Zexiao Li

Dr. Zexiao Li


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ZZZhen Zeng
Zhen Zeng
Zexiao LiZexiao Li
Zexiao Li
FFFengzhou Fang
Fengzhou Fang
XZXiaodong Zhang
Xiaodong Zhang
Phase compensation is a critical step for the optical measuring system using spatial light modulator (SLM). The wavefront distortion from SLM is mainly caused by the phase modulation non-linearity and non-uniformity of SLM’s physical structure and environmental conditions. A phase modulation characteristic calibration and compensation method for liquid crystal on silicon spatial light modulator (LCoS-SLM) with a Twyman-Green interferometer is illustrated in this study. A method using two sequences of phase maps is proposed to calibrate the non-uniformity character over the whole aperture of LCoS-SLM at pixel level. A phase compensation matrix is calculated to correct the actual phase modulation of the LCoS-SLM and ensure that the designed wavefront could be achieved. Compared with previously known compensation methods, the proposed method could obtain the phase modulation characteristic curve of each pixel on the LCoS-SLM, rather than a mono look-up table (LUT) curve or multi-LUT curves corresponding to an array of blocks over the whole aperture of the LCoS-SLM. The experiment results show that the phase compensation precision could reach a peak-valley value of 0.061λ in wavefront and this method can be applied in generating freeform wave front for precise optical performance.

17 March 2022 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ZMZhaoxun Mi
Zhaoxun Mi
Zexiao LiZexiao Li
Zexiao Li
XZXiaodong Zhang
Xiaodong Zhang
Off-axis reflective optical systems have been widely used due to the nature of miniaturization and no obscuration. However, it is difficult to control the desired system structure during the designation and optimization, especially to maintain the compact system structure. In this paper, a constructing method of off-axis reflective optical systems is proposed to achieve the compact feature. The structure construction combines the constraints of the aberration and the system structure. Multiple parameters of aberration (optical performance) and the mirror coordinates (system structure) are simultaneously optimized to obtain the initial structure using the genetic algorithm. The initial structure is compact, unobscured, and remains less difficult to optimize. A compact off-axis three-mirror reflective system was designed with an entrance pupil diameter of 90 mm, a focal length of 405 mm, and a field of view of 3 ∘ × 3 ∘ . Each mirror is expressed by an XY polynomial to achieve optimized optical performance.

18 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RHRan Hao
Ran Hao
LZLinlin Zhu
Linlin Zhu
Zexiao LiZexiao Li
Zexiao Li
FFFengzhou Fang
Fengzhou Fang
XZXiaodong Zhang
Xiaodong Zhang
Transparent films are significant industrial components that are widely used in modern optics, microelectronics, optical engineering, and other related fields. There is an urgent need for the fast and stable thickness measurement of industrial films at the micron-grade. This paper built a miniaturized and low-cost film thickness measurement system based on confocal spectral imaging and the principle of thin-film spectral interference. The reflection interference spectrum was analyzed to extract the phase term introduced by the film thickness from the full spectrum information, where local spectral noise can be better corrected. An efficient and robust film thickness calculation algorithm was realized without any calibrating sample. The micron-grade thickness measurement system had an industrial property with a measurement range of up to 75 μm with a measurement uncertainty of 0.1 μm, presenting a good performance in single-layer film thickness measurement with high efficiency.

13 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LZLinlin Zhu
Linlin Zhu
YDYuchu Dong
Yuchu Dong
Zexiao LiZexiao Li
Zexiao Li
XZXiaodong Zhang
Xiaodong Zhang
The two peaks characteristic of yellow and blue light in the spectrum of dual-wavelength white light emitting diodes (LEDs) introduce distinctive features to the interference signal of white light scanning interferometry (WLSI). The distinctive features are defined as discontinuities, so that the fringe contrast function cannot be modeled as a single Gaussian function, and causes the interferogram to have uneven distribution of fringes of different orders in the scanning interferometer. This phenomenon leads to the low accuracy of the zero-order fringe position in the envelope calculation, which affects the repeatability and accuracy of the interferometry. This paper proposes a new surface recovery algorithm based on the Hilbert phase envelope and adjacent reference points calculation, which can effectively overcome the influence of the discontinuous signal of dual-wavelength LED white light interference on the three-dimensional reconstruction of WLSI measurements. The reliability of the algorithm is verified by experiments, and the measurement accuracy of LED WLSI system is evaluated.

4 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RLRuoxin Liu
Ruoxin Liu
Zexiao LiZexiao Li
Zexiao Li
YDYiTing Duan
YiTing Duan
FFFengzhou Fang
Fengzhou Fang
Off-axis reflective optical systems find wide applications in various industries, but the related manufacturing issues have not been well considered in the design process. This paper proposed a design method for cylindrical reflective systems considering manufacturing constraints to facilitate ultra-precision raster milling. An appropriate index to evaluate manufacturing constraints is established. The optimization solution is implemented for the objective function composed of primary aberration coefficients with weights and constraint conditions of the structural configuration by introducing the genetic algorithm. The four-mirror initial structure with a good imaging quality and a special structural configuration is then obtained. The method’s feasibility is validated by designing an off-axis four-mirror afocal system with an entrance pupil diameter of 170 mm, a field of view of 3° × 3° and a compression ratio of five times. All mirrors in the system are designed to be distributed along a cylinder.

30 June 2025 in Photonics
Verified
Journal Article
Open access
PDF file
WCWeisheng Cheng
Weisheng Cheng
Zexiao LiZexiao Li
Zexiao Li
XWXuanzong Wu
Xuanzong Wu
SYShuangxiong Yin
Shuangxiong Yin
BZBo Zhang
Bo Zhang
XZXiaodong Zhang
Xiaodong Zhang
Silicon (Si) and silicon carbide (SiC) are second- and third-generation semiconductor materials with excellent properties that are particularly suitable for applications in scenarios such as high temperature, high voltage, and high frequency. Si/SiC wafers face warpage and bending problems during production, which can seriously affect subsequent processing. Fast, accurate, and comprehensive detection of thickness, thickness variation, and flatness (including bow and warpage) of SiC and Si wafers is an industry-recognized challenge. Frequency scanning interferometry (FSI) can synchronize the upper and lower surfaces and thickness information of transparent parallel thin wafers, but it is still affected by multiple interfacial harmonic reflections, reflectivity asymmetry, and phase modulation uncertainty when measuring SiC thin wafers, which leads to thickness calculation errors and face reconstruction deviations. To this end, this paper proposes a high-precision facet reconstruction method for SiC/Si structures, which combines harmonic spectral domain decomposition, refractive index gradient constraints, and partitioning optimization strategy, and introduces interferometric signal “oversampling” and weighted fusion of multiple sets of data to effectively suppress higher-order harmonic interferences, and to enhance the accuracy of phase resolution. The multi-layer iterative optimization model further enhances the measurement accuracy and robustness of the system. The flatness measurement system constructed based on this method can realize the simultaneous acquisition of three-dimensional top and bottom surfaces on 6-inch Si/SiC wafers, and accurately reconstruct the key parameters, such as flatness, warpage, and thickness variation (TTV). A comparison with the Corning Tropel FlatMaster commercial system shows that this method has high consistency and good applicability.