Daniel Larrieu

Daniel Larrieu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2021 in Neurospine
Verified
Journal Article
Open access
PDF file
ABAnouar Bourghli
Anouar Bourghli
LBLouis BOISSIERE
Louis BOISSIERE
DKDavid Kieser
David Kieser
DLDaniel Larrieu
Daniel Larrieu
JPJavier Pizones
Javier Pizones
OGon behalf of the European Spine Study Group
on behalf of the European Spine Study Group
Objective: To compare the radiological and functional outcomes and complications of adult spinal deformity patients who underwent a pedicle subtraction osteotomy (PSO) below L2 but categorized according to their construct where either 2-rod or multiple-rod construct is applied.Methods: Sixty-seven patients met the inclusion criteria, and were categorized into 3 groups: 2 rods (2R), multiple rods around the PSO (MRP), multiple rods around the PSO and lumbosacral junction (MRL). Demographic data, operative parameters, spinopelvic parameters, functional outcomes, and complications were collected.Results: Health-related quality of life scores showed a better outcome at 6 months and last follow-up visits in the MRP and MRL groups which were noted on different domains of Scoliosis Research Society-22 questionnaire, 36-item Short Form Health Surve, and Oswestry Disability Index scores (p < 0.05). The 3 groups showed similar rates of rod-related complications with no significant difference (p = 0.95). And inside each group, distribution of complications between pseudarthrosis with revision and rod fracture without revision was also similar (p = 0.99).Conclusion: The use of multiple rods across the PSO did not show a better outcome when compared to single rods in terms of incidence and types of mechanical complications. However, better postoperative coronal alignment and health-related quality of life scores in the multiple rods group could be seen demonstrating an improved functional outcome.

Verified
Journal Article
Open access
PDF file
JPJavier Pizones
Javier Pizones
LMLucía Moreno-Manzanaro
Lucía Moreno-Manzanaro
APAnika Pupak
Anika Pupak
SNSusana Núñez-Pereira
Susana Núñez-Pereira
DLDaniel Larrieu
Daniel Larrieu
OEOn Behalf Of The Essg
On Behalf Of The Essg
Background: Advancements in non-ionizing methods for quantifying spinal deformities are crucial for assessing and monitoring scoliosis. In this study, we analyzed the observer variability of a newly developed digital tool for quantifying body asymmetry from clinical photographs. Methods: Prospective observational multicenter study. Initially, a digital tool was developed using image analysis software, calculating quantitative measures of body asymmetry. This tool was integrated into an online platform that exports data to a database. The tool calculated 10 parameters, including angles (shoulder height, axilla height, waist height, right and left waistline angles, and their difference) and surfaces of the left and right hemitrunks (shoulders, waists, pelvises, and total). Subsequently, an online training course on the tool was conducted for twelve observers not involved in its development (six research coordinators and six spine surgeons). Finally, 15 standardized back photographs of adolescent idiopathic scoliosis patients were selected from a multicenter image bank, representing various clinical scenarios (different age, gender, curve type, BMI, and pre- and postoperative images). The 12 observers measured the photographs at two different times with a three-week interval. For the second round, the images were randomly mixed. Inter- and intra-observer variabilities of the measurements were analyzed using intraclass correlation coefficients (ICCs), and reliability was measured by the standard error of measurement (SEM). Group comparisons were made using Student’s t-test. Results: The mean inter-observer ICC for the ten measurements was 0.981, the mean intra-observer ICC was 0.937, and SEM was 0.3–1.3°. The parameter with the strongest inter- and intra-observer validity was the difference in waistline angles 0.994 and 0.974, respectively, while the highest variability was found with the waist height angle 0.963 and 0.845, respectively. No test–retest differences (p > 0.05) were observed between researchers (0.948 ± 0.04) and surgeons (0.925 ± 0.05). Conclusion: We developed a new digital tool integrated into an online platform demonstrating excellent reliability and inter- and intra-observer variabilities for quantifying body asymmetry in scoliosis patients from a simple clinical photograph. The method could be used for assessing and monitoring scoliosis and body asymmetry without radiation.

30 April 2019 in Spine Deformity
Verified
Journal Article
Closed access
DKD.C. Kieser
D.C. Kieser
LBLouis BOISSIERE
Louis BOISSIERE
DCD.T. Cawley
D.T. Cawley
DLDaniel Larrieu
Daniel Larrieu
CYC. Yilgor
C. Yilgor
IOIbrahim Obeid
Ibrahim Obeid

11 April 2025 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
ABAlice Baroncini
Alice Baroncini
MJMelissa Bou Jaoude
Melissa Bou Jaoude
LBLouis Boissière
Louis Boissière
ABAnouar Bourghli
Anouar Bourghli
AAAhmet Alanay
Ahmet Alanay
IOIbrahim Obeid
Ibrahim Obeid

26 December 2023 in Children
Verified
Journal Article
Open access
PDF file
LBLouis BOISSIERE
Louis BOISSIERE
ABAnouar Bourghli
Anouar Bourghli
FGFernando Guevara-Villazon
Fernando Guevara-Villazon
FPFerran Pellise
Ferran Pellise
AAAhmet Alanay
Ahmet Alanay
IOIbrahim Obeid
Ibrahim Obeid
Introduction: Surgery to correct spinal deformities in scoliosis involves the use of contoured rods to reshape the spine and correct its curvatures. It is crucial to bend these rods appropriately to achieve the best possible correction. However, there is limited research on how the rod bending process relates to spinal shape in adolescent idiopathic scoliosis surgery. Methods: A retrospective study was conducted using a prospective multicenter scoliosis database. This study included adolescent idiopathic scoliosis patients from the database who underwent surgery with posterior instrumentation covering the T4 to T12 segments. Standing global spine X-rays were used in the analysis. The sagittal Cobb angles between T5 and T11 were measured on the spine. Additionally, the curvature of the rods between T5 and T11 was measured using the tangent method. To assess the relationship between these measurements, the difference between the dorsal kyphosis (TK) and the rod kyphosis (RK) was calculated (ΔK = TK − RK). This study aimed to analyze the correlation between ΔK and various patient characteristics. Both descriptive and statistical analyses were performed to achieve this goal. Results: This study encompassed a cohort of 99 patients, resulting in a total of 198 ΔK measurements for analysis. A linear regression analysis was conducted, revealing a statistically significant positive correlation between the kyphosis of the rods and that of the spine (r = 0.77, p = 0.0001). On average, the disparity between spinal and rod kyphosis averaged 5.5°. However, it is noteworthy that despite this modest mean difference, there was considerable variability among the patients. In particular, in 84% of cases, the concave rod exhibited less kyphosis than the spine, whereas the convex rod displayed greater kyphosis than the spine in 64% of cases. It was determined that the primary factor contributing to the flattening of the left rod was the magnitude of the coronal Cobb angle, both before and after the surgical procedure. These findings emphasize the importance of considering individual patient characteristics when performing rod bending procedures, aiming to achieve the most favorable outcomes in corrective surgery. Conclusions: Although there is a notable and consistent correlation between the curvature of the spine and the curvature of the rods, it is important to acknowledge the substantial heterogeneity observed in this study. This heterogeneity suggests that individual patient factors play a significant role in shaping the outcome of spinal corrective surgery. Furthermore, this study highlights that more severe spinal curvatures in the frontal plane have an adverse impact on the shape of the rods in the sagittal plane. In other words, when the scoliosis curve is more pronounced in the frontal plane, it tends to influence the way the rods are shaped in the sagittal plane. This underscores the complexity of spinal deformities and the need for a tailored approach in surgical interventions to account for these variations among patients.