Evangelos Dimitriou

Dr. Evangelos Dimitriou

Department of Natural Resources Management and Agricultural Engineering, Agricultural University of Athens, Athens, Attikí, Greece
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Desalination and Water Treatment
Verified
Journal Article
Open access
Evangelos DimitriouEvangelos Dimitriou
Evangelos Dimitriou
EMEssam Sh. Mohamed
Essam Sh. Mohamed
George KyriakarakosGeorge Kyriakarakos
George Kyriakarakos
George PapadakisGeorge Papadakis
George Papadakis
Sea water reverse osmosis (SWRO) desalination constitutes a successful technology for covering the potable water needs of islands and coastal regions. SWRO units can be combined with renewable energy technologies such as photovoltaic and wind generators. Conventional small scale SWRO units are not often combined with energy recovery devices; however, these devices can decrease drastically the energy consumption of the SWRO units. Furthermore, in the literature there are references which prove that the operation of a desalination unit in part-load conditions can result in lower specific energy consumption compared to full-load operation. This paper presents the simulation and the experimental investigation under full- and part-load conditions of an existing SWRO desalination unit (50 mS/cm feed water) in order for the desalination unit to be optimally utilized in a polygeneration microgrid topology which uses advanced energy management algorithms. The experimental operation of the SWRO Unit in part-load conditions is achieved by varying the speed of the motor—pump assembly, the pressure and the flow rate of the feed water. During the evaluation of the measurements result, an optimum operating window in the range of 40–57 bar was drawn regarding the operation of the SWRO desalination unit in part- and full-load conditions. More specifically, in this pressure range the average value of fresh water production was 60 L/h with an acceptable fresh water electrical conductivity of 550 μS/cm, and with a specific energy consumption range from 6.1 to 7.7 kWh/m3. With these results the operational parameters of the polygeneration microgrid energy management system can be optimized.

12 February 2025 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Open access
Evangelos DimitriouEvangelos Dimitriou
Evangelos Dimitriou
JCJorge Camacho-Espino
Jorge Camacho-Espino
AAAchilleas Anastasiou
Achilleas Anastasiou
George PapadakisGeorge Papadakis
George Papadakis

20 February 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Evangelos DimitriouEvangelos Dimitriou
Evangelos Dimitriou
DLDimitrios Loukatos
Dimitrios Loukatos
ETEleftherios Tampakakis
Eleftherios Tampakakis
Konstantinos G. ArvanitisKonstantinos G. Arvanitis
Konstantinos G. Arvanitis
George PapadakisGeorge Papadakis
George Papadakis
Considering the degradation of water resources and the increase in human population, desalination seems to be a promising method for meeting the global water demand, from potable water to plant irrigation needs. The contribution of desalination to the agricultural sector, through the supply of water for plants or animals, is critical because this sector represents 70% of the global water demand. Unfortunately, the desalination process is energy-intensive and subjected to several factors that result in undesirable fluctuations on quality/quantity of product water, and/or energy waste. Renewable energy sources can supply the necessary power, but they amplify these challenges because their availability varies over time. A simple and efficient way to tackle this issue is to control the pressure of the feed water before feeding it to the membrane. Typically, the pairing control systems are quite expensive or lack the necessary customization freedom that could improve their operation. Therefore, this study highlights the feasibility of enhancing a typical desalination control equipment via the incorporation of modern low-cost microcontrollers and flexible open-source software; the potential of these tools has not yet been fully explored. The microcontroller executes customized PID logic, driving an industrial inverter module. Our results indicate that the proposed system can keep pace with the desalination process setpoints, reducing the stress of the electromechanical components and periods of out-of-specification freshwater production. This low-level control function implementation minimizes the need for human intervention while providing a promising foundation for further extensions and customizations in this area.

4 April 2025 in Desalination and Water Treatment
Verified
Journal Article
Open access
JCJorge Camacho-Espino
Jorge Camacho-Espino
Evangelos DimitriouEvangelos Dimitriou
Evangelos Dimitriou
George PapadakisGeorge Papadakis
George Papadakis
GPG. Nicolás Marichal Plasencia
G. Nicolás Marichal Plasencia

20 January 2022
Verified
Journal Article
Open access
PDF file
Christos Spyridon KaravasChristos Spyridon Karavas
Christos Spyridon Karavas
Evangelos DimitriouEvangelos Dimitriou
Evangelos Dimitriou
Athanasios BalafoutisAthanasios Balafoutis
Athanasios Balafoutis
Dimitris ManolakosDimitris Manolakos
Dimitris Manolakos
George PapadakisGeorge Papadakis
George Papadakis
Access to fresh water is a major human right as mankind existence depends on it. The balance between fresh water supply and actual water demand for agricultural purposes (irrigation) relies on the availability of fresh water in the underground aquifers or surface water resources. Water resources are under great pressure due to the high demand for irrigation to sustain crop productivity and cover domestic use as a result of demographic growth. Desalination of sea or brackish water is one of the solutions to provide water for irrigation in remote areas of limited freshwater reserves. In such areas, if desalination is powered by renewable energy sources, then it can become a lot more sustainable. This paper presents the development of an innovative computational tool for the optimal (economically and technically) design of seawater reverse osmosis desalination systems for sustainable water production for crop irrigation. In order to further reduce the cost of water produced, an energy management and control system was also designed and included in the computational tool to ensure the optimal operation of the desalination plant. This system allows the seawater reverse osmosis unit to operate at variable load and determines its optimal operation point using computational intelligence techniques based on fuzzy cognitive maps. According to the results, the implementation of the computational tool for the design of PV-SWRO system presents the lowest cost as compared to the system designed with the conventional methodology.

16 December 2025 in Water
Verified
Journal Article
Open access
PDF file
Evangelos DimitriouEvangelos Dimitriou
Evangelos Dimitriou
DLDimitrios Loukatos
Dimitrios Loukatos
Konstantinos G. ArvanitisKonstantinos G. Arvanitis
Konstantinos G. Arvanitis
George PapadakisGeorge Papadakis
George Papadakis
The integration of Reverse Osmosis (RO) desalination with Renewable Energy (RE) sources offers a sustainable approach to freshwater production, particularly in remote and off-grid regions. However, the variable and intermittent output of RE power can cause operational instability that affects membrane performance and system reliability. This study experimentally evaluated a flat sheet seawater RO membrane under variable conditions emulating a Photovoltaic (PV)-powered system over three days. Three scenarios were examined: (i) steady full-load operation representing PV with battery storage, (ii) variable operation representing sunny-day PV output, and (iii) highly variable operation representing cloudy-day PV output. A Variable Frequency Drive (VFD) regulated by an Arduino microcontroller adjusted high-pressure pump operation in real time to replicate power fluctuations without energy storage. Each scenario operated for eight hours per day and was tested with and without end-of-day rinsing. Under the highly variable cloudy-day scenario without rinsing, water permeability decreased by 37%, salt rejection decreased by 18%, and membrane resistance increased by 37%, indicating compaction and fouling effects. Fourier Transform Infrared Spectroscopy with Attenuated Total Reflectance (FTIR-ATR) confirmed structural changes in membranes exposed to fluctuating conditions. These results highlight the need for improved operational strategies to protect membrane longevity in RE-powered desalination systems.