Mattia Antonelli

Dr. Mattia Antonelli

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2020 in Robotics
Verified
Journal Article
Open access
PDF file
Elisa DigoElisa Digo
Elisa Digo
MAMattia Antonelli
Mattia Antonelli
Valerio CornagliottoValerio Cornagliotto
Valerio Cornagliotto
SPStefano Pastorelli
Stefano Pastorelli
LGLaura Gastaldi
Laura Gastaldi
(1) Background: The technologies of Industry 4.0 are increasingly promoting an operation of human motion prediction for improvement of the collaboration between workers and robots. The purposes of this study were to fuse the spatial and inertial data of human upper limbs for typical industrial pick and place movements and to analyze the collected features from the future perspective of collaborative robotic applications and human motion prediction algorithms. (2) Methods: Inertial Measurement Units and a stereophotogrammetric system were adopted to track the upper body motion of 10 healthy young subjects performing pick and place operations at three different heights. From the obtained database, 10 features were selected and used to distinguish among pick and place gestures at different heights. Classification performances were evaluated by estimating confusion matrices and F1-scores. (3) Results: Values on matrices diagonals were definitely greater than those in other positions. Furthermore, F1-scores were very high in most cases. (4) Conclusions: Upper arm longitudinal acceleration and markers coordinates of wrists and elbows could be considered representative features of pick and place gestures at different heights, and they are consequently suitable for the definition of a human motion prediction algorithm to be adopted in effective collaborative robotics industrial applications.

21 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MAMattia Antonelli
Mattia Antonelli
ECElena Caselli
Elena Caselli
LGLaura Gastaldi
Laura Gastaldi
The goal of this study is to compare gait smoothness using different metrics. Methodologically, harmonic ratio (HR), spectral arc length (SPARC) and log dimensionless jerk (LDLJ) metrics were applied to acceleration and angular velocity data collected during gait using a wearable inertial sensor placed on the trunk. Sixteen healthy elderly (68.3 ± 4.4 years) and sixteen young (22.6 ± 1.1 years) participants volunteered for the analysis. They were requested to walk at self-selected normal and fast velocities. The results obtained with the three metrics showed variations in smoothness within and between groups. Notably, the older group exhibited contradictory smoothness trends compared to prior studies, presenting a smoother gait than the younger cohort, except for specific directional accelerations. Contradictory outcomes arose between metrics, challenging the influence of age on gait smoothness. Despite concerns about LDLJ’s susceptibility to disturbances, it emerged as the most robust metric. Conversely, HR exhibited alignment with the existing literature on specific acceleration directions. The differences observed in gait smoothness between the two age groups while walking at different speeds suggest that pace might affect smoothness evaluation. The study posits that aging may have a less pronounced impact on gait smoothness compared to cognitive impairment, implying potential clinical utility in discerning age-related gait changes. These findings highlighted the importance of a comprehensive approach to estimating gait smoothness, integrating different metrics and considering several walking speeds, crucial for understanding age-related gait alterations and their clinical implications.

6 August 2022
Verified
Book Chapter
Closed access
PDF file
MAMattia Antonelli
Mattia Antonelli
EPElisa Panero
Elisa Panero
MPMichele Polito
Michele Polito
LGLaura Gastaldi
Laura Gastaldi
SPStefano Pastorelli
Stefano Pastorelli

2 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Elisa DigoElisa Digo
Elisa Digo
ECElena Caselli
Elena Caselli
MPMichele Polito
Michele Polito
MAMattia Antonelli
Mattia Antonelli
LGLaura Gastaldi
Laura Gastaldi
SPStefano Pastorelli
Stefano Pastorelli
The importance of performance excellence and operator’s safety is fundamental not only when operators perform repetitive and controlled industrial tasks, but also in case of abrupt gestures due to inattention and unexpected circumstances. Since optical systems work at frequencies that are too low and they are not able to detect gestures as early as possible, combining the use of wearable magneto-inertial measurement units (MIMUs) with the adoption of deep learning techniques can be useful to instruct the machine about human motion. To improve the initial training phase of neural networks for high classification performance, gesture repeatability over time has to be verified. Since the test–retest approach has been poorly applied based on MIMUs signals in a context of human–machine interaction, the aim of this work was to evaluate the repeatability of pick-and-place gestures composed of both normal and abrupt movements. Overall, results demonstrated an excellent test–retest repeatability for normal movements and a fair-to-good test–retest repeatability for abrupt movements. In addition, results suggested important information about the application of deep learning to identify the types of movements: the test showed how to improve reinforcement learning for the identification of onset gestures, whereas the retest allowed for defining the time necessary to retrain the network.

20 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Elisa DigoElisa Digo
Elisa Digo
ECElena Caselli
Elena Caselli
MPMichele Polito
Michele Polito
MAMattia Antonelli
Mattia Antonelli
LGLaura Gastaldi
Laura Gastaldi
SPStefano Pastorelli
Stefano Pastorelli
The importance of performance excellence and operator’s safety is fundamental not only when operators perform repetitive and controlled industrial tasks, but also in case of abrupt gestures due to inattention and unexpected circumstances. Since optical systems work at too low frequencies and they are not able to detect gestures as early as possible, combining the use of wearable magneto-inertial measurement units (MIMUs) with the adoption of deep learning techniques can be useful to instruct the machine about human motion. To improve the initial training phase of neural networks for high classification performance, gestures repeatability over time has to be verified. Since test-retest approach has been poorly applied based on MIMUs signals in a context of human-machine interaction, the aim of this work was to evaluate the repeatability of pick-and-place gestures composed of both normal and abrupt movements. Overall, results demonstrated an excellent test-retest repeatability for normal movements and a fair-to-good test-retest repeatability for abrupt movements. Moreover whereas the reduction of time between test and retest sessions increased repeatability indices.. In detail, results of the test suggested how to improve the reinforcement learning for the identification of gestures onset, whereas results of the retest gave important information about the time necessary to retrain the network.

19 May 2023
Verified
Book Chapter
Closed access
PDF file
MAMattia Antonelli
Mattia Antonelli
ECElena Caselli
Elena Caselli
LGLaura Gastaldi
Laura Gastaldi
LJLuc Janssens
Luc Janssens
SPStefano Pastorelli
Stefano Pastorelli
YVYves Vanlandewijck
Yves Vanlandewijck