abir hezzi

Ms. abir hezzi


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019
Verified
Conference Paper
Open access
AHabir hezzi
abir hezzi
YBYemna Bensalem
Yemna Bensalem
Seifeddine Ben El GhaliSeifeddine Ben El Ghali
Seifeddine Ben El Ghali
MAMohamed Naceur Abdelkrim
Mohamed Naceur Abdelkrim
The impact of the third order current harmonic cannot be ignored in a five-phase permanent magnet synchronous motor (PMSM), on the contrary of the three-phase PMSM. So, to realize the speed sensorless control for PMSM, a Sliding Mode Observer (SMO) is suggested with consideration the impact of third order harmonic. At the outset, a Sliding Mode Control (SMC) with injection of the third order current harmonic is designed for speed sensorless control of PMSM model for Electric Vehicle (EV). Then, Sliding Mode Observer is built to estimate the motor speed, torque and current in (d,q) frame, in order to improve the performance of sensorless control strategy. Besides, the stability of the SMC and SMO are studied using Lyapunov stability criteria. The feasibility of this technique will be evaluated using MATLAB/Simulink platform.

16 January 2024 in Machines
Verified
Journal Article
Open access
PDF file
AHabir hezzi
abir hezzi
Elhoussin ElbouchikhiElhoussin Elbouchikhi
Elhoussin Elbouchikhi
Allal El Moubarek BouzidAllal El Moubarek Bouzid
Allal El Moubarek Bouzid
Seifeddine Ben El GhaliSeifeddine Ben El Ghali
Seifeddine Ben El Ghali
Mohamed ZerrouguiMohamed Zerrougui
Mohamed Zerrougui
Mohamed BenbouzidMohamed Benbouzid
Mohamed Benbouzid
Motivated by the significant efforts developed by researchers and engineers to improve the economic and technical performance of microgrids (MGs), this paper proposes an Active Disturbance Rejection Control (ADRC) for Distributed Energy Resources (DER) in microgrids. This approach is a nonlinear control that is based on a real-time compensation of different estimated disturbances. The DER operates along with the electrical grid to provide the load requirements. This load has a nonlinear and uncertain character, which presents a source of unmodeled dynamics and harmonic perturbations of the MG. The main objective of this paper is to ensure the stability and the continuity of service of the distributed generation resources by controlling the DC-AC converter. The ADRC as a robust control technique is characterized by its ability to compensate for the estimated total disturbances caused by the load variation and the external unmodeled perturbations to guarantee the high tracking performance of sinusoidal reference signals in the DER system. The ADRC technique is characterized by its nonlinear function, which provides a high robustness to the controlled system. However, in order to simplify the control structure by keeping its high reliability, this paper proposes to replace the nonlinear function with a simple error (termed linear ADRC), compares the impact of this modification on the system performances, and evaluates its operation in the presence of linear and nonlinear load variations. Simulation results are presented to demonstrate the efficiency of the proposed control approach for a three-phase DER.