Abdullah Tahir Şensoy

Dr. Abdullah Tahir Şensoy

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2019 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
AŞAbdullah Tahir Şensoy
Abdullah Tahir Şensoy
MCMurat COLAK
Murat COLAK
IKIrfan Kaymaz
Irfan Kaymaz
FFFehim FINDIK
Fehim FINDIK

3 June 2022 in Metals and Materials International
Verified
Journal Article
Closed access
PDF file
FMFahri Murat
Fahri Murat
IKIrfan Kaymaz
Irfan Kaymaz
AŞAbdullah Tahir Şensoy
Abdullah Tahir Şensoy
IKismail hakkı korkmaz
ismail hakkı korkmaz

10 September 2020 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
AŞAbdullah Tahir Şensoy
Abdullah Tahir Şensoy
MÇMurat Çolak
Murat Çolak
IKIrfan Kaymaz
Irfan Kaymaz
DDDerya Dispinar
Derya Dispinar

23 March 2025 in Materials
Verified
Journal Article
Open access
PDF file
ICIlhan Celik
Ilhan Celik
AŞAbdullah Tahir Şensoy
Abdullah Tahir Şensoy
GSGÖKHAN SEVEN
GÖKHAN SEVEN
DCDilek Cicek
Dilek Cicek
This study presents a comprehensive analysis of the earing and thinning ratios in the deep drawing process of DD13-grade sheet metal. The variable parameters investigated include press descent speed (x1), blank holder pressure (x2) and punch pressure (x3). These parameters have been carefully selected based on production experience and preliminary experiments, and appropriate ranges of values have been established. A distinctive feature of this research is its focus on specimens with a deep drawing ratio greater than 2. The relationships between the input parameters and the response parameters were determined using the Box–Behnken design (BBD). Analysis of variance (ANOVA) for the regression models developed for earing and thinning ratios gave R2 values of 0.98 and 0.97, respectively, indicating robust predictive ability of the models. For the earing ratio, the optimal values of x1, x2 and x3 were found to be 27.38, 10 and 22, respectively. When evaluated using the same algorithm for uniform wall thickness, the optimum values were found to be 26.55, 10 and 22, respectively. The final earing and thinning ratios for all experimental runs were 3.79 and 21.19, respectively. The results of this study show that by optimizing certain parameters in the deep drawing process, the disadvantages associated with this manufacturing method can be significantly reduced.

14 September 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
NSNurdan Polat Sagsoz
Nurdan Polat Sagsoz
FMFahri Murat
Fahri Murat
SGSema Nur Sevinç Gül
Sema Nur Sevinç Gül
AŞAbdullah Tahir Şensoy
Abdullah Tahir Şensoy
IKIrfan Kaymaz
Irfan Kaymaz
This study aims to evaluate the biomechanical behavior of titanium and carbon fiber-reinforced polyetheretherketone (CF-PEEK) dental implants under varying bone densities and loading conditions using finite element analysis (FEA). A single-tooth mandibular molar implant system was modeled, comprising titanium or CF-PEEK abutment and fixture, and surrounding bone structures with four configurations: (I) fully cortical bone, (II) 2 mm cortical layer with trabecular bone, (III) 1 mm cortical with high-density trabecular bone, and (IV) 1 mm cortical with low-density trabecular bone. Vertical and oblique static loads of 100 N were applied to simulate masticatory forces. FEA results revealed that titanium implants exhibited higher von Mises stress values in the implant and abutment under oblique loading, exceeding 400 MPa, while CF-PEEK components showed reduced stress but significantly higher strain levels. Cortical and trabecular bone surrounding CF-PEEK implants received more uniform stress distribution, potentially minimizing stress shielding effects. However, fatigue life analyses indicated that CF-PEEK abutment and screw components were more susceptible to mechanical failure under oblique loads, particularly in low-density bone models. In conclusion, CF-PEEK implants offer a more physiological load transfer to bone and reduced stress shielding compared to titanium. However, their structural reliability under complex loading, especially in low-quality bone conditions, requires careful consideration. These findings support the potential use of CF-PEEK in select clinical scenarios but highlight the need for further material and design optimization.

15 June 2023 in Engineering Analysis with Boundary Elements
Verified
Journal Article
Closed access
SMSİNAN MARAŞ
SİNAN MARAŞ
AŞAbdullah Tahir Şensoy
Abdullah Tahir Şensoy