Nenad Sarunac

Dr. Nenad Sarunac


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
AJAlireza Javanshir
Alireza Javanshir
NSNenad Sarunac
Nenad Sarunac
ZPZahra Panah
Zahra Panah
The analysis and optimization of an organic Rankine cycle (ORC) used as a bottoming cycle in the Brayton/ORC and steam Rankine/ORC combined cycle configurations is the main focus of this study. The results show that CO2 and air are the best working fluids for the topping (Brayton) cycle. Depending on the exhaust temperature of the topping cycle, Iso-butane, R11 and ethanol are the preferred working fluids for the bottoming (ORC) cycle, resulting in the highest efficiency of the combined cycle. Results of the techno-economic study show that combined Brayton/ORC cycle has significantly lower total capital investment and levelized cost of electricity (LCOE) compared to the regenerative Brayton cycle. An analysis of a combined steam Rankine/ORC cycle was performed to determine the increase in power output that would be achieved by adding a bottoming ORC to the utility-scale steam Rankine cycle, and determine the effect of ambient conditions (heat sink temperature) on power increase. For the selected power plant location, the large difference between the winter and summer temperatures has a considerable effect on the ORC power output, which varies by more than 60% from winter to summer.

16 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
ZTZecan Tu
Zecan Tu
DKDaniela Piccioni Koch
Daniela Piccioni Koch
NSNenad Sarunac
Nenad Sarunac
MFMartin Frank
Martin Frank
JMJunkui Mao
Junkui Mao
The heat transfer performance of a solar external receiver tube with guide vanes was numerically studied under non-uniform heat flux conditions. Models of the smooth tube and the tube with guide vanes were built. The distributions of the temperature, velocity, turbulence intensity, and Nu predicted by these two models were compared to investigate the heat transfer enhancement and the mixing effect of the guide vanes. The effect of the Re and the α on the heat transfer enhancement was also studied. The results show that the guide vanes form spiraling flows, reduce the maximum tube and molten salt temperatures, and improve the heat transfer. In addition, a more uniform temperature distribution is achieved compared to the smooth tube, allowing the molten salt to work safely under higher heat flux conditions in the receiver tube with guide vanes. It was observed that a larger Re enhances the heat transfer on the tube wall and achieves a longer effective distance of enhanced heat transfer in the downstream region, while the spiraling flow, the heat transfer enhancement, and the mixing are stronger for a larger α.

15 February 2024
Verified
Report
Open access
PDF file
WOWorley
Worley
NSNenad Sarunac
Nenad Sarunac
CRCarlos Romero
Carlos Romero
JKJavad Khalesi
Javad Khalesi
MKMahfuja Khuda
Mahfuja Khuda
EYEmad Yaghmour
Emad Yaghmour
The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts [3] and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerablymore » during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations. « less