1 January 2025 in Građevinski materijali i konstrukcije
This study investigates the Poisson's ratio and deformation behavior of a triangular ten-wire prestressing strand in comparison to conventional seven-wire strand. Experimental tests were conducted under controlled loading to evaluate axial and lateral strains, allowing the determination of strand Poisson's ratios. The results show that ten-wire strands exhibit consistently higher Poisson's ratios (≈0.44) than seven-wire strands (≈0.33), representing an increase of approximately 25% in lateral strain response. This behavior is attributed to the triangular arrangement of wires, which provides additional wire-to-wire contacts and annular spaces, enhancing confinement and strand-concrete interaction. The findings highlight the significant influence of strand geometry on bond efficiency, transfer length, and mechanical response, providing valuable guidance for the design, calibration, and assessment of pretensioned prestressed concrete members. These results support improved predictive modeling of stress transfer and deformation behavior, contributing to more efficient and reliable prestressed concrete design.