Carlos Antón Gil

Dr. Carlos Antón Gil


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2007 in Cement and Concrete Research
Verified
Journal Article
Closed access
GVGuillem de Vera
Guillem de Vera
Miguel-Ángel ClimentMiguel-Ángel Climent
Miguel-Ángel Climent
EVEstanislao Viqueira
Estanislao Viqueira
CGCarlos Antón Gil
Carlos Antón Gil
CACarmen Andrade
Carmen Andrade

1 February 2010 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Open access
GVG. de Vera
G. de Vera
Miguel-Ángel ClimentMiguel-Ángel Climent
Miguel-Ángel Climent
CGCarlos Antón Gil
Carlos Antón Gil
AHA. Hidalgo
A. Hidalgo
CAC. Andrade
C. Andrade
The measurement of the free chloride concentration in the pore solution of cement paste or concrete is of interest for assessing the probability of corrosion of the steel reinforcements embedded in concrete. This determination is performed through leaching or pore-pressing methods or through embedded potentiometric sensors into the hardened cementitious material. The potentiometric determination of chloride in cement paste pore solutions is limited by hydroxide ion interference, due to the high alkalinity of such media. The potentiometric selectivity coefficients, kCl-,OH-, are determined for a chloride ionic selective electrode in alkaline solutions simulating the electrolyte present within the pore network of cement paste and concrete. This is done using a fixed interference methodology, with least-squares non-linear curve fitting for obtaining the selectivity coefficients together with other relevant electrode parameters. The limit of detection of the Cl− ISE, due to OH− interference, varies with pH. For the pore solution corresponding to an ordinary Portland cement paste or concrete, this limit can be set between 3 × 10–3 m, and 7 × 10–3 m, i.e., approximately below a chloride concentration value of 1 × 10–2 molal. Taking into account these limits of detection the free Cl− concentrations able to depassivate the steel, can be adequately determined by potentiometric measurements with calibrated ISEs in the expressed pore solutions of Portland cement concretes, without significant influence of OH− interference. Nevertheless, this effect can prevent the adequate measurement of low free Cl− concentrations, below the corresponding limit of detection valu

25 July 2013 in Journal of Nondestructive Evaluation
Verified
Journal Article
Closed access
PDF file
ISIsidro Sánchez
Isidro Sánchez
CGCarlos Antón Gil
Carlos Antón Gil
GVG. de Vera
G. de Vera
José Marcos OrtegaJosé Marcos Ortega
José Marcos Ortega
Miguel-Ángel ClimentMiguel-Ángel Climent
Miguel-Ángel Climent

27 November 2012 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
CGCarlos Antón Gil
Carlos Antón Gil
Miguel-Ángel ClimentMiguel-Ángel Climent
Miguel-Ángel Climent
GVGuillem de Vera
Guillem de Vera
ISIsidro Sánchez
Isidro Sánchez
CACarmen Andrade
Carmen Andrade

30 March 2013 in Materiales de Construcción
Verified
Journal Article
Open access
PDF file
Beatriz del MoralBeatriz del Moral
Beatriz del Moral
Oscar GalaoOscar Galao
Oscar Galao
CGCarlos Antón Gil
Carlos Antón Gil
Miguel-Ángel ClimentMiguel-Ángel Climent
Miguel-Ángel Climent
PGPedro Garcés
Pedro Garcés
In the application of the electrochemical chloride extraction (ECE) technique, traditionally, the Ti-RuO2 wire netting has been used as the external anode. This article provides the results of the research based on the use of conductive cement paste with addition of carbon nanofibers (CNF) as anodes and its application in ECE. The tests were developed in concrete specimens previously contaminated with chloride. The efficiencies achieved were compared with those obtained using a traditional anode (Ti-RuO2) and cement pastes with the addition of other carbonaceous materials. The results show the feasibility of using conductive cement paste with CNF as the anode in the electrochemical extraction of chlorides in concrete, finding similar efficiencies to those obtained with traditional Ti-RuO2 wire netting but with the added advantage that it can be adapted to complex structural geometries as it can be applied as a paste.

26 May 2015 in Materials
Verified
Journal Article
Open access
PDF file
JCJesús Carmona Calero
Jesús Carmona Calero
Miguel-Ángel ClimentMiguel-Ángel Climent
Miguel-Ángel Climent
CGCarlos Antón Gil
Carlos Antón Gil
PGPedro Garcés
Pedro Garcés
PGPedro Garcés
Pedro Garcés
This article shows the research carried out by the authors focused on how the shape of structural reinforced concrete elements treated with electrochemical chloride extraction can affect the efficiency of this process. Assuming the current use of different anode systems, the present study considers the comparison of results between conventional anodes based on Ti-RuO2 wire mesh and a cement-based anodic system such as a paste of graphite-cement. Reinforced concrete elements of a meter length were molded to serve as laboratory specimens, to closely represent authentic structural supports, with circular and rectangular sections. Results confirm almost equal performances for both types of anode systems when electrochemical chloride extraction is applied to isotropic structural elements. In the case of anisotropic ones, such as rectangular sections with no uniformly distributed rebar, differences in electrical flow density were detected during the treatment. Those differences were more extreme for Ti-RuO2 mesh anode system. This particular shape effect is evidenced by obtaining the efficiencies of electrochemical chloride extraction in different points of specimens.