Rosie K. Barrows

Rosie K. Barrows

Auto-generated profile, based on publicly available information

Rosie K. Barrows

Affiliation National Heart and Lung Institute, Imperial College London, London, United Kingdom

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2023 in Computers in Biology and Medicine
Verified
Journal Article
Open access
JSJose Alonso Solis-Lemus
Jose Alonso Solis-Lemus
TBTiffany Baptiste
Tiffany Baptiste
RBRosie Barrows
Rosie Barrows
CSCharles Sillett
Charles Sillett
AGAli Gharaviri
Ali Gharaviri
SNSteven Niederer
Steven Niederer
This work presents an open-source software pipeline to create patient-specific left atrial models with fibre orientations and a fibrDEFAULTosis map, suitable for electrophysiology simulations, and quantifies the intra and inter observer reproducibility of the model creation. The semi-automatic pipeline takes as input a contrast enhanced magnetic resonance angiogram, and a late gadolinium enhanced (LGE) contrast magnetic resonance (CMR). Five operators were allocated 20 cases each from a set of 50 CMR datasets to create a total of 100 models to evaluate inter and intra-operator variability. Each output model consisted of: (1) a labelled surface mesh open at the pulmonary veins and mitral valve, (2) fibre orientations mapped from a diffusion tensor MRI (DTMRI) human atlas, (3) fibrosis map extracted from the LGE-CMR scan, and (4) simulation of local activation time (LAT) and phase singularity (PS) mapping. Reproducibility in our pipeline was evaluated by comparing agreement in shape of the output meshes, fibrosis distribution in the left atrial body, and fibre orientations. Reproducibility in simulations outputs was evaluated in the LAT maps by comparing the total activation times, and the mean conduction velocity (CV). PS maps were compared with the structural similarity index measure (SSIM). The users processed in total 60 cases for inter and 40 cases for intra-operator variability. Our workflow allows a single model to be created in 16.72 ± 12.25 min. Similarity was measured with shape, percentage of fibres oriented in the same direction, and intra-class correlation coefficient (ICC) for the fibrosis calculation. Shape differed noticeably only with users' selection of the mitral valve and the length of the pulmonary veins from the ostia to the distal end; fibrosis agreement was high, with ICC of 0.909 (inter) and 0.999 (intra); fibre orientation agreement was high with 60.63% (inter) and 71.77% (intra). The LAT showed good agreement, where the median ± IQR of the absolute difference of the total activation times was 2.02 ± 2.45 ms for inter, and 1.37 ± 2.45 ms for intra. Also, the average ± sd of the mean CV difference was -0.00404 ± 0.0155 m/s for inter, and 0.0021 ± 0.0115 m/s for intra. Finally, the PS maps showed a moderately good agreement in SSIM for inter and intra, where the mean ± sd SSIM for inter and intra were 0.648 ± 0.21 and 0.608 ± 0.15, respectively. Although we found notable differences in the models, as a consequence of user input, our tests show that the uncertainty caused by both inter and intra-operator variability is comparable with uncertainty due to estimated fibres, and image resolution accuracy of segmentation tools.

9 May 2025 in Heart Rhythm O2
Verified
Journal Article
Open access
RBRosie K. Barrows
Rosie K. Barrows
CAChristoph M. Augustin
Christoph M. Augustin
MGMatthias A.F. Gsell
Matthias A.F. Gsell
CRCaroline H. Roney
Caroline H. Roney
JLJosé A. Solís Lemus
José A. Solís Lemus
SNSteven A. Niederer
Steven A. Niederer
Atrial fibrillation (AF) alters heart rate, rhythm regularity, and atrial contraction, which may contribute to an increased risk of heart failure. Although rate and rhythm control target different aspects of these disturbances, their specific effects on left ventricular (LV) function remain unclear. The purpose of this study was to predict the independent and combined contribution of heart rate, rhythm regularity, and atrial contraction to LV function in patients with AF. We predicted LV ejection fraction (EF) and stroke volume (SV) in 10 whole-heart patient-specific models of patients with AF while varying heart rate, rhythm regularity, and effectiveness of atrial contraction. AF was modeled as a fast, irregular heart rate with no atrial contraction. Pharmacologic and paced rate control were modeled as a slow irregular and regular heart rate without atrial contraction, respectively, whereas rhythm control had a slow, regular heart rate with atrial contraction. Rhythm control resulted in a greater improvement than pharmacological rate control in LVEF compared with AF (+5.1% ± 0.4% vs +2.8% ± 0.3%, P < .01). Paced rate control was equivalent to pharmacologic rate control in terms of LVEF (+2.6% ± 0.4% vs +2.8% ± 0.3%). Atrial contraction did not improve ventricular function in the presence of an irregular heart rate (pharmacologic rate: +2.8% ± 0.3% vs rhythm with irregular heart rate: +2.7% ± 0.3%). Rhythm control provides superior improvements in LV function compared with rate control. However, restoring sinus rhythm may yield limited benefits to LV function when atrial contraction is ineffective or when heart rate is irregular.

2 June 2026 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
JSJose Alonso Solis-Lemus
Jose Alonso Solis-Lemus
RBRosie K. Barrows
Rosie K. Barrows
CRCristobal Rodero
Cristobal Rodero
MSMarina Strocchi
Marina Strocchi
NMNatalie Montarello
Natalie Montarello
SNSteven A. Niederer
Steven A. Niederer
This work presents a study on how differences in cardiac anatomy attributed to sex and disease can influence cardiac electrophysiology and mechanics using a virtual cohort of four-chamber heart models. Patient anatomy varies across sex and disease. However, capturing this variation in in-silico studies remains poorly accounted for, with studies often using either single representative cases or imbalanced virtual cohorts. Whole-heart electromechanics models incorporate the patient’s anatomy, electrophysiology and mechanics across different scales, from molecular, tissue and whole-heart and circulatory system levels. However, cardiac models are typically built from one or a small number of anatomies, with sex rarely reported and the effects of anatomical variability, which include those due to sex or disease, largely unexplored. This limits clinical translation and reduces regulatory credibility. We developed fifty patient-specific anatomical models of 25 male and 25 female hearts in heart failure and control cases. We ran benchmark passive inflation and paced activation simulations with consistent parameters and boundary conditions across cases to isolate the impact of anatomical variations with sex and disease. Heart failure models exhibited increased chamber volumes, larger volume changes during inflation, and delayed activation times relative to controls. These trends were consistent across sexes, although right ventricular activation showed a significant sex-based difference. Variations in anatomy with sex and disease have a significant impact on cardiac simulations, which support the inclusion of multiple heart anatomical models in in-silico trials. The resulting virtual cohort captures key anatomical variability and is publicly available, along with the underlying code (see Data Availability statement).