Laura Gastaldi

Dr. Laura Gastaldi

Department of Mathematical Sciences, Politecnico di Torino, Torino, Italy
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MGMarco GHISLIERI
Marco GHISLIERI
LGLaura Gastaldi
Laura Gastaldi
SPStefano Pastorelli
Stefano Pastorelli
STShigeru Tadano
Shigeru Tadano
Valentina AgostiniValentina Agostini
Valentina Agostini
Wearable sensors are de facto revolutionizing the assessment of standing balance. The aim of this work is to review the state-of-the-art literature that adopts this new posturographic paradigm, i.e., to analyse human postural sway through inertial sensors directly worn on the subject body. After a systematic search on PubMed and Scopus databases, two raters evaluated the quality of 73 full-text articles, selecting 47 high-quality contributions. A good inter-rater reliability was obtained (Cohen’s kappa = 0.79). This selection of papers was used to summarize the available knowledge on the types of sensors used and their positioning, the data acquisition protocols and the main applications in this field (e.g., “active aging”, biofeedback-based rehabilitation for fall prevention, and the management of Parkinson’s disease and other balance-related pathologies), as well as the most adopted outcome measures. A critical discussion on the validation of wearable systems against gold standards is also presented.

5 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
RTRyo Takeda
Ryo Takeda
GLGiulia Lisco
Giulia Lisco
TFTadashi Fujisawa
Tadashi Fujisawa
LGLaura Gastaldi
Laura Gastaldi
HTHarukazu Tohyama
Harukazu Tohyama
STShigeru Tadano
Shigeru Tadano
Accumulated signal noise will cause the integrated values to drift from the true value when measuring orientation angles of wearable sensors. This work proposes a novel method to reduce the effect of this drift to accurately measure human gait using wearable sensors. Firstly, an infinite impulse response (IIR) digital 4th order Butterworth filter was implemented to remove the noise from the raw gyro sensor data. Secondly, the mode value of the static state gyro sensor data was subtracted from the measured data to remove offset values. Thirdly, a robust double derivative and integration method was introduced to remove any remaining drift error from the data. Lastly, sensor attachment errors were minimized by establishing the gravitational acceleration vector from the acceleration data at standing upright and sitting posture. These improvements proposed allowed for removing the drift effect, and showed an average of 2.1°, 33.3°, 15.6° difference for the hip knee and ankle joint flexion/extension angle, when compared to without implementation. Kinematic and spatio-temporal gait parameters were also calculated from the heel-contact and toe-off timing of the foot. The data provided in this work showed potential of using wearable sensors in clinical evaluation of patients with gait-related diseases.

21 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Valentina AgostiniValentina Agostini
Valentina Agostini
LGLaura Gastaldi
Laura Gastaldi
VRValeria Rosso
Valeria Rosso
MKMarco KNAFLITZ
Marco KNAFLITZ
STShigeru Tadano
Shigeru Tadano
Background: Wearable magneto-inertial sensors are being increasingly used to obtain human motion measurements out of the lab, although their performance in applications requiring high accuracy, such as gait analysis, are still a subject of debate. The aim of this work was to validate a gait analysis system (H-Gait) based on magneto-inertial sensors, both in normal weight (NW) and overweight/obese (OW) subjects. The validation is performed against a reference multichannel recording system (STEP32), providing direct measurements of gait timings (through foot-switches) and joint angles in the sagittal plane (through electrogoniometers). Methods: Twenty-two young male subjects were recruited for the study (12 NW, 10 OW). After positioning body-fixed sensors of both systems, each subject was asked to walk, at a self-selected speed, over a 14-m straight path for 12 trials. Gait signals were recorded, at the same time, with the two systems. Spatio-temporal parameters, ankle, knee, and hip joint kinematics were extracted analyzing an average of 89 ± 13 gait cycles from each lower limb. Intraclass correlation coefficient and Bland-Altmann plots were used to compare H-Gait and STEP32 measurements. Changes in gait parameters and joint kinematics of OW with respect NW were also evaluated. Results: The two systems were highly consistent for cadence, while a lower agreement was found for the other spatio-temporal parameters. Ankle and knee joint kinematics is overall comparable. Joint ROMs values were slightly lower for H-Gait with respect to STEP32 for the ankle (by 1.9° for NW, and 1.6° for OW) and for the knee (by 4.1° for NW, and 1.8° for OW). More evident differences were found for hip joint, with ROMs values higher for H-Gait (by 6.8° for NW, and 9.5° for OW). NW and OW showed significant differences considering STEP32 (p = 0.0004), but not H-Gait (p = 0.06). In particular, overweight/obese subjects showed a higher cadence (55.0 vs. 52.3 strides/min) and a lower hip ROM (23.0° vs. 27.3°) than normal weight subjects. Conclusions: The two systems can be considered interchangeable for what concerns joint kinematics, except for the hip, where discrepancies were evidenced. Differences between normal and overweight/obese subjects were statistically significant using STEP32. The same tendency was observed using H-Gait.

