The increasing demand for sustainable and efficient energy storage materials has led to significant research into utilizing waste biomass for producing activated carbons. This study investigates the impact of the structural properties of activated carbons derived from various lignocellulosic biomasses—barley straw, wheat straw, and wheat bran—on the electrochemical performance of supercapacitors. The Fourier Transform Infrared (FTIR) spectroscopy analysis reveals the presence of key functional groups and their transformations during carbonization and activation processes. The Raman spectra provide detailed insights into the structural features and defects in the carbon materials. The electrochemical tests indicate that the activated carbon’s specific capacitance and energy density are influenced by the biomass source. It is shown that the wheat-bran-based electrodes exhibit the highest performance. This research demonstrates the potential of waste-biomass-derived activated carbons as high-performance materials for energy storage applications, contributing to sustainable and efficient supercapacitor development.
The development of neutron imaging facilities provides a growing range of applications in different research fields. The significance of the obtained structural information, among others, depends on the reliability of phase segmentation. We focused on the problem of pore segmentation in low-resolution images and tomography data, taking into consideration possible image corruption in the neutron tomography experiment. Two pore segmentation techniques are proposed. They are the binarization of the enhanced contrast data using the global threshold, and the segmentation using the modified watershed technique—local threshold by watershed. The proposed techniques were compared with a conventional marker-based watershed on the test images simulating low-quality tomography data and on the neutron tomography data of the samples of magnesium potassium phosphate cement (MKP). The obtained results demonstrate the advantages of the proposed techniques over the conventional watershed-based approach.
31 March 2025 in Advances in Nuclear Science and Applications
The WWR-K reactor is a multipurpose research reactor located in Almaty, Kazakhstan. Originally commissioned in 1967, it has undergone several modifications, including seismic safety improvements and a transition to low-enriched fuel, which doubled the thermal neutron flux in the reactor core. Currently, the WWR-K reactor supports a wide range of experimental and applied research activities, including nuclear fuel and structural materials testing, neutron radiography and tomography, neutron reflectometry, and neutron activation analysis. This paper provides an overview of the key experimental facilities available at the WWR-K reactor, including the critical facility, gas-vacuum loop facility, neutron tomography and radiography facility, neutron reflectometry, neutron diffraction, and instrumental neutron activation analysis systems. Each facility is described in terms of its technical parameters, capabilities, and applications in nuclear research, material science, and industrial testing. The reactor’s unique combination of neutron sources and experimental setups enables advanced studies in nuclear physics, radiation materials science, and applied engineering.
1 January 2020 in Physics of Particles and Nuclei Letters
The processes occurring during hardening of special cement pastes for the construction of storage facilities or disposal of radioactive waste containing aluminum metal were studied by means of a neutron radiography method. High reactivity of aluminum causes rapid release of hydrogen-containing components from the entire volume of cement paste. The cement pastes with organic additives to suppress the process of hydrogen-contained gases formation during the hardening of the cement materials were studied. Time dependences of the neutron attenuation coefficients for these special cement materials were obtained. Based on the neutron radiography data, the kinetics of hardening of those special cement pastes is discussed.
The spatial arrangement, size distribution, and shape of internal pores in several archaeological ceramic vessels from the Akterek burial site at Zhambyl District of Almaty Region, Republic of Kazakhstan were studied using neutron tomography. The internal pores were segmented from the obtained neutron data and the porosity value for the ancient ceramic samples was calculated. Analysis of the structural tomography data showed that the ceramic materials contained a large number of relatively small pores, with an average diameter less than 1.5 mm, while some ceramic objects had larger pores or cavities exceeding 2 mm in diameter. In addition, there are differences in the morphological parameters of large and small pores. It was suggested that these large pores formed as a result of temperature changes during the firing of the pottery ceramics. The relative shifting of Raman peaks in the carbon group in amorphous carbon, as an indicator of the firing temperature of ceramic materials, confirms this assumption.
26 March 2025 in Herald of the Kazakh-British technical university
As the methods, instrumentation, and resolution of three-dimensional spatial analysis have improved over the past twenty years, it is now possible to image the internal microstructure of multiphase materials in detail in three dimensions. Three-dimensional X-ray microtomography offers a unique opportunity for high spatial resolution imaging that can be achieved in compact desktop systems using X-ray microfocus sources. Recently, a modern desktop cone-beam X-ray microtomography system for quantitative analysis of materials in three dimensions was installed at the Institute of Nuclear Physics of the Ministry of Energy of the Republic of Kazakhstan. This paper presents the design, description of the main components, and technical parameters of this X-ray microtomography system, called IMAX. This system is designed to acquire, process, store X-ray images, and reconstruct three-dimensional data from angular projections for the study of internal structures and non-destructive testing of materials. The system consists of a microfocus X-ray source providing an X-ray energy range from 35 to 80 keV, a flat panel scintillation detector system allowing high-resolution digital imaging, optomechanical platforms for sample positioning, and radiation shielding. The first results of test measurements using this X-ray system are presented.