Mabroor Ahmed

Mr. Mabroor Ahmed

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
FTFranziska Treibel
Franziska Treibel
MNMai Nguyen
Mai Nguyen
MAMabroor Ahmed
Mabroor Ahmed
ADAnnique Dombrowsky
Annique Dombrowsky
JWJan J. Wilkens
Jan J. Wilkens
Stefan BartzschStefan Bartzsch
Stefan Bartzsch

28 January 2022 in Cancers
Verified
Journal Article
Open access
PDF file
KKKim Melanie Kraus
Kim Melanie Kraus
JWJohanna Winter
Johanna Winter
YZYating Zhang
Yating Zhang
MAMabroor Ahmed
Mabroor Ahmed
SCStephanie Combs
Stephanie Combs
Stefan BartzschStefan Bartzsch
Stefan Bartzsch
Microbeam radiotherapy (MRT) is a novel, still preclinical dose delivery technique. MRT has shown reduced normal tissue effects at equal tumor control rates compared to conventional radiotherapy. Treatment planning studies are required to permit clinical application. The aim of this study was to establish a dose comparison between MRT and conventional radiotherapy and to identify suitable clinical scenarios for future applications of MRT. We simulated MRT treatment scenarios for clinical patient data using an inhouse developed planning algorithm based on a hybrid Monte Carlo dose calculation and implemented the concept of equivalent uniform dose (EUD) for MRT dose evaluation. The investigated clinical scenarios comprised fractionated radiotherapy of a glioblastoma resection cavity, a lung stereotactic body radiotherapy (SBRT), palliative bone metastasis irradiation, brain metastasis radiosurgery and hypofractionated breast cancer radiotherapy. Clinically acceptable treatment plans were achieved for most analyzed parameters. Lung SBRT seemed the most challenging treatment scenario. Major limitations comprised treatment plan optimization and dose calculation considering the tissue microstructure. This study presents an important step of the development towards clinical MRT. For clinical treatment scenarios using a sophisticated dose comparison concept based on EUD and EQD2, we demonstrated the capability of MRT to achieve clinically acceptable dose distributions.

1 January 2025 in Cancers
Verified
Journal Article
Open access
PDF file
NSNarayani Subramanian
Narayani Subramanian
AČAleksandra Čolić
Aleksandra Čolić
Marina Santiago FrancoMarina Santiago Franco
Marina Santiago Franco
JSJessica Patrice Stolz
Jessica Patrice Stolz
MAMabroor Ahmed
Mabroor Ahmed
TSThomas E. Schmid
Thomas E. Schmid
Objectives: The present study aimed to compare the tumor growth delay between conventional radiotherapy (CRT) and the spatially fractionated modalities of microbeam radiation therapy (MRT) and minibeam radiation therapy (MBRT). In addition, we also determined the influence of beam width and the peak-to-valley dose ratio (PVDR) on tumor regrowth. Methods: A549, a human non-small-cell lung cancer cell line, was implanted subcutaneously into the hind leg of female CD1-Foxn1nu mice. The animals were irradiated with sham, CRT, MRT, or MBRT. The spatially fractionated fields were created using two specially designed multislit collimators with a beam width of 50 μm and a center-to-center distance (CTC) of 400 μm for MRT and a beam width of 500 μm and 2000 μm CTC for MBRT. Additionally, the concept of the equivalent uniform dose (EUD) was chosen in our study. A dose of 20 Gy was applied to all groups with a PVDR of 20 for MBRT and MRT. Tumor growth was recorded until the tumors reached at least a volume that was at least three-fold of their initial value, and the growth delay was calculated. Results: We saw a significant reduction in tumor regrowth following all radiation modalities. A growth delay of 11.1 ± 8 days was observed for CRT compared to the sham, whereas MBRT showed a delay of 20.2 ± 7.3 days. The most pronounced delay was observed in mice irradiated with MRT PVDR 20, with 34.9 ± 26.3 days of delay. Conclusions: The current study highlights the fact that MRT and MBRT modalities show a significant tumor growth delay in comparison to CRT at equivalent uniform doses.