1 January 2012 in Clinical Journal of Sport Medicine
Verified
Journal Article
Closed access
LGLaura Gastaldi
Laura Gastaldi
SPStefano Pastorelli
Stefano Pastorelli
SFStefano Frassinelli
Stefano Frassinelli
Objective To analyze the biomechanics of the double poling (DP) gesture in cross-country disabled sit-skiers in the field during competition. Design Cross-sectional research. Setting One-kilometer sprint race, Winter Paralympic Games, Vancouver 2010, Canada. Participants Paralympic athletes: 35 men and 15 women, classified in all the 5 classes of the sit-skier category. Intervention Elite sit-skiers, with different disabilities, were recorded with a high-speed markerless stereophotogrammetric camera system. Reference points were semiautomatically tracked frame-by-frame on video images, according to a biomechanical model consisting of 7 anatomical and 4 technical points. Main Outcome Measures Coordinates of anatomical and technical points were evaluated for 2-dimensional kinematic analysis of the push gesture both with reference to a ground-fixed frame and with respect to the athletes' seat on the sledges. Results Several graphical results represent the development of the DP gesture of each athlete with respect to both ground reference frame and sledge reference frame. The progression of the gesture is depicted by body and pole stick diagrams, trends of reference point positions and their gradients, and body joint trajectories in space. In addition, kinematic biomechanical parameters (eg, joints' range of motion) and technical parameters (eg, pole incline, sledge velocity) are reported. Conclusions This research demonstrates the feasibility of a markerless kinematic analysis of the poling gesture on a contest field. Results point out a wide variability of the gesture due to the residual functional capabilities and sitting postures of each athlete. However, the poling cycles of subjects classified into different classes present similar features. An original segmentation of the DP gesture in a sequence of 3 phases is proposed in the article.

28 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
VRValeria Rosso
Valeria Rosso
Valentina AgostiniValentina Agostini
Valentina Agostini
RTRyo Takeda
Ryo Takeda
STShigeru Tadano
Shigeru Tadano
LGLaura Gastaldi
Laura Gastaldi
Overweight/obesity is a physical condition that affects daily activities, including walking. The main purpose of this study was to identify if there is a relationship between body mass index (BMI) and gait characteristics in young adults. 12 normal weight (NW) and 10 overweight/obese (OW) individuals walked at a self-selected speed along a 14 m indoor path. H-Gait system, combining seven inertial sensors (fixed on pelvis and lower limbs), was used to record gait data. Walking speed, spatio-temporal parameters and joint kinematics in 3D were analyzed. Differences between NW and OW and correlations between BMI and gait parameters were evaluated. Conventional spatio-temporal parameters did not show statistical differences between the two groups or correlations with the BMI. However, significant results were pointed out for the joint kinematics. OW showed greater hip joint angles in frontal and transverse planes, with respect to NW. In the transverse plane, OW showed a greater knee opening angle and a shorter length of knee and ankle trajectories. Correlations were found between BMI and kinematic parameters in the frontal and transverse planes. Despite some phenomena such as soft tissue artifact and kinematics cross-talk, which have to be more deeply assessed, current results show a relationship between BMI and gait characteristics in young adults that should be looked at in osteoarthritis prevention.

2 December 2022 in Robotics
Verified
Journal Article
Open access
PDF file
Elisa DigoElisa Digo
Elisa Digo
SPStefano Pastorelli
Stefano Pastorelli
LGLaura Gastaldi
Laura Gastaldi
Industry 4.0 has promoted the concept of automation, supporting workers with robots while maintaining their central role in the factory. To guarantee the safety of operators and improve the effectiveness of the human-robot interaction, it is important to detect the movements of the workers. Wearable inertial sensors represent a suitable technology to pursue this goal because of their portability, low cost, and minimal invasiveness. The aim of this narrative review was to analyze the state-of-the-art literature exploiting inertial sensors to track the human motion in different industrial scenarios. The Scopus database was queried, and 54 articles were selected. Some important aspects were identified: (i) number of publications per year; (ii) aim of the studies; (iii) body district involved in the motion tracking; (iv) number of adopted inertial sensors; (v) presence/absence of a technology combined to the inertial sensors; (vi) a real-time analysis; (vii) the inclusion/exclusion of the magnetometer in the sensor fusion process. Moreover, an analysis and a discussion of these aspects was also developed.