Background: Surface roughness associated with improper finishing/polishing of restorations can result in plaque accumulation, gingival irritation, surface staining, and poor esthetic of restored teeth. The study aimed to evaluate the efficiency of various finishing and polishing systems and time using various procedures on surface roughness of some esthetic restorative materials. Materials and Methods: In this in vitro study, samples of two composite materials, compomer and glass ionomer cement (GIC) materials, were fabricated. Finishing and polishing were done immediately (n = 40) and after 1 week (n = 40) using four systems (diamond bur + soflex discs; diamond bur + Astropol polishing brush; tungsten carbide bur + soflex discs; tungsten carbide bur + Astropol polishing brush). Surface roughness was measured using surface profilometer. Data were statistically analyzed by t-test (for each material and time period) and one-way analysis of variance followed by Tukey's post hoc (for finishing and polishing systems) at a significant level of P < 0.05. Results: Analysis of time period, irrespective of finishing and polishing system showed that Ra values were greater (P < 0.05) in delayed polishing in GIC > Z100 > Filtek P90 > Dyract AP, suggesting immediate polishing is better. Among the materials, Filtek P90 had the least Ra values indicating the smoothest surface among all materials, followed by Z100, Dyract AP, and GIC. Comparison of polishing and finishing systems irrespective of materials showed that Ra values were lower (P > 0.05) in diamond + Astropol combination whereas diamond + soflex had the greatest Ra values. Conclusion: It might be concluded that: (i) Filtek P90 showed least Ra values followed by < Z100 < Dyract < GIC; (ii) immediate (24 h) finishing/polishing of materials is better than delayed; and (iii) among all these polishing systems, diamond bur–Astropol and Astrobrush showed good surface finish.
Introduction. Temporomandibular disorders (TMDs) are a heterogeneous group of pathologies affecting the temporomandibular joint (TMJ), the jaw muscles, or both. Epidemiological studies of TMD reveal a prevalence of 82% in the general population with 48% of them presenting with clinical features of muscle tenderness and difficulty in mouth opening. TMD are considered to be the most common orofacial pain conditions of nondental origin. Methods. The patients with TMD were randomly divided into two groups, A and B, based on their VAS scale. Group A consists of two subgroups 1 and 2 each consisting of 15 patients. Group B consists of two subgroups 3 and 4 consisting of 15 patients. Patients in Group A were given TENS for twenty minutes, and the frequency is adjusted as follows: (i) subgroup 1: TENS frequency at a range of 0–5 (VAS measuring 1–5) and (ii) subgroup 2: TENS frequency at a range of 5 and above (VAS measuring 6–10). Patients in Group B were given MENS for twenty minutes, and the frequency adjusted as follows: (i) subgroup 3: MENS frequency at range of 0–5 (VAS measuring 1–5) and (ii) subgroup 4: MENS frequency at a range of 5 and above (VAS measuring 6–10). Each patient was recalled for five consecutive days for the treatment, and the same intensity and frequency were maintained throughout the treatment period. Results. The improvement in VAS is seen to be highly significant statistically in MENS subgroup 4 (moderate-to-severe pain). Subgroups 1 and 3 had improvement in VAS which was comparable in both TENS and MENS groups. Conclusion. In the present study, it was found that TENS and MENS are equally effective in improving the functional mouth opening. MENS showed better and immediate effect in relief of pain. Microcurrent also has the advantage of being subthreshold, and hence the side effects such as tingling sensation and paresthesia seen to occur in some patients following TENS are absent. TENS and MENS can be considered as the first line of treatment in patients with acute and chronic masticatory muscle pain and also as an effective treatment option in cases of functional mouth opening.
Background: Dental restorative materials are recognized as artificial niches that facilitate the adherence and accumulation of oral microorganisms. To mitigate oral diseases and extend the lifespan of restorations, it is advantageous to use dental materials that exhibit low susceptibility to bacterial adhesion. Objective: To evaluate and compare bacterial adhesion on two bioactive restorative materials, a glass hybrid restorative, and an alkasite with a nanohybrid resin composite as a positive control. The secondary objectives were to compare the surface roughness (SR) of the materials and determine the correlation between the bacterial adhesion and the SR. Materials and methods: The samples consisted of 33 polished discs of each material: Group A: Tetric® N-Ceram (nanohybrid resin composite), Group B: Equia Forte™ HT Fil (glass hybrid restorative) and Group C: Cention N® (alkasite). Streptococcus mutans cultures were inoculated and after 24-hours of incubation, bacterial adhesion was measured by measuring optical density (OD) and number of colony forming units (CFUs). After 96-hours incubation, the bacterial cell count was determined using scanning electron microscopy (SEM). SR was assessed using surface profilometer. Results: Alkasite had significantly lower OD and CFUs (p < 0.001 and p = 0.015 respectively). According to the SEM analysis, the glass hybrid restorative had lower mean bacterial cell count with no significant difference between the groups. The nanohybrid composite had the smoothest surface that was significantly lower than the alkasite and glass hybrid restorative (p = 0.002). None of the groups demonstrated a correlation between bacterial adhesion and SR. Conclusion: Alkasite impedes bacterial adhesion better than the glass hybrid restorative and nanohybrid composite, while smoother surfaces are achieved with the nanohybrid composite.
1 April 2010 in International Journal of Pediatric Otorhinolaryngology
The expiratory muscles are an indispensable component of respiratory function in critically ill patients, yet is often overlooked. We evaluated the association of abdominal expiratory muscles thickness pattern with weaning. This was a single-center, prospective observational study done on 81 adult mechanically ventilated patients who underwent the weaning process. Sixteen patients had simple weaning and 65 patients had either difficult or prolonged weaning. The mean and standard deviation (SD) of the thickness of expiratory abdominal muscles—rectus abdominis (RA), internal oblique (IO), external oblique (EO), and transversus abdominis (TA) were significantly more in patients with simple weaning than those with difficult or prolonged weaning. The receiver operating curve (ROC) of expiratory muscles showed RA, IO, EO, TA cut-offs 0.638, 0.492, 0.315, and 0.253 cm, respectively, to predict simple weaning. The pattern of expiratory muscle thickness RA > IO > EO > TA was maintained in both simple and difficult/prolonged weaning groups (p = 0.362). The ROC of diaphragmatic excursion (DE) for predicting simple weaning had cut-off 1.79 cm. The lung ultrasound score (LUS) was 5.75 ± 3.32 in the simple weaning group, compared to 9.71 ± 5.18 in the difficult/prolonged weaning group (p = 0.005). Abdominal expiratory muscles were significantly thicker in patients with simple weaning compared to those with difficult or prolonged weaning. The pattern of expiratory muscle thickness followed the pattern of RA > IO > EO > TA in both simple weaning and difficult or prolonged weaning groups. DE >1.79 cm predicted simple weaning and LUS was significantly lesser in patients with simple weaning (CTRI/2020/11/028895). Amara V, Vishwas P, Maddani SS, Natarajan S, Chaudhuri S. Evaluation of Abdominal Expiratory Muscle Thickness Pattern, Diaphragmatic Excursion, and Lung Ultrasound Score in Critically Ill Patients and Their Association with Weaning Patterns: A Prospective Observational Study. Indian J Crit Care Med 2022;26(3):307–313.