The structure of microvasculature cannot be resolved using standard clinical ultrasound (US) imaging frequencies due to the fundamental diffraction limit of US waves. In this work, we use a standard clinical US system to perform in vivo sub-diffraction imaging on a CD1, female mouse aged eight weeks by localizing isolated US signals from microbubbles flowing within the ear microvasculature, and compare our results to optical microscopy. Furthermore, we develop a new technique to map blood velocity at super-resolution by tracking individual bubbles through the vasculature. Resolution is improved from a measured lateral and axial resolution of 112 μm and 94 μm respectively in original US data, to super-resolved images of microvasculature where vessel features as fine as 19 μm are clearly visualized. Velocity maps clearly distinguish opposing flow direction and separated speed distributions in adjacent vessels, thereby enabling further differentiation between vessels otherwise not spatially separated in the image. This technique overcomes the diffraction limit to provide a noninvasive means of imaging the microvasculature at super-resolution, to depths of many centimeters. In the future, this method could noninvasively image pathological or therapeutic changes in the microvasculature at centimeter depths in vivo.
Ultrasound (US) is a widely used clinical imaging modality that offers penetration depths in tissue of >10 cm. However, the spatial resolution in US imaging is fundamentally limited by diffraction to approximately half the wavelength of the sound wave employed. The spatial resolution of optical microscopy is limited by the same fundamental physics, but in recent years super-resolution imaging techniques have been developed that overcome the diffraction limit through the localization of many spatially separated photo-switchable or photo-activatable fluorophores. In this paper, we apply a related approach to demonstrate super-resolution imaging with US. We imaged dilute suspensions of microbubble contrast agents flowing through narrow tube-based phantoms. By spatially localizing multiple spatially isolated microbubbles, we constructed super-resolved microbubble location density maps that clearly resolve features 5.1-2.2 times smaller than the US system point spread function full width half maximum in the lateral and axial directions respectively. Our initial characterization experiment using a fixed 100 µm diameter brass wire and a US frequency of 2 MHz suggests that for an ideal stationary point scatterer the ultimate resolution of the unmodified clinical US system used could be in the range of 2-4 µm.
9 April 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
The structure of microvasculature cannot be resolved using conventional ultrasound (US) imaging due to the fundamental diffraction limit at clinical US frequencies. It is possible to overcome this resolution limitation by localizing individual microbubbles through multiple frames and forming a superresolved image, which usually requires seconds to minutes of acquisition. Over this time interval, motion is inevitable and tissue movement is typically a combination of large- and small-scale tissue translation and deformation. Therefore, super-resolution (SR) imaging is prone to motion artifacts as other imaging modalities based on multiple acquisitions are. This paper investigates the feasibility of a two-stage motion estimation method, which is a combination of affine and nonrigid estimation, for SR US imaging. First, the motion correction accuracy of the proposed method is evaluated using simulations with increasing complexity of motion. A mean absolute error of 12.2 $\mu \text{m}$ was achieved in simulations for the worst-case scenario. The motion correction algorithm was then applied to a clinical data set to demonstrate its potential to enable in vivo SR US imaging in the presence of patient motion. The size of the identified microvessels from the clinical SR images was measured to assess the feasibility of the two-stage motion correction method, which reduced the width of the motion-blurred microvessels to approximately 1.5-fold.
By using microbubbles, three-dimensional super-resolution US in vivo imaging of rabbit lymph nodes visualizes the complex microvascular network and blood flow dynamics with a resolution well beyond the wave diffraction limit, giving the ability to resolve microvessels 30 µm apart. Background Variations in lymph node (LN) microcirculation can be indicative of metastasis. The identification and quantification of metastatic LNs remains essential for prognosis and treatment planning, but a reliable noninvasive imaging technique is lacking. Three-dimensional super-resolution (SR) US has shown potential to noninvasively visualize microvascular networks in vivo. Purpose To study the feasibility of three-dimensional SR US imaging of rabbit LN microvascular structure and blood flow by using microbubbles. Materials and Methods In vivo studies were carried out to image popliteal LNs of two healthy male New Zealand white rabbits aged 6–8 weeks. Three-dimensional, high-frame-rate, contrast material–enhanced US was achieved by mechanically scanning with a linear imaging probe. Individual microbubbles were identified, localized, and tracked to form three-dimensional SR images and super-resolved velocity maps. Acoustic subaperture processing was used to improve image contrast and to generate enhan...
25 September 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
High-frame-rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction-limited resolution in every spatial direction. However, 3-D super-resolution ultrasound imaging using a full 2-D array requires a system with a large number of independent channels, the design of which might be impractical due to the high cost, complexity, and volume of data produced. In this study, a 2-D sparse array was designed and fabricated with 512 elements chosen from a density-tapered 2-D spiral layout. High-frame-rate volumetric imaging was performed using two synchronized ULA-OP 256 research scanners. Volumetric images were constructed by coherently compounding nine-angle plane waves acquired at a pulse repetition frequency of 4500 Hz. Localization-based 3-D super-resolution images of two touching subwavelength tubes were generated from 6000 volumes acquired in 12 s. Finally, this work demonstrates the feasibility of 3-D super-resolution imaging and super-resolved velocity mapping using a customized 2-D sparse array transducer.