Zhiqiang Cao

Zhiqiang Cao

Auto-generated profile, based on publicly available information

Zhiqiang Cao


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SYShaohua Yan
Shaohua Yan
ZCZhiqiang Cao
Zhiqiang Cao
ZGZongxia Guo
Zongxia Guo
Zhenyi ZhengZhenyi Zheng
Zhenyi Zheng
ACAnni Cao
Anni Cao
WZWeisheng ZHAO
Weisheng ZHAO
Since the discovery of the giant magnetoresistive (GMR) effect, GMR sensors have gained much attention in last decades due to their high sensitivity, small size, and low cost. The full Wheatstone-bridge-based GMR sensor is most useful in terms of the application point of view. However, its manufacturing process is usually complex. In this paper, we present an efficient and concise approach to fabricate a full Wheatstone-bridge-based angular GMR sensor by depositing one GMR film stack, utilizing simple patterned processes, and a concise post-annealing procedure based on a special layout. The angular GMR sensor is of good linear performance and achieves a sensitivity of 0.112 mV/V/Oe at the annealing temperature of 260 °C in the magnetic field range from −50 to +50 Oe. This work provides a design and method for GMR-sensor manufacturing that is easy for implementation and suitable for mass production.

1 August 2019 in AIP Advances
Verified
Journal Article
Open access
PDF file
ZLZicong Lei
Zicong Lei
SYShaohua Yan
Shaohua Yan
ZCZhiqiang Cao
Zhiqiang Cao
ZGZongxia Guo
Zongxia Guo
PSPanshen Song
Panshen Song
QLQunwen Leng
Qunwen Leng
We systematically studied the characteristics and influence of free layer thickness in magnetic tunnel junction (MTJ) with a perpendicular synthetic antiferromagnetic (p-SAF) reference layer on 8-inch wafer. The results show clearly that there is an optimal thickness of free layer to achieve the highest tunneling magnetoresistance (TMR) ratio of as high as 80.5% and 53.7% with perpendicular and in-plane magnetic field, respectively, while the resistance-area product (RA) reaches also highest value of 21.1 Ω*μm2. The thickness range of CoFeB to obtain perpendicular magnetic anisotropy (PMA) is determined. The variation of the magnetic moment of free layer indicates that the three-dimensional (3D) sensors can be designed by varying the thickness of the free layer and be controlled by the perpendicular and in-plane components through annealing under the in-plane magnetic field.

1 September 2025 in Frontiers in Electronics
Verified
Journal Article
Open access
PDF file
JZJunbiao Zhao
Junbiao Zhao
LBLigang Bai
Ligang Bai
SLShen Li
Shen Li
ZCZhiqiang Cao
Zhiqiang Cao
YPYi Peng
Yi Peng
XZXueying ZHANG
Xueying ZHANG
Magnetic materials play a pivotal role in emerging fields such as new energy, information technology, and biomedicine, where accurate magnetic characterization is essential for material innovation and device engineering. Notably, with the burgeoning development of nanomaterials and spintronics, the importance of magnetic characterization has grown significantly, accompanied by increasingly higher requirements for precision and multi-dimensional analysis. This paper elaborates on the working principles and structural components of static magnetic measurement techniques—including Vibrating Sample Magnetometer (VSM), Alternating Gradient Magnetometer (AGM), Magneto-Optical Kerr Effect (MOKE) Microscope, Magnetic Force Microscope (MFM) and Superconducting Quantum Interference Device (SQUID) Magnetometer, as well as dynamic magnetic measurement techniques such as Alternating Current (AC) susceptometry and Ferromagnetic Resonance (FMR). In addition, this review also introduces emerging techniques relevant to spintronics, including Magnetometer based on negatively charged nitrogen-vacancy (NV−) centers in diamond, Spin-polarized Scanning Tunneling Microscope (SP-STM), Lorentz Transmission Electron Microscope (LTEM), and Soft X-ray-based techniques, highlighting their principles and applications in quantum sensing, magnetic imaging, and element-specific spin analysis. This overview emphasizes the unique capabilities and measurement principles of each magnetic characterization instrument, providing users with practical guidance to identify the most appropriate tool based on specific research objectives, material properties, and experimental requirements, thereby improving characterization efficiency and accuracy.

