Arianna Mersanne

Dr. Arianna Mersanne

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
ACAlexandra Catasta
Alexandra Catasta
Chiara MartiniChiara Martini
Chiara Martini
AMArianna Mersanne
Arianna Mersanne
Ruben ForestiRuben Foresti
Ruben Foresti
CMClaudio Bianchini Massoni
Claudio Bianchini Massoni
Paolo PeriniPaolo Perini
Paolo Perini
The use of 3D-printed models in simulation-based training and planning for vascular surgery is gaining interest. This study aims to provide an overview of the current applications of 3D-printing technologies in vascular surgery. We performed a systematic review by searching four databases: PubMed, Web of Science, Scopus, and Cochrane Library (last search: 1 March 2024). We included studies considering the treatment of vascular stenotic/occlusive or aneurysmal diseases. We included papers that reported the outcome of applications of 3D-printed models, excluding case reports or very limited case series (≤5 printed models or tests/simulations). Finally, 22 studies were included and analyzed. Computed tomography angiography (CTA) was the primary diagnostic method used to obtain the images serving as the basis for generating the 3D-printed models. Processing the CTA data involved the use of medical imaging software; 3DSlicer (Brigham and Women’s Hospital, Harvard University, Boston, MA), ITK-Snap, and Mimics (Materialise NV, Leuven, Belgium) were the most frequently used. Autodesk Meshmixer (San Francisco, CA, USA) and 3-matic (Materialise NV, Leuven, Belgium) were the most frequently employed mesh-editing software during the post-processing phase. PolyJet™, fused deposition modeling (FDM), and stereolithography (SLA) were the most frequently employed 3D-printing technologies. Planning and training with 3D-printed models seem to enhance physicians’ confidence and performance levels by up to 40% and lead to a reduction in the procedure time and contrast volume usage to varying extents.

19 February 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Ruben ForestiRuben Foresti
Ruben Foresti
AFAnna Fornasari
Anna Fornasari
CMClaudio Bianchini Massoni
Claudio Bianchini Massoni
AMArianna Mersanne
Arianna Mersanne
Chiara MartiniChiara Martini
Chiara Martini
Paolo PeriniPaolo Perini
Paolo Perini
There is currently a shift in surgical training from traditional methods to simulation-based approaches, recognizing the necessity of more effective and controlled learning environments. This study introduces a completely new 3D-printed modular system for endovascular surgery training (M-SET), developed to allow various difficulty levels. Its design was based on computed tomography angiographies from real patient data with femoro-popliteal lesions. The study aimed to explore the integration of simulation training via a 3D model into the surgical training curriculum and its effect on their performance. Our preliminary study included 12 volunteer trainees randomized 1:1 into the standard simulation (SS) group (3 stepwise difficulty training sessions) and the random simulation (RS) group (random difficulty of the M-SET). A senior surgeon evaluated and timed the final training session. Feedback reports were assessed through the Student Satisfaction and Self-Confidence in Learning Scale. The SS group completed the training sessions in about half time (23.13 ± 9.2 min vs. 44.6 ± 12.8 min). Trainees expressed high satisfaction with the training program supported by the M-SET. Our 3D-printed modular training model meets the current need for new endovascular training approaches, offering a customizable, accessible, and effective simulation-based educational program with the aim of reducing the time required to reach a high level of practical skills.

25 December 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
AMArianna Mersanne
Arianna Mersanne
Ruben ForestiRuben Foresti
Ruben Foresti
Chiara MartiniChiara Martini
Chiara Martini
CMCristina Caffarra Malvezzi
Cristina Caffarra Malvezzi
GRGiulia Rossi
Giulia Rossi
Paolo PeriniPaolo Perini
Paolo Perini
Objectives: This study aims to develop and validate a standardized methodology for creating high-fidelity, custom-made, patient-specific 3D-printed vascular models that serve as tools for preoperative planning and training in the endovascular treatment of peripheral artery disease (PAD). Methods: Ten custom-made 3D-printed vascular models were produced using computed tomography angiography (CTA) scans of ten patients diagnosed with PAD. CTA images were analyzed using Syngo.via by a specialist to formulate a medical prescription that guided the model’s creation. The CTA data were then processed in OsiriX MD to generate the .STL file, which is further refined in a Meshmixer. Stereolithography (SLA) 3D printing technology was employed, utilizing either flexible or rigid materials. The dimensional accuracy of the models was evaluated by comparing their CT scan images with the corresponding patient data, using OsiriX MD. Additionally, both flexible and rigid models were evaluated by eight vascular surgeons during simulations in an in-house-designed setup, assessing both the technical aspects and operator perceptions of the simulation. Results: Each model took approximately 21.5 h to fabricate, costing €140 for flexible and €165 for rigid materials. Bland–Alman plots revealed a strong agreement between the 3D models and patient anatomy, with outliers ranging from 4.3% to 6.9%. Simulations showed that rigid models performed better in guidewire navigation and catheter stability, while flexible models offered improved transparency and lesion treatment. Surgeons confirmed the models’ realism and utility. Conclusions: The study highlights the cost-efficient, high-fidelity production of 3D-printed vascular models, emphasizing their potential to enhance training and planning in endovascular surgery.