30 January 2024 in Cancers
Verified
Journal Article
Open access
PDF file
MAMabroor Ahmed
Mabroor Ahmed
SBSandra Bicher
Sandra Bicher
SCStephanie Combs
Stephanie Combs
RLRainer Lindner
Rainer Lindner
SRSusanne Raulefs
Susanne Raulefs
Stefan BartzschStefan Bartzsch
Stefan Bartzsch
Microbeam radiation therapy (MRT) is a still pre-clinical form of spatially fractionated radiotherapy, which uses an array of micrometer-wide, planar beams of X-ray radiation. The dose modulation in MRT has proven effective in the treatment of tumors while being well tolerated by normal tissue. Research on understanding the underlying biological mechanisms mostly requires large third-generation synchrotrons. In this study, we aimed to develop a preclinical treatment environment that would allow MRT independent of synchrotrons. We built a compact microbeam setup for pre-clinical experiments within a small animal irradiator and present in vivo MRT application, including treatment planning, dosimetry, and animal positioning. The brain of an immobilized mouse was treated with MRT, excised, and immunohistochemically stained against γH2AX for DNA double-strand breaks. We developed a comprehensive treatment planning system by adjusting an existing dose calculation algorithm to our setup and attaching it to the open-source software 3D-Slicer. Predicted doses in treatment planning agreed within 10% with film dosimetry readings. We demonstrated the feasibility of MRT exposures in vivo at a compact source and showed that the microbeam pattern is observable in histological sections of a mouse brain. The platform developed in this study will be used for pre-clinical research of MRT.

10 March 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
JSJessica Patrice Stolz
Jessica Patrice Stolz
KRKristina Rogal
Kristina Rogal
SBSandra Bicher
Sandra Bicher
JWJohanna Winter
Johanna Winter
MAMabroor Ahmed
Mabroor Ahmed
TSThomas E. Schmid
Thomas E. Schmid
Background: Microbeam radiation therapy (MRT) is an advanced preclinical approach in radiotherapy that utilizes spatially fractionated dose distributions by collimating x-rays into micrometer-wide, planar beams. While the benefits of temporal fractionation are well established and widely incorporated into conventional radiotherapy protocols, the interplay between MRT and temporal dose fractionation remains largely unexplored. In this study, we investigate the effects of combining temporal and spatial dose fractionation by assessing clonogenic cell survival following temporally fractionated MRT with varying irradiation angles, compared to conventional broad-beam (BB) irradiation. Methods: A lung tumor cell line (A549) and a normal lung cell line (MRC-5) were irradiated with a total number of four fractions with a 24 h interval between each fraction. We compared a temporally fractionated BB regime to two temporally fractionated MRT schemes with either overlapping MRT fields or MRT fields with a 45° rotation per fraction. Subsequently, the clonogenic cell survival assay was used by analyzing the corresponding survival fractions (SFs). Results: The clonogenic survival of A549 tumor cells differed significantly between microbeam radiation therapy with rotation (MRT + R) and overlapping MRT. However, neither MRT + R nor overlapping MRT showed statistically significant differences compared to the broad-beam (BB) irradiation for A549. In contrast, the normal tissue cell line MRC-5 exhibited significantly higher clonogenic survival following both MRT + R and overlapping MRT compared to BB. Conclusions: This study demonstrates that combining temporal and spatial fractionation enhances normal tissue cell survival while maintaining equivalent tumor cell kill, potentially increasing the therapeutic index. Our findings support the feasibility of delivering temporally fractionated doses using different MRT modalities and provide clear evidence of the therapeutic benefits of temporally fractionated MRT.

11 March 2026 in Cells
Verified
Journal Article
Open access
PDF file
AČAleksandra Čolić
Aleksandra Čolić
Marina Santiago FrancoMarina Santiago Franco
Marina Santiago Franco
NSNarayani Subramanian
Narayani Subramanian
MAMabroor Ahmed
Mabroor Ahmed
SRSusanne Raulefs
Susanne Raulefs
HSHarry Scherthan
Harry Scherthan
Radiotherapy (RT) is a standard treatment for lung cancer; however, radiation-induced toxicities such as pneumonitis and fibrosis limit dose escalation and tumor control. Therefore, improved RT approaches are needed. This study investigated the radiation response of human ex vivo normal lung tissue using the three-dimensional EpiAlveolar™ model. Tissue models were irradiated with broad-beam (BB) and two spatially fractionated microbeam radiation therapy (MRT) dose metrics: equivalent uniform dose (MRT-EUD) and valley dose (MRT-valley). Our findings show that ex vivo lung tissue is able to tolerate peak doses of 36 Gy following MRT-EUD. On day 21, models effectively repaired significant DNA double-strand break (DSB) damage seen in the MRT-EUD-irradiated peak regions. In contrast, persistent unresolved DSBs were detected in MRT-valley-irradiated models 21 days post irradiation. Prolonged culture time resulted in cell loss and a reduction in epithelial cell layers. A significant upregulation of the pro-inflammatory cytokine IL6 was observed in both BB and MRT-EUD groups at 21 days. Fibrotic collagen deposition was detected in one BB-irradiated model but was absent in remaining BB- and MRT-treated tissues. Further investigation is required to clarify the potential and suitability of EpiAlveolar™ models for studying radiation-induced lung injury.