Tarvinder Dhanjal

Prof. Tarvinder Dhanjal

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
MGMaxime Guenoun
Maxime Guenoun
SCSerge Cohen
Serge Cohen
MVMarc Villaceque
Marc Villaceque
ASAli Sharareh
Ali Sharareh
JSJerome Schwartz
Jerome Schwartz
NLNicolas Lellouche
Nicolas Lellouche
Since the introduction of direct oral anticoagulant (DOAC) for atrial fibrillation (AF) therapy, inappropriate and/or underdosing of these drugs has been a major clinical challenge. We evaluated the characteristics of patients with AF treated with inappropriate and low-dose DOACs. Patients with AF treated with inappropriate and low-dose DOACs from October 2021 to December 2021 were evaluated from the French National Prospective Registry (PAFF). We evaluated 1890 patients with AF receiving DOACs (apixaban 55%, dabigatran 7%, and rivaroxaban 38%). Inappropriate dosing was noted in 18% of the population. Patients with appropriate dosing had less comorbidities: younger age (75 ± 10 vs. 82 ± 8 years old, P < 0.0001), reduced chronic renal failure (26 vs. 61%, P < 0.0001), and lower CHA2DS2VASc and HASBLED scores (3 ± 2 vs. 4 ± 3, P < 0.0001; 2 ±1 vs. 2 ± 2, P < 0.0001), respectively. In multivariate analysis, older age (P < 0.0001) and a higher CHA2DS2VASc score (P = 0.0056) were independently associated with inappropriate DOAC dosing. Among 472 patients (27%) treated with low-dose rivaroxaban or apixaban, 46% were inappropriately underdosed. Patients inappropriately underdosed were younger (82.3 ± 8.4 vs. 85.9 ± 5.9 years, P < 0.0001) with less chronic renal disease (47 vs. 98%, P < 0.0001). However, these patients had higher rates of prior haemorrhagic events (18 vs. 10%, P = 0.01), clopidogrel use (11 vs. 3%, P = 0.0002), and apixaban prescription (74 vs. 50%, P < 0.0001). Within this large registry, DOACs were associated with inappropriate dosing in 18% of cases. Independent predictors of inappropriate dosing were high CHA2DS2VASc scores and older age. Moreover, 46% of patients treated with low-dose DOACs were inappropriately underdosed and more frequently in patients treated with apixaban.

4 January 2021 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Open access
PDF file
Riccardo ProiettiRiccardo Proietti
Riccardo Proietti
RDRory Dowd
Rory Dowd
LGLim Ven Gee
Lim Ven Gee
SYShamil Yusuf
Shamil Yusuf
SPSandeep Panikker
Sandeep Panikker
TDTarvinder Dhanjal
Tarvinder Dhanjal
Background: Substrate mapping has highlighted the importance of targeting diastolic conduction channels and late potentials during ventricular tachycardia (VT) ablation. State-of-the-art multipolar mapping catheters have enhanced mapping capabilities. The purpose of this study was to investigate whether long-term outcomes were improved with the use of a HD Grid mapping catheter combining complementary mapping strategies in patients with structural heart disease VT.Methods: Consecutive patients underwent VT ablation assigned to either HD Grid, Pentaray, Duodeca, or point-by-point (PbyP) RF mapping catheters. Clinical endpoints included recurrent anti-tachycardia pacing (ATP), appropriate shock, asymptomatic non-sustained VT, or all-cause death.Results: Seventy-three procedures were performed (33 HD Grid, 22 Pentaray, 12 Duodeca, and 6 PbyP) with no significant difference in baseline characteristics. Substrate mapping was performed in 97% of cases. Activation maps were generated in 82% of HD Grid cases (Pentaray 64%; Duodeca 92%; PbyP 33% (p = 0.025)) with similar trends in entrainment and pace mapping. Elimination of all VTs occurred in 79% of HD Grid cases (Pentaray 55%; Duodeca 83%; PbyP 33% (p = 0.04)). With a mean follow-up of 372 ± 234 days, freedom from recurrent ATP and shock was 97% and 100% respectively in the HD Grid group (Pentaray 64%, 82%; Duodeca 58%, 83%; PbyP 33%, 33% (log rankp = 0.0042,p = 0.0002)).Conclusions: This study highlights a step-wise improvement in survival free from ICD therapies as the density of mapping capability increases. By using a high-density mapping catheter and combining complementary mapping strategies in a strict procedural workflow, long-term clinical outcomes are improved.

