Jose Alonso Solis-Lemus

Dr. Jose Alonso Solis-Lemus

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
CRCaroline H. Roney
Caroline H. Roney
ISIain Sim
Iain Sim
JYJin Yu
Jin Yu
MBMarianne Beach
Marianne Beach
AMArihant Mehta
Arihant Mehta
SNSteven A. Niederer
Steven A. Niederer
Background: Current ablation therapy for atrial fibrillation is suboptimal, and long-term response is challenging to predict. Clinical trials identify bedside properties that provide only modest prediction of long-term response in populations, while patient-specific models in small cohorts primarily explain acute response to ablation. We aimed to predict long-term atrial fibrillation recurrence after ablation in large cohorts, by using machine learning to complement biophysical simulations by encoding more interindividual variability. Methods: Patient-specific models were constructed for 100 atrial fibrillation patients (43 paroxysmal, 41 persistent, and 16 long-standing persistent), undergoing first ablation. Patients were followed for 1 year using ambulatory ECG monitoring. Each patient-specific biophysical model combined differing fibrosis patterns, fiber orientation maps, electrical properties, and ablation patterns to capture uncertainty in atrial properties and to test the ability of the tissue to sustain fibrillation. These simulation stress tests of different model variants were postprocessed to calculate atrial fibrillation simulation metrics. Machine learning classifiers were trained to predict atrial fibrillation recurrence using features from the patient history, imaging, and atrial fibrillation simulation metrics. Results: We performed 1100 atrial fibrillation ablation simulations across 100 patient-specific models. Models based on simulation stress tests alone showed a maximum accuracy of 0.63 for predicting long-term fibrillation recurrence. Classifiers trained to history, imaging, and simulation stress tests (average 10-fold cross-validation area under the curve, 0.85±0.09; recall, 0.80±0.13; precision, 0.74±0.13) outperformed those trained to history and imaging (area under the curve, 0.66±0.17) or history alone (area under the curve, 0.61±0.14). Conclusion: A novel computational pipeline accurately predicted long-term atrial fibrillation recurrence in individual patients by combining outcome data with patient-specific acute simulation response. This technique could help to personalize selection for atrial fibrillation ablation.

16 May 2023 in Computers in Biology and Medicine
Verified
Journal Article
Open access
JSJose Alonso Solis-Lemus
Jose Alonso Solis-Lemus
TBTiffany Baptiste
Tiffany Baptiste
RBRosie Barrows
Rosie Barrows
CSCharles Sillett
Charles Sillett
AGAli Gharaviri
Ali Gharaviri
SNSteven Niederer
Steven Niederer
This work presents an open-source software pipeline to create patient-specific left atrial models with fibre orientations and a fibrDEFAULTosis map, suitable for electrophysiology simulations, and quantifies the intra and inter observer reproducibility of the model creation. The semi-automatic pipeline takes as input a contrast enhanced magnetic resonance angiogram, and a late gadolinium enhanced (LGE) contrast magnetic resonance (CMR). Five operators were allocated 20 cases each from a set of 50 CMR datasets to create a total of 100 models to evaluate inter and intra-operator variability. Each output model consisted of: (1) a labelled surface mesh open at the pulmonary veins and mitral valve, (2) fibre orientations mapped from a diffusion tensor MRI (DTMRI) human atlas, (3) fibrosis map extracted from the LGE-CMR scan, and (4) simulation of local activation time (LAT) and phase singularity (PS) mapping. Reproducibility in our pipeline was evaluated by comparing agreement in shape of the output meshes, fibrosis distribution in the left atrial body, and fibre orientations. Reproducibility in simulations outputs was evaluated in the LAT maps by comparing the total activation times, and the mean conduction velocity (CV). PS maps were compared with the structural similarity index measure (SSIM). The users processed in total 60 cases for inter and 40 cases for intra-operator variability. Our workflow allows a single model to be created in 16.72 ± 12.25 min. Similarity was measured with shape, percentage of fibres oriented in the same direction, and intra-class correlation coefficient (ICC) for the fibrosis calculation. Shape differed noticeably only with users' selection of the mitral valve and the length of the pulmonary veins from the ostia to the distal end; fibrosis agreement was high, with ICC of 0.909 (inter) and 0.999 (intra); fibre orientation agreement was high with 60.63% (inter) and 71.77% (intra). The LAT showed good agreement, where the median ± IQR of the absolute difference of the total activation times was 2.02 ± 2.45 ms for inter, and 1.37 ± 2.45 ms for intra. Also, the average ± sd of the mean CV difference was -0.00404 ± 0.0155 m/s for inter, and 0.0021 ± 0.0115 m/s for intra. Finally, the PS maps showed a moderately good agreement in SSIM for inter and intra, where the mean ± sd SSIM for inter and intra were 0.648 ± 0.21 and 0.608 ± 0.15, respectively. Although we found notable differences in the models, as a consequence of user input, our tests show that the uncertainty caused by both inter and intra-operator variability is comparable with uncertainty due to estimated fibres, and image resolution accuracy of segmentation tools.

