Alessandro Ramalli

Dr. Alessandro Ramalli

Department of Information Engineering, University of Florence, Florence, Tuscany, Italy
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Enrico BoniEnrico Boni
Enrico Boni
LBLuca Bassi
Luca Bassi
ADAlessandro Dallai
Alessandro Dallai
FGFrancesco Guidi
Francesco Guidi
VMValentino Meacci
Valentino Meacci
Piero TortoliPiero Tortoli
Piero Tortoli
Open scanners offer an increasing support to the ultrasound researchers who are involved in the experimental test of novel methods. Each system presents specific performance in terms of number of channels, flexibility, processing power, data storage capability, and overall dimensions. This paper reports the design criteria and hardware/software implementation details of a new 256-channel ultrasound advanced open platform. This system is organized in a modular architecture, including multiple front-end boards, interconnected by a high-speed (80 Gb/s) ring, capable of finely controlling all transmit (TX) and receive (RX) signals. High flexibility and processing power (equivalent to 2500 GFLOP) are guaranteed by the possibility of individually programming multiple digital signal processors and field programmable gate arrays. Eighty GB of on-board memory are available for the storage of prebeamforming, postbeamforming, and baseband data. The use of latest generation devices allowed to integrate all needed electronics in a small size (34 cm×30 cm×26 cm). The system implements a multiline beamformer that allows obtaining images of 96 lines by 2048 depths at a frame rate of 720 Hz (expandable to 3000 Hz). The multiline beamforming capability is also exploited to implement a real-time vector Doppler scheme in which a single TX and two independent RX apertures are simultaneously used to maintain the analysis over a full pulse repetition frequency range.

13 August 2015 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Enrico BoniEnrico Boni
Enrico Boni
Alessandro Stuart SavoiaAlessandro Stuart Savoia
Alessandro Stuart Savoia
Piero TortoliPiero Tortoli
Piero Tortoli
The current high interest in 3-D ultrasound imaging is pushing the development of 2-D probes with a challenging number of active elements. The most popular approach to limit this number is the sparse array technique, which designs the array layout by means of complex optimization algorithms. These algorithms are typically constrained by a few steering conditions, and, as such, cannot guarantee uniform side-lobe performance at all angles. The performance may be improved by the ungridded extensions of the sparse array technique, but this result is achieved at the expense of a further complication of the optimization process. In this paper, a method to design the layout of large circular arrays with a limited number of elements according to Fermat's spiral seeds and spatial density modulation is proposed and shown to be suitable for application to 3-D ultrasound imaging. This deterministic, aperiodic, and balanced positioning procedure attempts to guarantee uniform performance over a wide range of steering angles. The capabilities of the method are demonstrated by simulating and comparing the performance of spiral and dense arrays. A good trade-off for small vessel imaging is found, e.g., in the 60λ spiral array with 1.0λ elements and Blackman density tapering window. Here, the grating lobe level is -16 dB, the lateral resolution is lower than 6λ the depth of field is 120λ and, the average contrast is 10.3 dB, while the sensitivity remains in a 5 dB range for a wide selection of steering angles. The simulation results may represent a reference guide to the design of spiral sparse array probes for different application fields.

25 September 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
SHSevan Harput
Sevan Harput
KCKirsten Christensen-Jeffries
Kirsten Christensen-Jeffries
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
JBJemma Brown
Jemma Brown
JZJiaqi Zhu
Jiaqi Zhu
MTMeng-Xing Tang
Meng-Xing Tang
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout. High-frame-rate volumetric imaging was performed using two synchronized ULA-OP 256 research scanners. Volumetric images were constructed by coherently compounding nine-angle plane waves acquired at a pulse repetition frequency of 4500 Hz. Localization-based 3-D super-resolution images of two touching subwavelength tubes were generated from 6000 volumes acquired in 12 s. Finally, this work demonstrates the feasibility of 3-D super-resolution imaging and super-resolved velocity mapping using a customized 2-D sparse array transducer.

