Combined non-destructive evaluation methods for fused silica’s damage precursors including UV photothermal weak absorption, ultrafast fluorescence, steady-state fluorescence, Raman spectroscopy, and stress distribution, are proposed to explain the damage mechanism from multiple perspectives. The correlation between each non-destructive characterization method and damage behaviors is simultaneously verified, in general, the damage threshold test of R on 1. The results have shown that regions with high photothermal absorption are accompanied by low damage thresholds, because the photothermal conversion process is associated with laser-induced damage. The damage threshold is also lower at locations of bright ultrafast fluorescence signals with a lifetime ranging from 1.2∼3 ns, as ultrafast fluorescence is associated with high densities of defects. A complementary relationship between the distribution of ultrafast fluorescence and the distribution of photothermal absorption signals is constructed. This indicates that the steady-state fluorescence cannot accurately evaluate the precursor’s damage performance. Furthermore, Raman spectroscopy is utilized to identify the structural changes in bond lengths and angles, as well as locations of damages coinciding with stress distribution.
In this paper, we investigate the theory of energy distribution when divergent light undergoes harmonic conversion in KDP crystals, and based on this theory, we design and construct a precision measuring instrument for the detuning angle of (KDP) Crystals (MIDC). The device can obtain the detuning angle of the crystal by a single measurement with an average measurement error of 72.78 urad. At the same time, it also has the function of scanning the full aperture of the crystals. Using the MIDC, it is possible to quickly measure the KDP crystal at a single point and quickly scan the crystal detuning angle at full aperture. In addition, we conduct a theoretical study on the variation of detuning angle caused by gravity-influencing factors under online conditions, propose an optimization formula for the offline measurement results of detuning angle, and calculate the optimized values of detuning angle for two kinds of crystals under 45° online conditions. We finally study the error source of the MIDC device, analyze the trend of the influence of positioning errors of the crystal and optical elements on the detuning angle measurement results, and provide theoretical support for the error monitoring and correction of MIDC.