Jian Guo

Mr. Jian Guo

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2024 in Buildings
Verified
Journal Article
Open access
PDF file
PDPeng Deng
Peng Deng
YCYunkai Chen
Yunkai Chen
ZZZhongyi Zhu
Zhongyi Zhu
YLYan Liu
Yan Liu
SZShiqi Zhao
Shiqi Zhao
JGJian Guo
Jian Guo
In this study, 90 finite-element models are used to explore the behaviour of fibre-reinforced polymer (FRP) reinforced joints under combined in-plane bending (IPB) and axial load (AX). The effects of joint geometry, FRP layer count, and AX levels of the chord or brace are considered. Three typical failure modes are observed: chord plastic failure, brace plastic failure, and brace buckling failure. Increasing the number of FRP layers can ensure that failure is chord-related failure in a ductility manner rather than the unexpectedly brace-related brittle failure. Depending on the stress distribution of fibres, FRP reinforcement can restrict the deformation of joints subjected to complex loading patterns. Moreover, added FRP layers efficiently reduce the effect of brace AX on the IPB resistance. Finally, a modified strength equation is established, including the influence of FRP reinforcement, chord AX, and brace AX.

19 February 2025 in Materials
Verified
Journal Article
Open access
PDF file
PDPeng Deng
Peng Deng
XWXuening Wang
Xuening Wang
JGJian Guo
Jian Guo
YLYan Liu
Yan Liu
QZQi Zheng
Qi Zheng
The experiments were divided into two groups to establish a drying shrinkage model suitable for modified ceramsite geopolymer concrete (MCGC). In the first experimental group, via comparison with dry ceramsite (untreated), a method for modifying the ceramsite surface with a 6% silicone resin was proposed which could reduce its water absorption, enhance the compressive strength and slump of the corresponding concrete, and decrease the drying shrinkage. The second group systematically explored the influences of control factors on MCGC prepared from modified ceramsite. Different water/binder (w/b) ratios, [Na2O]/b ratios, and metakaolin content (MK/b) ratios were used in the experiment. Compressive strength and drying shrinkage tests were performed for 90 d. High w/b and Na2O/b ratios could enhance drying shrinkage. Moreover, 8% Na2O/b enhanced the compressive strength. Low compressive strength was obtained using 10% Na2O/b. A high MK/b ratio reduced drying shrinkage. However, high w/b and MK/b ratios hindered strength development. Finally, a model predicting drying shrinkage for MCGC with a high prediction accuracy was proposed by considering three control factors. Due to the variety of ceramsite pretreatment methods and the considered factor limitations, the model had potential for additional enhancements.

1 September 2025 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
PDPeng Deng
Peng Deng
XWXuening Wang
Xuening Wang
JGJian Guo
Jian Guo
ZZZhongyi Zhu
Zhongyi Zhu
YLYan Liu
Yan Liu
YAYishi An
Yishi An

29 December 2023 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
PDPeng Deng
Peng Deng
JGJian Guo
Jian Guo
ZZZhongyi Zhu
Zhongyi Zhu
YLYan Liu
Yan Liu
QZQiang Zhu
Qiang Zhu
A finite element (FE) analysis of corroded circular hollow section T-joints repaired using grouted clamps is presented in this study. To ensure an accurate simulation, experiments on a T-joint with uniform corrosion and an intact T-joint with grouted clamp are reproduced separately using an FE model. The experimental and FE modeling results correlate closely, displaying similar failure behaviors and loaddisplacement responses. Subsequently, a total of 56 FE T-joint models with varying degrees of corrosion on the chord, repaired by grouted clamp, were then analyzed numerically. The corrosion was artificially applied to the chords outer surface at depths of 10, 20, and 30 of the chords thickness. The models also account for variations in joint geometry, dictated by parameters β and γ, which range from 0.565 to 0.678 and from 21 to 28, respectively. Furthermore, grouted clamps properties were examined, including sleeve length, thickness, strength, as well as the thickness and strength of the grout, in relation to the complexity of the repair. The grouted clamp demonstrated significant repair capability, increasing the ultimate strength of the corroded joint by up to 2.23 times. Reinforcements that are both thicker and longer substantially enhance the joints ultimate strength. However, inappropriate repair construction results in an abrupt termination of the loaddisplacement curve and a brittle failure phenomenon outside reinforced chord region. Additional weight from the grouted clamp requires reasonable control, and sleeve overlapping ratio should be guaranteed to be greater than 0.7. The joint bearing capacity can be efficiently increased by thicker grouts and sleeves only in ductile failure cases. The confinement effect and mechanism of the grouted clamp in joint deformation were visually analyzed as stress distribution from FE analysis results. Finally, a prediction equation is proposed to estimate the static strength of the repaired joint through regression analysis.

13 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PDPeng Deng
Peng Deng
XZXianglong Zhang
Xianglong Zhang
WBWeiting Bai
Weiting Bai
JGJian Guo
Jian Guo
DCDongsong Chang
Dongsong Chang
Non-sintered lightweight aggregate (NSLA) produced by pelletizing and autoclaved curing has received widespread attention due to its environmental protection. However, the effect law of its characteristics, such as particle gradation and water absorption, on the performance of concrete still lacks clear understanding. In this study, seven different gradation types of concrete were designed to investigate the influence of the particle gradation (particularly particle size) of NSLA on the mechanical properties, especially the axial compressive performance, of alkali-activated slag non-sintered lightweight aggregate concrete (AN-LAC). Meanwhile, the different pre-treatment methods for NSLA were also studied to reduce the drying shrinkage of AN-LAC caused by the high water absorption of NSLA. The results showed that the compressive strength, splitting tensile strength, and flexural strength of AN-LAC at 3 d, 7 d, and 28 d showed an increasing trend when the average particle size decreased. The compressive strength of AN-LAC containing 3~5 and 6~10 mm NSLA at 28 days reached the maximum value of 56.7 MPa. AN-LAC containing NSLA with a small particle size exhibited improved elastic modulus. And the modified elastic modulus prediction model of AN-LAC was established considering the effect of particle size of NSLA. The NSLA, which was modified by using a silicone hydrophobic agent and pre-wetted by soaking in water, respectively, could enhance the strength of AN-LAC at 28 days. Combined with the analysis of the microscopic morphology of the ITZ, the shrinkage rate of the concrete with pre-wetted NSLA and modified NSLA at 90 days decreased by 17.7% and 10.3%, respectively.