23 January 2014 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
LTLing Tong
Ling Tong
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
RJRuta Jasaityte
Ruta Jasaityte
Piero TortoliPiero Tortoli
Piero Tortoli
JDJan D'hooge
Jan D'hooge
High frame rate (HFR) echocardiography may be of benefit for functional analysis of the heart. In current clinical equipment, HFR is obtained using multi-line acquisition (MLA) which typically requires broadening of transmit beams. As this may result in a significant degradation of spatial resolution and signal-to-noise ratio (SNR), the capacity of MLA to obtain high quality HFR images remains limited. As an alternative, we have demonstrated by computer simulation that simultaneously transmitting multiple focused beams into different directions [multi-line transmit (MLT)], can increase the frame rate without significantly compromising the spatial resolution or SNR. This study aimed to experimentally verify these theoretical predictions both in vitro and in vivo to demonstrate, for the first time, that cardiac MLT imaging is feasible. Hereto, the ultrasound advanced open platform, equipped with a 2.0 MHz phased array, was programmed to interleave MLT and conventional single line transmit (SLT) beam forming. Using these two beam forming methods, images of phantoms and healthy volunteers were acquired and investigated both qualitatively and quantitatively. The results confirmed our simulations that image quality of a 4MLT imaging system with a Tukey apodization scheme is very competitive to that of SLT while providing a 4 times higher frame rate. It is also demonstrated that MLT can be combined with MLA to provide images at 12-to 16-fold frame rate (about 340-450 Hz) without significantly compromising spatial resolution and SNR. This is thus the first study to demonstrate that this new ultrasound imaging paradigm is viable which could have significant impact on future cardiac ultrasound systems.

18 July 2012 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Enrico BoniEnrico Boni
Enrico Boni
LBLuca Bassi
Luca Bassi
ADAlessandro Dallai
Alessandro Dallai
FGFrancesco Guidi
Francesco Guidi
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Piero TortoliPiero Tortoli
Piero Tortoli
The availability of programmable and reconfigurable ultrasound (US) research platforms may have a considerable impact on the advancement of ultrasound systems technology; indeed, they allow novel transmission strategies or challenging processing methods to be tested and experimentally refined. In this paper, the ULtrasound Advanced Open Platform (ULA-OP), recently developed in our University laboratory, is shown to be a flexible tool that can be easily adapted to a wide range of applications. Five nonstandard working modalities are illustrated. Vector Doppler and quasi-static elastography applications emphasize the real-time potential and versatility of the system. Flow-mediated dilation, pulse compression, and high-frame-rate imaging highlight the flexibility of data access at different points in the reception chain. For each modality, the role played by the onboard programmable devices is discussed. Experimental results are reported, indicating the relative performance of the system for each application.

25 March 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Enrico BoniEnrico Boni
Enrico Boni
EREmmanuel Roux
Emmanuel Roux
HLHerve Liebgott
Herve Liebgott
Piero TortoliPiero Tortoli
Piero Tortoli
An ultrasound sparse array consists of a sparse distribution of elements over a 2-D aperture. Such an array is typically characterized by a limited number of elements, which in most cases is compatible with the channel number of the available scanners. Sparse arrays represent an attractive alternative to full 2-D arrays that may require the control of thousands of elements through expensive application-specific integrated circuits (ASICs). However, their massive use is hindered by two main drawbacks: the possible beam profile deterioration, which may worsen the image contrast, and the limited signal-to-noise ratio (SNR), which may result too low for some applications. This article reviews the work done for three decades on 2-D ultrasound sparse arrays for medical applications. First, random, optimized, and deterministic design methods are reviewed together with their main influencing factors. Then, experimental 2-D sparse array implementations based on piezoelectric and capacitive micromachined ultrasonic transducer (CMUT) technologies are presented. Sample applications to 3-D (Doppler) imaging, super-resolution imaging, photo-acoustic imaging, and therapy are reported. The final sections discuss the main shortcomings associated with the use of sparse arrays, the related countermeasures, and the next steps envisaged in the development of innovative arrays.