22 March 2021 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
ZCZhiqiang Cao
Zhiqiang Cao
WCWeibin Chen
Weibin Chen
SLShiyang Lu
Shiyang Lu
SYShaohua Yan
Shaohua Yan
YZYu Zhang
Yu Zhang
QLQunwen Leng
Qunwen Leng
A double-interface CoFeB/MgO perpendicular tunnel magnetoresistance (p-TMR) structure has been proposed as a solution to improve the thermal stability of perpendicular magnetic tunnel junction (MTJ)-based devices. In this paper, we have investigated the performance of TMR film stacks by varying the thickness of the MgO cap layer. The resistance area (RA) product and TMR ratio are characterized using a current-in-plane tunneling system. Structural and physical analyses are performed using transmission electron microscopy and a superconducting quantum interference device. It is found that the sensing layer is able to exhibit a linear output and sensitivity up to 0.25% MR/Oe as the thickness of the MgO cap layer is lowered to 0.7 nm. The RA product increases as the thickness of the MgO cap layer decreases under 0.8 nm, which is attributed to oxidization of the CoFeB layer. This research provides a valuable direction to the optimization of double-interface CoFeB/MgO p-TMR and the sensor design in terms of linear magnetic field range and sensor RA product target for sensor applications.

6 August 2025 in NeuroImage
Verified
Journal Article
Open access
RWRuonan Wang
Ruonan Wang
YMYujie Ma
Yujie Ma
RZRuochen Zhao
Ruochen Zhao
JDJin Ding
Jin Ding
LLLing Li
Ling Li
XNXiaolin Ning
Xiaolin Ning
Magnetoencephalography (MEG) is a non-invasive imaging technique that captures neural activity with high spatio-temporal resolution. In recent years, novel wearable devices based on Optically Pumped Magnetometer (OPM) have emerged as a new driving force for advancing MEG due to their cost-effectiveness, portability, and mobility. In practical applications, MEG signals are frequently influenced by various interference sources, resulting in degradation of signal quality. Consequently, numerous suppression techniques have been proposed to overcome these challenges. This manuscript presents a comprehensive review of the most advanced methods for suppressing MEG noise or artifacts, with a specific focus on mitigating background noise, physiological artifacts (such as those caused by heartbeat, eye movements, and muscle contractions), as well as technical artifacts (including system-related artifacts associated with devices, motion-induced artifacts, and metal-induced artifacts). Additionally, the current limitations and challenges of these approaches in real-world scenarios are highlighted. Reviewing nearly a decade of research, there is an urgent need for a lightweight noise analysis framework in the complex measurement environment of wearable OPM-MEG devices. This framework should be capable of effectively detecting, classifying, and suppressing individual and combined MEG interference. By addressing this need, we can enhance the reliability and practicality of MEG signals while advancing brain science research.

1 January 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
YSYuzu Sun
Yuzu Sun
QXQingtao Xia
Qingtao Xia
DZDandan Zhang
Dandan Zhang
QMQianqian Mou
Qianqian Mou
YLYunpeng Li
Yunpeng Li
WZWeisheng ZHAO
Weisheng ZHAO
For tunneling magnetoresistance (TMR) sensors using magnetic tunnel junctions (MTJ), the sensor output linearization is of great importance for practical applications. The current study employs a three-step magnetic annealing procedure for linearizing the double-pinned MTJs, setting the magnetization of the free layer to be orthogonal to that of the reference layer. Compared to the traditional two-step annealing procedure, the three-step annealing procedure benefits from a lower annealing temperature and excellent linearity performance. Utilizing the three-step annealing procedure, the sensitivity and the detectivity of 1.57 mV/V/Oe and 29.3 nT Hz0.5 @ 10 Hz, respectively, was achieved in a full Wheatstone bridge TMR sensor. Our results reveal a new pathway for linearization of the TMR sensors through three-step annealing process.