Shravan Shetty

Shravan Shetty


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2022 in Journal of Clinical Imaging Science
Verified
Journal Article
Open access
MMManpreet Manoj
Manpreet Manoj
LMLeeba Mathew
Leeba Mathew
SNSrikant Natarajan
Srikant Natarajan
SYShweta Yellapurkar
Shweta Yellapurkar
SSShravan Shetty
Shravan Shetty
SDSamarika Dahal
Samarika Dahal
Objective: The shape of the condyle, coronoid, and the intervening sigmoid notch is unique due to attachments and direction of pull of temporalis muscle, different chewing habits, hormones, etc. So morphometric variation of these mandibular landmarks can be used in individual identification. Material And Methods: The study was carried out on 500 panoramic view images. Visual tracing assisted assessment of thousand sides (left and right) was done. Sexual dimorphism of left and right mandibular ramus parts (sigmoid notch bordered by coronoid and condylar process). The shape of coronoid process, condyle, and sigmoid notch were interpreted. Results: The most prevalent shape of sigmoid notch was wide variant (41.2%), condyle was convex type (50%) and coronoid was round (53.4%). Condyle and coronoid showed asymmetry between right and left withp-value 0.001 and 0.019, respectively. This study has illustrated that triangular-shaped coronoid was more in females (p-value 0.012). Conclusion: Sexual dimorphism is observed in the shape of the mandible due to masticatory activity at the point of insertion of temporalis muscle, biting force, hormones, and various genetic reasons. The results have exemplified that the morphometric variation of condyle, coronoid and sigmoid notch can be used as a tool for personal identification.

11 March 2019 in Biomedical and Pharmacology Journal
Verified
Journal Article
Open access
PSPavithra Shettigar
Pavithra Shettigar
SSShravan Shetty
Shravan Shetty
RNRoopak D. Naik
Roopak D. Naik
SBShrinivas M. Basavaraddi
Shrinivas M. Basavaraddi
APAnand K. Patil
Anand K. Patil
This study aimed to assess the reliability of the android smartphone-based app OneCeph by comparing it with computer cephalometric tracing program Dolphin Imaging software. 50 cephalometric radiographs were randomly selected. On each cephalogram 20 landmarks were marked. 15 parameters indicating skeletal, dental and soft tissue parameters were selected and measured. The values obtained from Dolphin imaging software and the OneCeph app were compared with respect to the assessment of measurements of various parameters by paired t-test. It was observed that four parameters out of the fifteen showed significant differences between Dolphin imaging software and OneCeph app (p<0.05). For all the other parameters selected, no differences were observed between Dolphin and OneCeph digital methods and also there is a significant and positive correlation between the measures obtained from the Dolphin and OneCeph app for each landmark parameter. The results obtained by the OneCeph app showed most parameters are comparable with the Dolphin Imaging software. Therefore, it can be concluded that this app is reliable, user-friendly which facilitates its use by the clinician on a regular basis. This user-friendly OneCeph app can be utilized with sufficient accuracy for the cephalometric analysis of most of the measurements required in day-to-day clinical orthodontic practice.

26 July 2025 in 3 Biotech
Verified
Journal Article
Open access
PDF file
SNSrikant Natarajan
Srikant Natarajan
JAJunaid Ahmed
Junaid Ahmed
RSRuban Sundarraj
Ruban Sundarraj
VVVarenya Vinay
Varenya Vinay
SSShravan Shetty
Shravan Shetty
SCSunitha Carnelio
Sunitha Carnelio
This study evaluated the performance of three artificial intelligence (AI) algorithms—support vector machine (SVM), artificial neural network (ANN), and Random Forest (RF)—in sex estimation using 3D geometric morphometric data derived from nine permanent tooth classes in 120 individuals (60 males, 60 females). Dental casts from 60 males and 60 females, aged 13–20 were digitized using a 3D scanner. Anatomic and geometric landmarks were identified on nine tooth types (maxillary/mandibular premolars and molars) via 3D Slicer software. Landmark coordinates underwent Procrustes superimposition and principal component analysis. Three AI models (ANN, SVM, RF) were trained on pre-processed landmark data, with performance evaluated using fivefold cross validation, accuracy, precision, recall, F1-score, and AUC. RF outperformed SVM and ANN across all tooth types, achieving the highest accuracy (97.95% for mandibular second premolars) and balanced precision/recall (0.85–1.0). SVM showed moderate performance (70–88% accuracy), while ANN had the lowest metrics (58–70% accuracy). Maxillary first molars (95.83% accuracy) and mandibular second premolars (97.95%) exhibited the highest sexual dimorphism. RF demonstrated minimal sex bias, whereas ANN struggled with female classification (recall: 0.33–0.88 vs. males: 0.36–1.0). Feature analysis highlighted mandibular premolars as most dimorphic, with RF leveraging complex spatial relationships between landmarks effectively. Random Forest emerged as the most robust model for sex estimation using 3D dental landmarks, likely due to its ability to handle tabular data and high-dimensional feature spaces. Traditional machine learning models (RF, SVM) outperformed ANN, suggesting data set structure and feature engineering influence AI efficacy. These findings underscore AI’s potential to enhance objectivity and accuracy in forensic odontology, particularly with geometric morphometric data. Future research should explore hybrid models combining AI strengths with traditional morphometrics for improved reliability.