15 December 2023 in Interface Focus
Verified
Journal Article
Open access
CRCaroline H. Roney
Caroline H. Roney
JSJose Alonso Solis-Lemus
Jose Alonso Solis-Lemus
CBCarlos Lopez Barrera
Carlos Lopez Barrera
AZAlexander Zolotarev
Alexander Zolotarev
OUOnur Ulgen
Onur Ulgen
SNSteven Niederer
Steven Niederer
To enable large in silico trials and personalized model predictions on clinical timescales, it is imperative that models can be constructed quickly and reproducibly. First, we aimed to overcome the challenges of constructing cardiac models at scale through developing a robust, open-source pipeline for bilayer and volumetric atrial models. Second, we aimed to investigate the effects of fibres, fibrosis and model representation on fibrillatory dynamics. To construct bilayer and volumetric models, we extended our previously developed coordinate system to incorporate transmurality, atrial regions and fibres (rule-based or data driven diffusion tensor magnetic resonance imaging (MRI)). We created a cohort of 1000 biatrial bilayer and volumetric models derived from computed tomography (CT) data, as well as models from MRI, and electroanatomical mapping. Fibrillatory dynamics diverged between bilayer and volumetric simulations across the CT cohort (correlation coefficient for phase singularity maps: left atrial (LA) 0.27 ± 0.19, right atrial (RA) 0.41 ± 0.14). Adding fibrotic remodelling stabilized re-entries and reduced the impact of model type (LA: 0.52 ± 0.20, RA: 0.36 ± 0.18). The choice of fibre field has a small effect on paced activation data (less than 12 ms), but a larger effect on fibrillatory dynamics. Overall, we developed an open-source user-friendly pipeline for generating atrial models from imaging or electroanatomical mapping data enabling in silico clinical trials at scale ( https://github.com/pcmlab/atrialmtk ).

24 August 2020 in Royal Society Open Science
Verified
Journal Article
Open access
JSJose Alonso Solis-Lemus
Jose Alonso Solis-Lemus
ECEdward Costar
Edward Costar
DDDenis Doorly
Denis Doorly
EKEric C. Kerrigan
Eric C. Kerrigan
CKCaroline H. Kennedy
Caroline H. Kennedy
SWSteven Williams
Steven Williams
The potential for acute shortages of ventilators at the peak of the COVID-19 pandemic has raised the possibility of needing to support two patients from a single ventilator. To provide a system for understanding and prototyping designs, we have developed a mathematical model of two patients supported by a mechanical ventilator. We propose a standard set-up where we simulate the introduction of T-splitters to supply air to two patients and a modified set-up where we introduce a variable resistance in each inhalation pathway and one-way valves in each exhalation pathway. Using the standard set-up, we demonstrate that ventilating two patients with mismatched lung compliances from a single ventilator will lead to clinically significant reductions in tidal volume in the patient with the lowest respiratory compliance. Using the modified set-up, we demonstrate that it could be possible to achieve the same tidal volumes in two patients with mismatched lung compliances, and we show that the tidal volume of one patient can be manipulated independently of the other. The results indicate that, with appropriate modifications, two patients could be supported from a single ventilator with independent control of tidal volumes.

21 December 2017 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
JSJose Alonso Solis-Lemus
Jose Alonso Solis-Lemus
BSBrian Stramer
Brian Stramer
GSGreg Slabaugh
Greg Slabaugh
Constantino Carlos Reyes-AldasoroConstantino Carlos Reyes-Aldasoro
Constantino Carlos Reyes-Aldasoro
Cell migration is crucial in many processes of development and maintenance of multicellular organisms and it can also be related to disease, e.g., Cancer metastasis, when cells migrate to organs different to where they originate. A precise analysis of the cell shapes in biological studies could lead to insights about migration. However, in some cases, the interaction and overlap of cells can complicate the detection and interpretation of their shapes. This paper describes an algorithm to segment and analyse the shape of macrophages in fluorescent microscopy image sequences, and compares the segmentation of overlapping cells through different algorithms. A novel 2D matrix with multiscale angle variation, called the anglegram, based on the angles between points of the boundary of an object, is used for this purpose. The anglegram is used to find junctions of cells and applied in two different applications: (i) segmentation of overlapping cells and for non-overlapping cells; (ii) detection of the “corners” or pointy edges in the shapes. The functionalities of the anglegram were tested and validated with synthetic data and on fluorescently labelled macrophages observed on embryos of Drosophila melanogaster. The information that can be extracted from the anglegram shows a good promise for shape determination and analysis, whether this involves overlapping or non-overlapping objects.

24 March 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
LHLuuk H.G.A. Hopman
Luuk H.G.A. Hopman
IFIrene M Frenaij
Irene M Frenaij
JSJose Alonso Solis-Lemus
Jose Alonso Solis-Lemus
SMSulayman el Mathari
Sulayman el Mathari
SNSteven A Niederer
Steven A Niederer
MGMarco J W Götte
Marco J W Götte
Atrial fibrosis is considered to be a key driver to the initiation and perpetuation of atrial fibrillation (AF). Histological studies evaluating human atrial fibrosis are largely restricted to tissue samples that can be collected during cardiac surgery such as atrial appendage tissue.1,2 Consequently, left atrial (LA) appendage (LAA) tissue is often used as a surrogate marker for the entire LA to assess processes of structural remodelling related to AF. Animal studies suggest that LAA tissue may act as a decent representation of the LA as the cellular composition of murine LAA and LA-body tissue was found to be rather similar.3 To the best of our knowledge however, it remains unclear whether the fibrosis content assessed in human appendage samples accurately represents the fibrosis content of the entire LA.