Ren Jing

Dr. Ren Jing


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2016 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
YLYing Liu
Ying Liu
JLJian Li
Jian Li
HZHongliang Zhao
Hongliang Zhao
YJYan Jia
Yan Jia
RJRen Jing
Ren Jing
MZMinwen Zheng
Minwen Zheng
All studies involving use of ionizing radiation should be performed in accordance with the ALARA (As Low As Reasonably Achievable) principle, especially in children. In this study, the prospective ECG triggering technique with low voltage was used in dual-source computed tomography (DSCT) angiography to investigate if image quality with low radiation dose could be satisfactory in pediatric patients with congenital heart disease. Sixty pediatric patients with suspected congenital cardiovascular anomalies were enrolled prospectively in the study. They were randomly assigned to two groups for DSCT angiography. Group A were scanned by prospective ECG-triggering computed tomography angiography (CTA) with 80 kV tube voltage, while group B by used non-ECG-gated CTA with the same tube voltage. The anomaly accuracy was evaluated based on the surgical and/or conventional cardiac angiography findings. The overall image quality was assessed on a five-point scale. And the diagnostic accuracy and radiation dose was evaluated in both groups. There were 127 cardiovascular anomalies in Group A and 108 in Group B. The mean subjective image quality and diagnostic accuracy between these two groups were significantly different (P = 0.007 and 0.011, respectively). The mean effective dose in Group A and Group B was 0.38 ± 0.13 mSv and 0.35 ± 0.17 mSv, respectively. But there was no significant difference between two groups (P = 0.197). The prospective ECG triggering technique in DSCT scan can offer better image quality and diagnostic accuracy with low radiation exposure in pediatric patients with congenital heart diseases. This technique has potential to become a new clinical routine in pediatric cardiac computed tomography (CT) imaging.

12 December 2013 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
YLYing Liu
Ying Liu
JXJian Xu
Jian Xu
JLJian Li
Jian Li
RJRen Jing
Ren Jing
HLHongtao Liu
Hongtao Liu
MZMinwen Zheng
Minwen Zheng
Background: Aortic dissection is a lift-threatening medical emergency associated with high rates of morbidity and mortality. The incidence rate of aortic dissection is estimated at 5 to 30 per 1 million people per year. The prompt and correct diagnosis of aortic dissection is critical. This study was to compare the ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography and conventional dual-source CT angiography. Methods: A total of 110 consecutive patients with suspected aortic dissection and other aortic disorders were randomly divided into two groups. Group A underwent traditional scan mode and Group B underwent high-pitch dual-source CT scan mode. The image quality and radiation dose of two groups were compared. Results: Close interobserver agreement was found for image quality scores (κ = 0.87). The image quality of ascending aorta was significantly better in the high-pitch group than in the conventional group (2.78 ± 0.46 vs 1.57 ± 0.43, P < 0.001). There was no significant difference of the CT attenuation values, the aortic image noise and SNR between two groups. The mean radiation dose of high-pitch group was also significantly lower than that of conventional group (2.7 ± 0.6 mSv vs. 3.9 ± 0.9 mSv, P < 0.001). Conclusions: High-pitch dual-source CT angiography of the whole aorta can provide motion-artifact-free imaging of the ascending aorta at a low radiation dose compared to conventional protocol.

6 August 2014 in European Radiology
Verified
Journal Article
Closed access
PDF file
RJRen Jing
Ren Jing
HLHuijia Liu
Huijia Liu
He WangHe Wang
He Wang
DWDidi Didi Wen
Didi Didi Wen
XHXufang Huang
Xufang Huang
YHYi Huan
Yi Huan

