Katja Uhrhan

Ms. Katja Uhrhan

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
KUKatja Uhrhan
Katja Uhrhan
ESEsther Marie Annie Nicole Schwindt
Esther Marie Annie Nicole Schwindt
Hartmut F. WitteHartmut F. Witte
Hartmut F. Witte
Electromyostimulation (EMS) is an up-and-coming training method that demands further fundamental research regarding its safety and efficacy. To investigate the influence of different stimulation parameters, electrode positions and electrode sizes on the resulting voltage in the tissue, a tissue mimicking phantom is needed. Therefore, this study describes the fabrication of a hydrogel arm phantom for EMS applications with the tissue layers of skin, fat, blood and muscle. The phantom was dielectrically validated in the frequency range of 20 Hz to 100 Hz. We also conducted electromyography (EMG) recordings during EMS on the phantom and compared them with the same measurements on a human arm. The phantom reproduces the dielectric properties of the tissues with deviations ranging from 0.8% to more than 100%. Although we found it difficult to find a compromise between mimicking the permittivity and electrical conductivity at the same time, the EMS–EMG measurements showed similar waveforms (1.9–9.5% deviation) in the phantom and human. Our research contributes to the field of dielectric tissue phantoms, as it proposes a multilayer arm phantom for EMS applications. Consequently, the phantom can be used for initial EMS investigations, but future research should focus on further improving the dielectric properties.

3 November 2025 in BMC Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MJMax Jäger
Max Jäger
KUKatja Uhrhan
Katja Uhrhan
CMChristine Mucha
Christine Mucha
MAMaría Alejandra Guzmán Alfaro
María Alejandra Guzmán Alfaro
HWHartmut Witte
Hartmut Witte
The mechanical properties of tumor tissue differ from those of healthy tissue. Therefore, surgeons palpate accessible surgical sites to determine tumor boundaries prior to resection. However, palpation is not possible during minimally invasive surgery, so instrumented palpation is required instead. This study investigates the suitability of an engineering method that combines mechanical object scanning and indentation to determine Young’s modulus of soft, tissue-like materials. To establish a defined reference, we tested our concept on silicone phantoms containing stiff tumor-like inclusions. We used a sensor consisting of a load cell connected to a rigid probe with a spherical indenter tip. Young’s modulus was calculated by measured force, indentation depth, and indenter geometry. These results were compared with those of a palpation experiment on the same specimens, conducted with surgeons. Validation results reflect the accuracy of the method. Error in estimation of Young’s modulus is: soft material 6.7%, stiff material 44.9%. Repeatability is high, with a standard deviation < 7%. By scanning a phantom and creating a stiffness image, we were able to identify the location and shape of the inclusion more clearly than experienced surgeons could using manual palpation. Looking ahead, the prospect of miniaturizing the presented technique for localizing tumor boundaries during surgery seems promising.

1 December 2023
Verified
Conference Paper
Closed access
KUKatja Uhrhan
Katja Uhrhan
MJMax Jäger
Max Jäger
HWHartmut Witte
Hartmut Witte