29 September 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
JMJoseph Mayer
Joseph Mayer
JAJaffar Al-Sheikhli
Jaffar Al-Sheikhli
MNMaria Niespialowska-Steuden
Maria Niespialowska-Steuden
IPIan Patchett
Ian Patchett
JWJames Winter
James Winter
TDTarvinder Dhanjal
Tarvinder Dhanjal
Differentiating near-field (NF) and far-field (FF) electrograms (EGMs) is crucial in identifying critical arrhythmogenic substrate during ventricular tachycardia (VT) ablation. A novel algorithm annotates NF-fractionated signals enabling EGM peak frequency (PF) determination using wavelet transformation. This study evaluated the algorithms’ effectiveness in identifying critical components of the VT circuit during substrate mapping. A multicentre, international cohort undergoing VT ablation was investigated. VT activation maps were used to demarcate the isthmus zone (IZ). Offline analysis was performed to evaluate the diagnostic performance of low-voltage area (LVA) PF substrate mapping. A total of 30 patients encompassing 198 935 EGMs were included. The IZ PF was significantly higher in sinus rhythm (SR) compared to right ventricular paced (RVp) substrate maps (234 Hz (195–294) vs. 197 Hz (166–220); P = 0.010). Compared to LVA PF, the IZ PF was significantly higher in both SR and RVp substrate maps (area under curve, AUC: 0.74 and 0.70, respectively). The LVA PF threshold of ≥200 Hz was optimal in SR maps (sensitivity 69%; specificity 64%) and RVp maps (sensitivity 60%; specificity 64%) in identifying the VT isthmus. In amiodarone-treated patients (n = 20), the SR substrate map IZ PF was significantly lower (222 Hz (186–257) vs. 303 Hz (244–375), P = 0.009) compared to amiodarone-naïve patients (n = 10). The ≥200 Hz LVA PF threshold resulted in an 80% freedom from VT with a trend towards reduced ablation lesions and radiofrequency times. LVA PF substrate mapping identifies critical components of the VT circuit with an optimal threshold of ≥200 Hz. Isthmus PF is influenced by chronic amiodarone therapy with lower values observed during RV pacing.

9 October 2019 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Closed access
PDF file
Riccardo ProiettiRiccardo Proietti
Riccardo Proietti
AAAhmed Adlan
Ahmed Adlan
RDRory Dowd
Rory Dowd
SAShershah Assadullah
Shershah Assadullah
BABashar Aldhoon
Bashar Aldhoon
TDTarvinder Dhanjal
Tarvinder Dhanjal

28 December 2020 in Journal of Arrhythmia
Verified
Journal Article
Open access
PDF file
Riccardo ProiettiRiccardo Proietti
Riccardo Proietti
LLLuca Lichelli
Luca Lichelli
NLNicolas Lellouche
Nicolas Lellouche
TDTarvinder Dhanjal
Tarvinder Dhanjal
Radiofrequency catheter ablation has become an established treatment for ventricular tachycardia. The exponential increase in procedures has provided further insights into mechanisms causing arrhythmias and identification of ablation targets with the development of new mapping strategies. Since the definition of criteria to identify myocardial dense scar, borderzone and normal myocardium, and the description of isolated late potentials, local abnormal ventricular activity and decrementing evoked potential mapping, substrate‐guided ablation has progressively become the method of choice to guide procedures. Accordingly, a wide range of ablation strategies have been developed from scar homogenization to scar dechanneling or core isolation using increasingly complex and precise tools such as multipolar or omnipolar mapping catheters. Despite these advances long‐term success rates for VT ablation have remained static and lower in nonischemic than ischemic heart disease because of the more patchy distribution of myocardial scar. Ablation aims to deliver an irreversible loss of cellular excitability by myocardial heating to a temperatures exceeding 50°C. Many indicators of ablation efficacy have been developed such as contact force, impedance drop, force‐time integral and ablation index, mostly validated in atrial fibrillation ablation. In ventricular procedures there is limited data and ablation lesion parameters have been scarcely investigated. Since VT arrhythmia recurrence can be related to inadequate RF lesion formation, it seems reasonable to establish robust markers of ablation efficacy.

10 April 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
JAJaffar Al-Sheikhli
Jaffar Al-Sheikhli
JWJames Winter
James Winter
IRIvo Roca-Luque
Ivo Roca-Luque
PLPier D Lambiase
Pier D Lambiase
MOMichele Orini
Michele Orini
TDTarvinder Dhanjal
Tarvinder Dhanjal
Ventricular tachycardia (VT) ablation approaches based on high-density mapping, which enable the rapid acquisition of thousands of mapping points in order to delineate slow conduction zones, have been widely adopted.1 The identification of functionally relevant substrates has been advanced by the identification of potentials participating in the initiation and/or maintenance of scar-dependent VT. During right ventricular apical (RVA) pacing with an extra-stimulus (S2), these potentials display delayed conduction (decremental) behaviour (DeEP).2 This methodology has been shown to be more specific in identifying the critical isthmus of re-entrant VT.3 An important factor accounting for decrement is conduction velocity (CV) restitution.2 With a short-coupled S2, CV will decrease, and further delay occurs in the near-field signal with respect to the far-field signal, creating DeEPs. Conventionally, the S2 has been delivered at ventricular effective refractory period (VERP) + 20 ms to elicit decrement.3–5 However data are lacking on justifying the delivery of the S2 at VERP + 20 ms, which may result in areas defined as DeEP due to intrinsic CV restitution properties, thus creating larger-than-required ablation target areas. We hypothesized that DeEPs are better identified with longer S2 coupling intervals. The second hypothesis was to consider the definition of a DeEP as the range of decrement beyond 10 ms has not been previously explored and to identify the best combination of these parameters.