1 March 2016 in Medicine
Verified
Journal Article
Open access
JZJinman Zhong
Jinman Zhong
WZWeiwei Zhao
Weiwei Zhao
WMWanling Ma
Wanling Ma
FRFang Ren
Fang Ren
SQShun Qi
Shun Qi
YHYi Huan
Yi Huan
The purpose of the hypothesis testing is to determine that apparent diffusion coefficient (ADC) as an early biomarker can predict the metastatic lymph nodes’ (LNs) response to neoadjuvant chemotherapy in advanced gastric cancer (GC) in early stage. From March 2011 to June 2015, 106 patients with advanced GC were enrolled in the study. Patients underwent conventional magnetic resonance imaging and functional diffusion weighted imaging before and 3 days, 7 days, 30 days, and 60 days following the standard chemotherapy. After surgery, among 3034 detected LNs, the positive group was divided into complete response (CR) group, partial response (PR) group, and stable disease (SD) group in accordance to the Response Evaluation Criteria in Solid Tumors (RECIST) 1.1. Mean ADCs, short/long diameters of LNs before chemotherapy between the whole positive and the negative LNs were compared by t test. Changes of mean ADCs in 3 groups were analyzed by 1-way ANOVA. The mean ADC of the whole positive LNs was (1.145 ± 0.014) × 10−3 mm2/s, which was significantly lower than that of the whole negative LNs ([1.491 ± 0.010] × 10−3 mm2/s; P < 0.05). The means of both short/long diameters in the whole positive LNs were significantly longer than those in the whole negative LNs (P < 0.05). In CR, PR, and SD groups, the mean ADC of metastatic LNs on the 3rd day, 7th day, 13th day, and 16th day following the chemotherapy were all higher than that of LNs before chemotherapy, respectively (all P < 0.05). In addition, significant difference was found between mean ADCs in any 2 time points (all P < 0.05), except between mean ADCs in the 3rd day and in the 7th day of the chemotherapy. In conclusion, ADC can be used as an early biomarker to predict the metastatic LNs’ response to neoadjuvant chemotherapy in advanced GC in early stage.

19 August 2021 in Chinese Journal of Academic Radiology
Verified
Journal Article
Open access
PDF file
RWRui Wang
Rui Wang
WLWeidong Liu
Weidong Liu
FRFang Ren
Fang Ren
RJRen Jing
Ren Jing
Objective To quantitatively compare the diagnostic and differential diagnostic value of intra-voxel incoherent motion imaging (IVIM) and diffusion weighted imaging (DWI) for prostate cancer (PCa) and benign prostatic hyperplasia (BPH). Methods 68 cases of prostate confirmed by pathology, including 33 cases of PCa and 35 cases of BPH were analyzed retrospectively. All patients were underwent T1WI, T2WI, DWI and IVIM sequences to obtain the apparent diffusion coefficient (ADC), pure apparent diffusion coefficient (Pure-ADC/D), standard apparent diffusion coefficient (standard-ADC/Ds), fast apparent diffusion coefficient (fast-ADC/D*), fraction of fast apparent diffusion coefficient (f) values. All the multiple parameters were statistically analyzed for the differential diagnosis of BPH and PCa. P < 0.05 was considered as statistically significant. Results The differences in D, Ds, f and ADC values between BPH and PCa groups were statistically significant (all P values < 0.001), respectively. Among them, D value in the IVIM model had the highest diagnostic efficiency for PCa, the area under the curve (AUC) was 0.967, and the AUC combined with the ADC value and D value reaches 0.973. Conclusion The diagnostic efficacy of multiple parameters in the IVIM model for PCa was higher than the ADC value of the quantitative parameter of DWI. D value had the highest diagnostic efficiency. The combined diagnosis of ADC and D value was more effective, more advantageous in the diagnosis and differential diagnosis of PCa.

8 December 2024 in Anatomical Sciences Education
Verified
Journal Article
Closed access
LMLi‐Na Ma
Li‐Na Ma
RPRui Peng
Rui Peng
JXJing‐Ji Xu
Jing‐Ji Xu
QYQing‐Ling Yang
Qing‐Ling Yang
ALA‐Ceng Li
A‐Ceng Li
RJRen Jing
Ren Jing