Systemic chemotherapy can result in considerable reduction of the size of colorectal liver metastases (CRLMs) to the point where they sometimes decrease even below the resolution of imaging modalities. These ‘vanishing lesions’ are observed in approximately 20% of patients, even with state-of-the-art imaging1. Nonetheless, microscopic residual disease is frequently present2,3 and tumour regrowth occurs in approximately one-third after ‘watch and wait’1. The current recommendation is to resect or ablate all original disease sites whenever feasible4. However, intraoperative localization of vanishing lesions is challenging5,6. Surgical navigation provides a live, virtual representation of the surgical scene, using a three-dimensional (3D) model of the organ that includes tumours and critical structures. The model is generated by delineating preoperative diagnostic imaging. When an accurate registration (that is, preoperative alignment of the patient’s liver and 3D model) is achieved, surgical navigation can help to localize vanished lesions7,8. In previous work, the advantages of ultrasonography-based navigation in open liver surgery combined with electromagnetic (EM) liver tracking were presented9. This approach resulted in a registration accuracy of 8.5 ± 4.2 mm while compensating for liver movement. In this study, the advantages of this method were applied for localization and treatment of vanished CRLMs.
1 July 2025 in International Journal of Computer Assisted Radiology and Surgery
Purpose: Understanding patient-specific liver anatomy is crucial for patient safety and achieving complete treatment of all tumors during surgery. This study evaluates the impact of the use of patient-specific 3D liver models and surgical navigation on procedural complexity in open liver surgery. Methods: Patients with colorectal liver metastases scheduled for open liver surgery were included between June 2022 and October 2023 at the Netherlands Cancer Institute. Patient-specific 3D liver models could be used upon request during the surgical procedure. Subsequently, surgeons could request additional surgical navigation by landmark registration using an electromagnetically tracked ultrasound transducer. Postoperatively, surgeons assessed the impact of the use of the model and navigation on procedural complexity on a scale from 1 to 10. Results: 35 patients were included in this study, with a median number of 8 (ranging from 3 to 25) tumors. 3D models were utilized in all procedures. Additional navigation was requested in 21/35 of patients to improve intraoperative planning and tumor localization. The mean procedural complexity score with navigation was 4.3 (95% CI [3.7, 5.0]), compared to 7.8 (95% CI [6.6, 9.0]) with the 3D model alone. Both visualization methods improved lesion localization and provided better anatomical insight. Conclusion: 3D models and surgical navigation significantly reduce the complexity of open liver surgery, especially in patients with bilobar disease. These tools enhance intraoperative decision-making and may lead to better surgical outcomes. The stepwise implementation of the visualization techniques in this study underscores the added benefit of surgical navigation beyond 3D modeling alone, supporting its potential for broader clinical implementation.
PurposeTraining and evaluation of the performance of a supervised deep-learning model for the segmentation of hepatic tumors from intraoperative US (iUS) images, with the purpose of improving the accuracy of tumor margin assessment during liver surgeries and the detection of lesions during colorectal surgeries.ApproachIn this retrospective study, a U-Net network was trained with the nnU-Net framework in different configurations for the segmentation of CRLM from iUS. The model was trained on B-mode intraoperative hepatic US images, hand-labeled by an expert clinician. The model was tested on an independent set of similar images. The average age of the study population was 61.9 ± 9.9 years. Ground truth for the test set was provided by a radiologist, and three extra delineation sets were used for the computation of inter-observer variability.ResultsThe presented model achieved a DSC of 0.84 (p=0.0037), which is comparable to the expert human raters scores. The model segmented hypoechoic and mixed lesions more accurately (DSC of 0.89 and 0.88, respectively) than hyper- and isoechoic ones (DSC of 0.70 and 0.60, respectively) only missing isoechoic or >20 mm in diameter (8% of the tumors) lesions. The inclusion of extra margins of probable tumor tissue around the lesions in the training ground truth resulted in lower DSCs of 0.75 (p=0.0022).ConclusionThe model can accurately segment hepatic tumors from iUS images and has the potential to speed up the resection margin definition during surgeries and the detection of lesion in screenings by automating iUS assessment.
