Norma Cecilia Cavazos-Rocha

Dr. Norma Cecilia Cavazos-Rocha

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2024 in Nutrients
Verified
Journal Article
Open access
PDF file
ATAlexandra Tijerina
Alexandra Tijerina
AGAurora de Jesús Garza
Aurora de Jesús Garza
ALAbad Arturo Lopez-Hernandez
Abad Arturo Lopez-Hernandez
NCNorma Cecilia Cavazos-Rocha
Norma Cecilia Cavazos-Rocha
ARAna Romo
Ana Romo
SGSalas Rogelio García
Salas Rogelio García
The aim of this study was to validate an HPLC-UV method to assess vitamin D status by determining the linearity and precision of the 25-hydroxyvitamin D3 (25(OH)D3) calibration curve, the limits of detection, quantitation and robustness of the method, and its accuracy. A second stock solution of 25(OH)D3 was prepared (500 ng/mL), and working dilutions (5, 10, 20, 30, 40, and 50 ng/mL) were prepared for a calibration curve. The HPLC equipment had a UV-Vis diode-array detector and utilized an AcclaimTM 120 C18 column (5 µm, 4.6 × 250 mm) with a flow rate of 1.2 mL/min, a column temperature of 30 °C, and the standards and samples were maintained at 4 °C, with an injection volume of 100 µL. Detection of 25(OH)D3 was determined at 265 nm, with a retention time of 4.0 min. The validation was conducted according to the FDA Validation of Analytical Procedures: Guidance for Industry. Vitamin D was extracted from plasma samples using acetonitrile (ACN)–0.1% formic acid (2:1 v/v), and the percentage of recovery was calculated. The proposed method conditions gave excellent linearity (R2 = 0.9989) and the linearity coefficient was R2 > 0.99 for 25(OH)D3. The detection and quantification limits were 1.1703 ng/mL and 3.5462 ng/mL, respectively. Decreasing or increasing the reading temperature by 1 °C decreased the response units (AU) of vitamin D, 25(OH)D3. When the current flow rate decreased by 0.2 mL/min (1.0 mL/min), the retention time increased to 4.913 min, whereas an increase of 0.2 mL/min of the proposed flow rate (1.4 mL/min) decreased the retention time to 3.500 min. The percentage of recovery varied from 92.2% to 97.1%. The proposed method to quantify a vitamin D metabolite (25(OH)D3) in human plasma samples was reliable and validated.

20 March 2025 in Acta Chimica Slovenica
Verified
Journal Article
Open access
PDF file
OPOmar J. Portillo-Castillo
Omar J. Portillo-Castillo
PCPaola Cobos-Cervantes
Paola Cobos-Cervantes
NCNorma Cecilia Cavazos-Rocha
Norma Cecilia Cavazos-Rocha
RARocío Alvarez-Román
Rocío Alvarez-Román
LPLuis Alejandro Pérez-López
Luis Alejandro Pérez-López
GGGraciela Granados-Guzmán
Graciela Granados-Guzmán
In this study, a simple, and eco-friendly high-performance liquid chromatography-diode array detection (HPLC-DAD) method was developed and validated for analyzing methylxanthines, including theobromine (TB), theophylline (TF), and caffeine (CF). This method demonstrated excellent performance using an isocratic mobile phase of water (85%) and ethanol (15%) at 0.1 mL min–1, 25 °C in a core–shell Kinetex® C18 column. The method was linear (1–100 μg mL–1), exhibiting high precision and accuracy with relative standard deviations below 2.67% and recoveries ranging from 98.15% to 108.88%. The detection and quantification limits ranged from 0.19–0.26 μg mL–1 and 0.64–0.87 μg mL–1, respectively. We applied this method to analyze powdered lemon-flavored beverages enriched with black or green tea extracts. CF was detected exceeding 1.62 g kg–1. The proposed method showed excellent greenness, evidenced by the Analytical Eco-Scale, Analytical GREEnness metric (AGREE) calculator, and GAPI.