Silicon (Si) and silicon carbide (SiC) are second- and third-generation semiconductor materials with excellent properties that are particularly suitable for applications in scenarios such as high temperature, high voltage, and high frequency. Si/SiC wafers face warpage and bending problems during production, which can seriously affect subsequent processing. Fast, accurate, and comprehensive detection of thickness, thickness variation, and flatness (including bow and warpage) of SiC and Si wafers is an industry-recognized challenge. Frequency scanning interferometry (FSI) can synchronize the upper and lower surfaces and thickness information of transparent parallel thin wafers, but it is still affected by multiple interfacial harmonic reflections, reflectivity asymmetry, and phase modulation uncertainty when measuring SiC thin wafers, which leads to thickness calculation errors and face reconstruction deviations. To this end, this paper proposes a high-precision facet reconstruction method for SiC/Si structures, which combines harmonic spectral domain decomposition, refractive index gradient constraints, and partitioning optimization strategy, and introduces interferometric signal “oversampling” and weighted fusion of multiple sets of data to effectively suppress higher-order harmonic interferences, and to enhance the accuracy of phase resolution. The multi-layer iterative optimization model further enhances the measurement accuracy and robustness of the system. The flatness measurement system constructed based on this method can realize the simultaneous acquisition of three-dimensional top and bottom surfaces on 6-inch Si/SiC wafers, and accurately reconstruct the key parameters, such as flatness, warpage, and thickness variation (TTV). A comparison with the Corning Tropel FlatMaster commercial system shows that this method has high consistency and good applicability.
To counteract accuracy degradation in micrometer-scale precision marking—where the precision marking (PM) system denotes the precision marking platform and the Optical Microscope (OM) system denotes the camera-based visual guidance module—a genetic-algorithm-based framework for motion-system calibration and error control is introduced. A kinematic error model is established to capture multi-source coupled errors in the PM system, and the propagation mechanisms of axis misalignment, pose misregistration, and flatness-induced errors are analyzed. Building on this model, a GA-driven multi-objective calibration scheme and a coordinated optimization model jointly address axis-orthogonality correction, PM-OM extrinsic-pose calibration, and workpiece flatness compensation. Furthermore, a dynamic error-compensation framework leveraging real-time monitoring and adaptive adjustment sustains long-term high-precision marking. In post-calibration tests-after correcting axis orthogonality, aligning the PM-OM extrinsic pose, and compensating workpiece flatness, the PM system achieves dimensional accuracies of ±0.05, ±0.08, and ±0.10 μm for nominal 1, 2, and 3 μm marks, respectively, with positional accuracy better than ±0.2 μm. Marking consistency improves markedly, and the indentation force closely matches the target mark size, validating the approach. These techniques provide both theoretical and practical support for the engineering deployment of PM systems and are significant for improving the quality and productivity of micrometer-scale precision marking.