23 February 2026 in International Journal of Computer Assisted Radiology and Surgery
Purpose: This proof-of-concept study evaluates the feasibility and accuracy of an ultrasound-based navigation system for open liver surgery. Unlike most conventional systems that rely on registration to preoperative imaging, the proposed system provides navigation-guided resection using 3D models generated from intraoperative ultrasound. Methods: A pilot study was conducted in 25 patients undergoing resection of liver metastases. The first 5 cases served to optimize the workflow. Intraoperatively, an electromagnetic sensor compensated for organ motion, after which an ultrasound volume was acquired. Vasculature was segmented automatically and tumors semi-automatically using region-growing ( n = 15) or a deep learning algorithm ( n = 5). The resulting 3D model was visualized alongside tracked surgical instruments. Accuracy was assessed by comparing the distance between surgical clips and tumors in the navigation software with the same distance on a postoperative CT of the resected specimen. Results: Navigation was successfully established in all 20 patients. However, 4 cases were excluded from the accuracy assessment due to intraoperative sensor detachment ( n = 3) or incorrect data recording ( n = 1). The complete navigation workflow was operational within 5–10 min. In 16 evaluable patients, 78 clip-to-tumor distances were analyzed. The median navigation accuracy was 3.2 mm [IQR: 2.8–4.8 mm], and an R 0 resection was achieved in 15/16 (93.8%) patients, and one patient had an R 1 vascular resection. Conclusion: Navigation based solely on intraoperative ultrasound is feasible and accurate for liver surgery. This approach paves the way for simpler and more accurate image guidance systems.
Non-rigid registration is essential for augmented reality-guided laparoscopic liver surgery, as it enables the fusion of preoperative information such as tumor location and vascular structures into the limited intraoperative view, thereby enhancing surgical navigation. A prerequisite is the accurate prediction of intraoperative liver deformation, which remains highly challenging due to factors such as large deformation caused by pneumoperitoneum, respiration and tool interaction as well as noisy intraoperative data, and limited field of view due to occlusion and constrained camera movement. To address these challenges, we introduce PIVOTS, a Preoperative to Intraoperative VOlume-To-Surface registration neural network that directly takes point clouds as input for deformation prediction. The geometric feature extraction encoder allows multi-resolution feature extraction, and the decoder, comprising inter-modality cross attention modules, enables information exchange between pre- and intraoperative features and accurate multi-level displacement prediction. We train the neural network on a large synthetic dataset created using a biomechanical simulation pipeline that explicitly targets the mentioned intraoperative challenges and validate its performance on both synthetic and real datasets. Results demonstrate superior registration performance of our method compared to baseline methods, exhibiting strong robustness against high amounts of noise, large deformation, and various levels of intraoperative visibility. The network is fast enough to run multiple times per second and directly generalizes to new patients without retraining. We publish training and test sets as evaluation benchmarks in an effort to contribute to the development of more robust liver registration methods based on volume-to-surface data. Code, docker container and datasets are available athttps://github.com/pengliu-nct/PIVOTS.
Background: The aim of this study was to develop and evaluate a deep learning-based automated segmentation method for hepatic anatomy (i.e., parenchyma, tumors, portal vein, hepatic vein and biliary tree) from the hepatobiliary phase of gadoxetic acid-enhanced MRI. This method should ease the clinical workflow of preoperative planning. Methods: Manual segmentation was performed on hepatobiliary phase MRI scans from 90 consecutive patients who underwent liver surgery between January 2020 and October 2023. A deep learning network (nnU-Net v1) was trained on 72 patients with an extra focus on thin structures and topography preservation. Performance was evaluated on an 18-patient test set by comparing automated and manual segmentations using Dice similarity coefficient (DSC). Following clinical integration, 10 segmentations (assessment dataset) were generated using the network and manually refined for clinical use to quantify required adjustments using DSC. Results: In the test set, DSCs were 0.97+/-0.01 for liver parenchyma, 0.80+/-0.04 for hepatic vein, 0.79+/-0.07 for biliary tree, 0.77+/-0.17 for tumors, and 0.74+/-0.06 for portal vein. Average tumor detection rate was 76.6+/-24.1%, with a median of one false-positive per patient. The assessment dataset showed minor adjustments were required for clinical use of the 3D models, with high DSCs for parenchyma (1.00+/-0.00), portal vein (0.98+/-0.01) and hepatic vein (0.95+/-0.07). Tumor segmentation exhibited greater variability (DSC 0.80+/-0.27). During prospective clinical use, the model detected three additional tumors initially missed by radiologists. Conclusions: The proposed nnU-Net-based segmentation method enables accurate and automated delineation of hepatic anatomy. This enables 3D planning to be applied efficiently as a standard-of-care for every patient undergoing liver surgery.