Michael Hannigan

Dr. Michael Hannigan


Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2013 in Environmental Science & Technology
Verified
Journal Article
Closed access
RBRobert M. Bowers
Robert M. Bowers
NCNicholas Clements
Nicholas Clements
JEJoanne B. Emerson
Joanne B. Emerson
CWChristine Wiedinmyer
Christine Wiedinmyer
Michael HanniganMichael Hannigan
Michael Hannigan
NFNoah Fierer
Noah Fierer

4 March 2009 in Environmental Science & Technology
Verified
Journal Article
Closed access
CMClaudia Mohr
Claudia Mohr
JHJ. Alex Huffman
J. Alex Huffman
MCMichael J. Cubison
Michael J. Cubison
Allison C. AikenAllison C. Aiken
Allison C. Aiken
KDKenneth S. Docherty
Kenneth S. Docherty
JJJose L. Jimenez
Jose L. Jimenez

7 October 2014 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
RPR. Piedrahita
R. Piedrahita
YXY. Xiang
Y. Xiang
NMN. Masson
N. Masson
JOJ. Ortega
J. Ortega
ACA. Collier
A. Collier
LSL. Shang
L. Shang
Advances in embedded systems and low-cost gas sensors are enabling a new wave of low-cost air quality monitoring tools. Our team has been engaged in the development of low-cost, wearable, air quality monitors (M-Pods) using the Arduino platform. These M-Pods house two types of sensors – commercially available metal oxide semiconductor (MOx) sensors used to measure CO, O3, NO2, and total VOCs, and NDIR sensors used to measure CO2. The MOx sensors are low in cost and show high sensitivity near ambient levels; however they display non-linear output signals and have cross-sensitivity effects. Thus, a quantification system was developed to convert the MOx sensor signals into concentrations. We conducted two types of validation studies – first, deployments at a regulatory monitoring station in Denver, Colorado, and second, a user study. In the two deployments (at the regulatory monitoring station), M-Pod concentrations were determined using collocation calibrations and laboratory calibration techniques. M-Pods were placed near regulatory monitors to derive calibration function coefficients using the regulatory monitors as the standard. The form of the calibration function was derived based on laboratory experiments. We discuss various techniques used to estimate measurement uncertainties. The deployments revealed that collocation calibrations provide more accurate concentration estimates than laboratory calibrations. During collocation calibrations, median standard errors ranged between 4.0–6.1 ppb for O3, 6.4–8.4 ppb for NO2, 0.28–0.44 ppm for CO, and 16.8 ppm for CO2. Median signal to noise (S / N) ratios for the M-Pod sensors were higher than the regulatory instruments: for NO2, 3.6 compared to 23.4; for O3, 1.4 compared to 1.6; for CO, 1.1 compared to 10.0; and for CO2, 42.2 compared to 300–500. By contrast, lab calibrations added bias and made it difficult to cover the necessary range of environmental conditions to obtain a good calibration. A separate user study was also conducted to assess uncertainty estimates and sensor variability. In this study, 9 M-Pods were calibrated via collocation multiple times over 4 weeks, and sensor drift was analyzed, with the result being a calibration function that included baseline drift. Three pairs of M-Pods were deployed, while users individually carried the other three. The user study suggested that inter-M-Pod variability between paired units was on the same order as calibration uncertainty; however, it is difficult to make conclusions about the actual personal exposure levels due to the level of user engagement. The user study provided real-world sensor drift data, showing limited CO drift (under −0.05 ppm day−1), and higher for O3 (−2.6 to 2.0 ppb day−1), NO2 (−1.56 to 0.51 ppb day−1), and CO2 (−4.2 to 3.1 ppm day−1). Overall, the user study confirmed the utility of the M-Pod as a low-cost tool to assess personal exposure.

28 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Andrea ClementsAndrea Clements
Andrea Clements
WGWilliam G. Griswold
William G. Griswold
ARAbhijit Rs
Abhijit Rs
JJJill Johnston
Jill Johnston
MHMegan M. Herting
Megan M. Herting
Michael HanniganMichael Hannigan
Michael Hannigan
In May 2017, a two-day workshop was held in Los Angeles (California, U.S.A.) to gather practitioners who work with low-cost sensors used to make air quality measurements. The community of practice included individuals from academia, industry, non-profit groups, community-based organizations, and regulatory agencies. The group gathered to share knowledge developed from a variety of pilot projects in hopes of advancing the collective knowledge about how best to use low-cost air quality sensors. Panel discussion topics included: (1) best practices for deployment and calibration of low-cost sensor systems, (2) data standardization efforts and database design, (3) advances in sensor calibration, data management, and data analysis and visualization, and (4) lessons learned from research/community partnerships to encourage purposeful use of sensors and create change/action. Panel discussions summarized knowledge advances and project successes while also highlighting the questions, unresolved issues, and technological limitations that still remain within the low-cost air quality sensor arena.

1 August 2012 in Environmental Health Perspectives
Verified
Journal Article
Open access
Sun-Young KimSun-Young Kim
Sun-Young Kim
JPJennifer L Peel
Jennifer L Peel
Michael HanniganMichael Hannigan
Michael Hannigan
SDSteven J Dutton
Steven J Dutton
LSLianne Sheppard
Lianne Sheppard
SVSverre Vedal
Sverre Vedal
A peer-reviewed open access journal published by the National Institute of Environmental Health Sciences

4 September 2008 in Environmental Science & Technology
Verified
Journal Article
Closed access
YZYuanxun Zhang
Yuanxun Zhang
JSJames J. Schauer
James J. Schauer
MSMartin M. Shafer
Martin M. Shafer
Michael HanniganMichael Hannigan
Michael Hannigan
SDSteven J. Dutton
Steven J. Dutton