Györgyi Apponyi

Györgyi Apponyi

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2016 in Clinical Autonomic Research
Verified
Journal Article
Closed access
PDF file
OKOrsolya Kiss
Orsolya Kiss
NSNóra Sydó
Nóra Sydó
PVPéter Vargha
Péter Vargha
VHVágó Hajnalka
Vágó Hajnalka
CCCsilla Czimbalmos
Csilla Czimbalmos
BMBéla Merkely
Béla Merkely

9 December 2009 in Inflammation Research
Verified
Journal Article
Closed access
PDF file
TST. Simon
T. Simon
IJI. Jelinek
I. Jelinek
GAGyörgyi Apponyi
Györgyi Apponyi
VLV. László
V. László
ÉRÉ. Rajnavölgyi
É. Rajnavölgyi
AFA. Falus
A. Falus

24 May 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
IOIstván Osztheimer
István Osztheimer
MRMihály Ruppert
Mihály Ruppert
MNMarianna Németh
Marianna Németh
BVB Veres
B Veres
GAGyörgyi Apponyi
Györgyi Apponyi
BMBéla Merkely
Béla Merkely
Background: AVIM is a pacing algorithm incorporated into dual-chamber pacemakers to treat hypertension. AVIM delivers repeating sequences of short and longer atrioventricular delays leading to reduced preload and afterload. The therapy lowers blood pressure while simultaneously modulating the autonomic nervous system. The marked blood pressure reducing capability of AVIM has been already confirmed by a previous randomized clinical trial using conventional right ventricular (RV) pacing. Nevertheless, whether a similar blood pressure reduction could be also achieved by AVIM when conduction system pacing (CSP) is applied instead of RV pacing has not been investigated yet. Considering the facts that CSP using Left Bundle Branch Area Pacing (LBBAP) has been found to elicit more synchronous ventricular contraction and improved hemodynamics compared to RV pacing and AVIM is associated with a signficant burden of ventricular pacing, it is tempting to hypothesize that AVIM with CSP could be particularly beneficial. Purpose: To compare the effects of AVIM therapy when delivered via an LBBAP location with the effects when delivered using a traditional RV lead location. Methods: This single-center study evaluated subjects indicated for a dual chamber pacemaker who also had uncontrolled hypertension despite a stable dose of ³ 1 antihypertensive drug. Leads were placed in the RV or the LBBAP position. Subjects entered a run-in period of 4 weeks in which baseline office (oSBP)and 24-hour aSBP were measured. Subjects with baseline aSBP >130 mmHg and oSBP>140 mmHg at week 4 were included in the study. AVIM therapy was activated and a 24-hour aSBP was performed immediately after activation. Results: Using a dedicated CSP pacemaker lab setup, CSP was performed in 5 patients with the Select Secure electrode (model 3830-69 cm) delivered via a fixed curve sheath (C315HIS). During the run in phase, in 3 out of the 5 CSP-AVIM patients, high blood pressure did not reach the level of inclusion and therefore these patients were not used for further analysis. In the remaining two patients, AVIM was activated. These two patients had a V6 stimulus-peak time of 69 ms and 61 ms, while V1 stimulus peak time was: 121ms and 109ms respectively. The effect of AVIM on 24-hour aSBP in the activated CSP-AVIM patients was compared to the average effect seen in patients from the same center enrolled in the prior randomized study with leads in the RV. Table 1 shows individual aSBP values for the two patient groups. Results suggest that delivery of AVIM therapy through leads in either position generates a significant reduction in blood pressure: -24.1 mmHg vs. -15.4 mmHg when the lead is placed in LBBAP or RV positions respectively. Conclusion These results demonstrate a significant reduction in aSBP in both lead locations. Additional studies evaluating larger sample sizes are required to assess if specific lead positions are preferable.Table 1

17 January 2024 in Life
Verified
Journal Article
Open access
PDF file
KPKatalin Piros
Katalin Piros
AVAdorján Vida
Adorján Vida
NSNándor Szegedi
Nándor Szegedi
PPPéter Perge
Péter Perge
ZSZoltán Salló
Zoltán Salló
IOIstván Osztheimer
István Osztheimer
Background: Safety, efficacy, and patient comfort are the expectations during pulmonary vein isolation (PVI). We aimed to validate the combined advantages of pre- and periprocedural anticoagulation with non-vitamin K anticoagulants (NOACs) and rigorous left atrial appendage thrombus (LAAT) exclusion with computed tomography (CT). Methods: This study included a population of consecutive patients, between March 2018 and June 2020, who underwent cardiac CT within 24 h before PVI to guide the ablation and rule out LAAT. NOAC was omitted 24 h before the ablation. Results: A total of 187 patients (63% male) underwent CT before PVI. None of the patients experienced stroke during or after the procedure. The complication rate was low, with no thromboembolic events and 2.1% of patients experiencing a major bleeding event. Conclusions: Omitting NOAC 24 h before the ablation might be safe if combined with left atrial thrombus exclusion with computed tomography.