The use of the seven-wire strand in pretension structures so far has shown that such strands have a relatively long development length. An attempt to reduce the development length is reflected through the idea of a different strand geometry that has a more favorable shape. This new shape should have a greater inclination of the outer wires, increasing the resistance that occurs when moving through the concrete. The idea is primarily about the triangular distribution of wires in the cross-section of the strand. This paper reviews tests related to the use of innovative, triangular, and ten-wire strands. The tests exclusively relate to the strands formed by the use of steel wires.
On the calculation example of a cable-stayed bridge with oblique cables, it was pointed out the shrinkage and creep of concrete significantly affects the distribution of stresses and deflections of the span beam over time. The segmental type of bridge construction is considered, which implies the successive introduction of concrete rheology, for cases of controlled and free beam deflections during construction, i.e. with or without cable tightening on previously performed segments. The phenomenon of reduced sensitivity of the span beam to the effects of concrete rheology is pointed out, in case of controlled deflections by cable tightening, while without cable tightening the deflections increase over time and can negatively affect the usability of the structure. The analyses were performed using an appropriate algorithm (developed by the author) which introduced composite layered finite elements with viscous properties into the calculation.
The paper presents the results of our own experimental research on the effect of the high range water reducing admixture content – HRWRA (applied in the range from 0.8 to 1.2% by mass of cement – mc) on the properties of self-compacting concrete in the fresh and hardened state. The research showed that increasing the HRWRA content leads to the entrapped porosity reduction – up to 44%, increase of flowability – up to 13%, reduction of viscosity – up to 31%, improvement of passing ability – up to 15% and degradation of sieve segregation resistance of concrete in fresh state – up to 60%. The beneficial effect of the increase in HRWRA was shown on the analysed properties in the hardened state: compressive strength at the age of 28 days – up to 13%, water absorption – up to 61% and freeze/thaw resistance – up to 10%. The difference in the participation of HRWRA from 0.8 to 1.2% mc does not have a statistically significant effect on the density and freeze/thaw resistance with a de-icing agent.
In many countries, reinforced concrete (RC) frames are widely utilized as the primary building structure. The infill is typically composed of traditional masonry (brick elements connected with mortar), commonly without isolation from the frame. It is noted that in engineering practice, seismic force calculations for RC frame buildings are often conducted on models that exclude masonry infill, even when the infill is not isolated from the frame through specific construction elements. In such cases, the walls are considered only as a permanent load. Consequently, the contribution of non-insulated (bonded) masonry infill to changes in bearing capacity, stiffness, and ductility of the RC frame, affecting stresses and horizontal movement during seismic activity, is frequently disregarded. To assess the consequences of prevalent calculation models, four representative types of RC frame models with masonry infill were analysed herein. The study demonstrated that differently conceptualized models of the same building impact dynamic characteristics, including forces and displacements of the main frame structure. The dynamic analysis revealed that inadequate treatment of the frame and non-insulated infill connection in the design phase can lead to dangerous phenomena such as "soft floors," significant torsion, and the effects of short columns going unnoticed. Therefore, this paper underscores the importance of appropriately addressing non-insulated infill in the calculation model in routine design practices. Additionally, it advocates for the issuance of precise instructions for special construction measures that would effectively isolate masonry infill from the frame when such a solution is justified.
1 January 2025 in Građevinski materijali i konstrukcije
This study investigates the Poisson's ratio and deformation behavior of a triangular ten-wire prestressing strand in comparison to conventional seven-wire strand. Experimental tests were conducted under controlled loading to evaluate axial and lateral strains, allowing the determination of strand Poisson's ratios. The results show that ten-wire strands exhibit consistently higher Poisson's ratios (≈0.44) than seven-wire strands (≈0.33), representing an increase of approximately 25% in lateral strain response. This behavior is attributed to the triangular arrangement of wires, which provides additional wire-to-wire contacts and annular spaces, enhancing confinement and strand-concrete interaction. The findings highlight the significant influence of strand geometry on bond efficiency, transfer length, and mechanical response, providing valuable guidance for the design, calibration, and assessment of pretensioned prestressed concrete members. These results support improved predictive modeling of stress transfer and deformation behavior, contributing to more efficient and reliable prestressed concrete design.