Björn Schiricke

Dr. Björn Schiricke

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2009 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
BSBjörn Schiricke
Björn Schiricke
RPRobert Zentrum für Luft- und Raumfahrt e.V. Pitz-Paal
Robert Zentrum für Luft- und Raumfahrt e.V. Pitz-Paal
ELEckhard Lüpfert
Eckhard Lüpfert
KPKlaus Pottler
Klaus Pottler
MPMarkus Pfänder
Markus Pfänder
ANAndreas Neumann
Andreas Neumann
In order to optimize the solar field output of parabolic trough collectors (PTCs), it is essential to study the influence of collector and absorber geometry on the optical performance. The optical ray-tracing model of PTC conceived for this purpose uses photogrammetrically measured concentrator geometry in commercial Monte Carlo ray-tracing software. The model has been verified with measurements of a scanning flux measurement system, measuring the solar flux density distribution close to the focal line of the PTC. The tool uses fiber optics and a charged coupled device camera to scan the focal area of a PTC module. Since it is able to quantitatively detect spilled light with good spatial resolution, it provides an evaluation of the optical efficiency of the PTC. For comparison of ray-tracing predictions with measurements, both flux maps and collector geometry have been measured under identical conditions on the Eurotrough prototype collector at the Plataforma Solar de Almería. The verification of the model is provided by three methods: the comparison of measured intercept factors with corresponding simulations, comparison of measured flux density distributions with corresponding ray-tracing predictions, and comparison of thermographically measured temperature distribution on the absorber surface with flux density distribution predicted for this surface. Examples of sensitivity studies performed with the validated model are shown.

24 November 2023 in Sustainable Cities and Society
Verified
Journal Article
Open access
LBLuis Blanco
Luis Blanco
AAAlaa Alhamwi
Alaa Alhamwi
BSBjörn Schiricke
Björn Schiricke
BHBernhard Hoffschmidt
Bernhard Hoffschmidt

15 July 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LWLukas Anselm Wille
Lukas Anselm Wille
BSBjörn Schiricke
Björn Schiricke
KGKai Gehrke
Kai Gehrke
BHBernhard Hoffschmidt
Bernhard Hoffschmidt
We study the potential of infrared (IR) heaters in combination with IR reflective walls to reduce heating energy demand in buildings. Using IR heaters increases radiant temperature. Combined with IR reflective walls, less radiant heat is absorbed by the surrounding walls, and more is reflected to and absorbed by the occupants. This allows for lower air temperatures while maintaining constant thermal comfort. Lower air temperatures result in heating energy savings. In simulations, we examine the impact of four parameters on the thermal comfort indicator Predicted Mean Vote (PMV): wall temperature, inlet air temperature, IR heater power, and IR emissivity of the walls. To reduce the number of data points needed, we use a Central Composite Design for the layout of the simulation plan. The results show that the PMV can be changed from 0.15 to 1.16 only by lowering the emissivity of the surrounding walls from 0.9 to 0.1. At high IR heater power and at low wall temperature the impact of the emissivity on the PMV becomes larger. From the simulation data, we derive a response surface function to determine the required IR heating power for any given room conditions, which could be used for automated IR heater control.

19 April 2024 in Buildings
Verified
Journal Article
Open access
PDF file
BSBjörn Schiricke
Björn Schiricke
MDMarkus Diel
Markus Diel
BKBenedikt Kölsch
Benedikt Kölsch
Maintaining the airtightness of building envelopes is critical to the energy efficiency of buildings, yet leak detection remains a significant challenge, particularly during building refurbishment. This study addresses the effectiveness of the acoustic beamforming measurement method in identifying leaks in building envelopes. For this reason, an in-field study employing the acoustic beamforming measurement method was conducted. The study involved testing over 30 rooms across three different multi-story office buildings of varying ages and heterogeneous envelope structures. Numerous leaks were located in the façades, which were subsequently visually confirmed or even verified with smoke sticks. The data, captured using an acoustic camera (a microphone ring array), revealed distinct spectra that indicate the method’s potential for further research. The basic functionality and the significant potential of this methodology for localizing leakages in large buildings were proven.

1 October 2019
Verified
Book Chapter
Closed access
BKBenedikt Kölsch
Benedikt Kölsch
ATArne Tiddens
Arne Tiddens
JSJacob Estevam Schmiedt
Jacob Estevam Schmiedt
BSBjörn Schiricke
Björn Schiricke
BHBernhard Hoffschmidt
Bernhard Hoffschmidt

31 August 2021 in International Journal of Ventilation
Verified
Journal Article
Closed access
BKBenedikt Kölsch
Benedikt Kölsch
IWIain Walker
Iain Walker
BSBjörn Schiricke
Björn Schiricke
WDWilliam W. Delp
William W. Delp
BHBernhard Hoffschmidt
Bernhard Hoffschmidt
Today, the fan pressurization method is the most frequently used method to evaluate a building's airtightness. However, the localization and quantification of leaks remain difficult. In this paper, an acoustic method is introduced to estimate the leakage size of single leaks. Acoustic and airflow measurements were conducted and compared in laboratory tests within the same boundary conditions. This work aims to investigate if various leak sizes can be predicted using acoustic measurement methods. The test apparatus consists of two chambers, separated by a test wall. This wall represents a single characteristic air leakage path. Various types of wall structures with different slit geometries, wall thicknesses, and insulation materials were investigated. The acoustic measurements were performed with a sound source placed in one chamber and ultrasonic microphones located in both chambers. These results were compared to measured airflows through the test wall to provide estimates of uncertainty in the acoustic approach, which indicate a linear trend. Finally, these laboratory measurements were compared to the same measurements at a real office building. Although the acoustic measurement uncertainty is still significant (greater than +/- 50%), the acoustic method has the potential to give an order of magnitude of single leak sizes.