1 January 2024 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
SGS. Gupta
S. Gupta
SSShravan Shetty
Shravan Shetty
SNS. Natarajan
S. Natarajan
SNS. Nambiar
S. Nambiar
AMA. Mv
A. Mv
SAS. Agarwal
S. Agarwal
This study compared the accuracy and speed of cephalometric analysis using an artificial intelligence web-based method and a smartphone app-based system with manual cephalometric analysis as the reference standard. In this cross-sectional study, the lateral cephalograms were analysed using four methods: manual tracing, smartphone app tracing, artificial intelligence web-based automated tracing without manual landmark identification correction and artificial intelligence web-based automated tracing with manual landmark identification correction. The principal investigator obtained linear and angular cephalometric measurements to compare the accuracies of the four methods being assessed. Additionally, the duration required for landmark identification and subsequent analysis was recorded. The analyses included 40 lateral cephalograms that were selected based on the inclusion and exclusion criteria. Very good to excellent agreement was observed in the accuracies of the artificial intelligence web-based and smartphone app-based systems compared with manual tracing (interclass correlation coefficient values ranging from 0.707 to 0.9, p< 0.001). Of the artificial intelligence web-based systems, the method without correction of automated landmark detection showed less reliable measurements than the other methods. Cephalometric analysis using artificial intelligence web-based and smartphone app-based systems consumed less time than manual tracing (p< 0.001). Artificial intelligence web-based automated tracing with manual landmark identification correction and smartphone-based app provide results that are comparable to those from the manual tracing method. However, artificial intelligence web-based systems require improvements in terms of automated landmark identification to obtain results that are similar to those from the other methods being assessed. Key words:Artificial Intelligence, Cephalometry, Computer software, Mobile application.

12 January 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SNSrikant Natarajan
Srikant Natarajan
JAJunaid Ahmed
Junaid Ahmed
SSShravan Shetty
Shravan Shetty
NJNidhin Philip Jose
Nidhin Philip Jose
SCSharada Chowdappa
Sharada Chowdappa
KCKavery Chengappa
Kavery Chengappa
Background: Genetic and epigenetic alterations have significant impacts on the morphology of permanent mandibular premolars and molars. Geometric morphometry is a powerful technique, which can be utilized to identify specific landmarks that exhibit variation and that are associated with ancestry and dimorphism. Methods: The geometric and anatomic landmarks of mandibular premolars and molars were extracted from 3D digital replicas of diagnostic dental casts prepared for model analysis (n = 160). Tooth shape analysis was conducted using various techniques, including Procrustes superimposition, Procrustes ANOVA, discriminant function analysis, and the regression of shape over the centroid size. Results: Procrustes ANOVA showed that centroid size was not significantly different between the two sexes, but shape was significantly different in the two-cusp-type second premolars (p = 0.0035) and in the first/second molars (p < 0.001). The three-cusp type of the second premolars showed the highest degree of allometry, with 3.35%, followed by the mandibular second molars, with 3%, indicating that distal class types have a tendency to exhibit allometry. The distal and lingual components of the tooth showed more variability, and females tended to have sharper cusp configurations. Conclusions: This study shows how landmarks vary in permanent human post-canine dentition, a crucial finding for anatomic reconstruction and restorative dentistry. In particular, the molars and premolars of the mandible post-canine teeth are critical for achieving optimal masticatory efficiency and overall health. Additionally, a higher degree of allometry and the later formation of cusps correlate with greater shape variation, particularly on the distal and lingual sides. For precise restorative procedures, a thorough understanding of the anatomy of these teeth is required.

30 December 2021 in Biomedical and Pharmacology Journal
Verified
Journal Article
Open access
PKPriyanka Kenkare
Priyanka Kenkare
SSShravan Shetty
Shravan Shetty
UMUtkarsh Mangal
Utkarsh Mangal
AMAshith Mv
Ashith Mv
SSSiddarth Shetty
Siddarth Shetty
The first important step in orthodontic treatment is an accurate diagnosis and precise treatment planning to correct the malocclusion. This process entails a proper examination and understanding of the nature of malocclusion and the anomaly of the underlying structures. The emergence of three dimensional (3D) technology has transformed the field of orthodontics. The present article aims to take into account some of the applications of 3D technology in the field of orthodontics.