2 June 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
BGBENEDETTA GHEZZI
BENEDETTA GHEZZI
Ruben ForestiRuben Foresti
Ruben Foresti
LSLuisa Pia Scialoia
Luisa Pia Scialoia
MBMaddalena Botti
Maddalena Botti
AMArianna Mersanne
Arianna Mersanne
AFAntonio Freyrie
Antonio Freyrie
Background/Objectives: Drug-coated balloons (DCBs) are emerging as a promising treatment for peripheral artery disease; however, current technologies lack flexibility in customizing drug release profiles and composition, limiting their therapeutic potential. This study aims to develop a Gelatin (Gel) and Sodium Alginate (Alg) bioink loaded with apolipoprotein A-I (apoA-I) for controlled drug delivery by using additive manufacturing technologies. Methods: We developed and printed via rapid freeze prototyping (RFP) a Gel and Alg bioink loaded with different concentrations of apoA-I. Mechanical properties related to compressional and tensile forces have been studied, as well as the structural stability and active release from the 3D structure of apoA-I (cholesterol efflux assays). The biological behavior of HUVEC cells with and without ApoA-I was assessed by proliferation assay, metabolic activity analysis, and fluorescence imaging. Results: The 3D structures presented breakpoint stress values consistent with the mechanical requirements for integration within a DCB, and the ability to effectively promote cholesterol transport in J774 cells. Moreover, in vitro studies on HUVECs revealed that the scaffolds exhibited no cytotoxic effects, leading to increased ATP levels and enhanced metabolic activity over time, confirming the possibility to obtain RFP-printed Alg/Gel scaffolds able to provide a stable structure capable of controlled apoA-I release. Conclusions: These findings support the potential of Alg/Gel+apoA-I scaffolds as biocompatible drug delivery systems for vascular applications. Their ability to maintain structural integrity while enabling controlled biomolecular release positions them as promising candidates for personalized cardiovascular therapy, facilitating the rapid customization of bioprinted therapeutic platforms.

19 June 2026 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Open access
Paolo PeriniPaolo Perini
Paolo Perini
Chiara MartiniChiara Martini
Chiara Martini
CMClaudio Bianchini Massoni
Claudio Bianchini Massoni
MPMatteo Puntoni
Matteo Puntoni
GMGiuseppe Maglietta
Giuseppe Maglietta
Ruben ForestiRuben Foresti
Ruben Foresti
This trial aimed to assess whether custom made three dimensional (3D) printed vascular models improve procedural outcomes when used for pre-operative planning and simulation in endovascular treatment (EVT) of aorto-iliac-femoropopliteal peripheral artery disease (PAD). This single centre, single blind randomised controlled trial (3DPAD-1), registered on ClinicalTrials.gov (Identifier: NCT07000097), enrolled consecutive patients scheduled for EVT between January 2022 and September 2024. Participants were randomised 1 : 1 to standard planning based on computed tomography angiography (CTA) alone (standard group, SG) or CTA plus 3D printed model based planning and simulation (3D model group, 3DMG). The prespecified coprimary endpoints were the cumulative 30 day incidence of peri-operative complications and total procedure duration. Secondary endpoints included technical success, contrast medium volume, radiation exposure, fluoroscopy time, and number of devices used. Of 166 patients screened, 106 were randomised (53 per arm); 99 underwent the allocated intervention (48 in the 3DMG, 51 in the SG). The cumulative incidence of complications was significantly lower in the 3DMG (20.8%) than in the SG (49.0%; p = .006). The univariable logistic model (OR 0.27, 95% CI 0.11 - 0.66; p = .004), the multivariable model (adjusted OR 0.22, 95% CI 0.08 - 0.60; p = .004), and the propensity weighted analyses (Average Treatment Effect OR 0.33, 95% CI 0.13 - 0.86; p = .023; Average Treatment Effect in the Overlap Population OR 0.35, 95% CI 0.14 - 0.79; p = .023) consistently confirmed the protective effect of the 3D model. Procedure duration was significantly shorter in the 3DMG (mean difference -40.3 minutes; p < .001), confirmed in adjusted and weighted models. No significant between group differences were observed in other peri-operative outcomes. Custom made 3D printed models significantly reduced peri-operative complications and procedure duration in EVT for PAD, supporting their role in improving procedural planning and efficiency. These findings support the selective adoption of 3D printed models for complex endovascular interventions to enhance procedural efficiency and patient safety.