsiriX MD. Additionally, both flexible and rigid models were evaluated by eight vascular surgeons during simulations in an in-house-designed setup, assessing both the technical aspects and operator perceptions of the simulation. Results: Each model took approximately 21.5 h to fabricate, costing €140 for flexible and €165 for rigid materials. Bland–Alman plots revealed a strong agreement between the 3D models and patient anatomy, with outliers ranging from 4.3% to 6.9%. Simulations showed that rigid models performed better in guidewire navigation and catheter stability, while flexible models offered improved transparency and lesion treatment. Surgeons confirmed the models’ realism and utility. Conclusions: The study highlights the cost-efficient, high-fidelity production of 3D-printed vascular models, emphasizing their potential to enhance training and planning in endovascular surgery.