In this article, we focus on the opacity issue of sub-symbolic machine learning predictors by promoting two complementary activities— symbolic knowledge extraction (SKE) and symbolic knowledge injection (SKI)—from and into sub-symbolic predictors. We consider as symbolic any language being intelligible and interpretable for both humans and computers. Accordingly, we propose general meta-models for both SKE and SKI, along with two taxonomies for the classification of SKE and SKI methods. By adopting an explainable artificial intelligence (XAI) perspective, we highlight how such methods can be exploited to mitigate the aforementioned opacity issue. Our taxonomies are attained by surveying and classifying existing methods from the literature, following a systematic approach, and by generalising the results of previous surveys targeting specific sub-topics of either SKE or SKI alone. More precisely, we analyse 132 methods for SKE and 117 methods for SKI, and we categorise them according to their purpose, operation, expected input/output data and predictor types. For each method, we also indicate the presence/lack of runnable software implementations. Our work may be of interest for data scientists aiming at selecting the most adequate SKE/SKI method for their needs, and may also work as suggestions for researchers interested in filling the gaps of the current state-of-the-art as well as for developers willing to implement SKE/SKI-based technologies.
Context.Cubic gold-platinum free-falling test masses (TMs) constitute the mirrors of future LISA and LISA-like interferometers for low-frequency gravitational wave detection in space. High-energy particles of Galactic and solar origin charge the TMs and thus induce spurious electrostatic and magnetic forces that limit the sensitivity of these interferometers. Prelaunch Monte Carlo simulations of the TM charging were carried out for the LISA Pathfinder (LPF) mission, that was planned to test the LISA instrumentation. Measurements and simulations were compared during the mission operations. The measured net TM charging agreed with simulation estimates, while the charging noise was three to four times higher.Aims.We aim to bridge the gap between LPF TM charging noise simulations and observations.Methods.New Monte Carlo simulations of the LPF TM charging due to both Galactic and solar particles were carried out with the FLUKA/LEI toolkit. This allowed propagating low-energy electrons down to a few electronvolt.Results.These improved FLUKA/LEI simulations agree with observations gathered during the mission operations within statistical and Monte Carlo errors. The charging noise induced by Galactic cosmic rays is about one thousand charges per second. This value increases to tens of thousands charges per second during solar energetic particle events. Similar results are expected for the LISA TM charging.
Hydrogenated amorphous silicon (a-Si:H) is a material having an intrinsically high radiation hardness that can be deposited on flexible substrates like Polyimide. For these properties a-Si:H can be used for the production of flexible sensors. a-Si:H sensors can be successfully utilized in dosimetry, beam monitoring for particle physics (x-ray, electron, gamma-ray and proton detection) and radiotherapy, radiation flux measurement for space applications (study of solar energetic particles and stellar events) and neutron flux measurements. In this paper we have studied the dosimetric x-ray response of n-i-p diodes deposited on Polyimide. We measured the linearity of the photocurrent response to x-rays versus dose-rate from which we have extracted the dosimetric x-ray sensitivity at various bias voltages. In particular low bias voltage operation has been studied to assess the high energy efficiency of these kind of sensor. A measurement of stability of x-ray response versus time has been shown. The effect of detectors annealing has been studied. Operation under bending at various bending radii is also shown.
Objective. Microbeam radiation therapy (MRT) is an alternative emerging radiotherapy treatment modality which has demonstrated effective radioresistant tumour control while sparing surrounding healthy tissue in preclinical trials. This apparent selectivity is achieved through MRT combining ultra-high dose rates with micron-scale spatial fractionation of the delivered x-ray treatment field. Quality assurance dosimetry for MRT must therefore overcome a significant challenge, as detectors require both a high dynamic range and a high spatial resolution to perform accurately. Approach. In this work, a series of radiation hard a-Si:H diodes, with different thicknesses and carrier selective contact configurations, have been characterised for x-ray dosimetry and real-time beam monitoring applications in extremely high flux beamlines utilised for MRT at the Australian Synchrotron. Results. These devices displayed superior radiation hardness under constant high dose-rate irradiations on the order of 6000 Gy s−1, with a variation in response of 10% over a delivered dose range of approximately 600 kGy. Dose linearity of each detector to x-rays with a peak energy of 117 keV is reported, with sensitivities ranging from (2.74 ± 0.02) nC/Gy to (4.96 ± 0.02) nC/Gy. For detectors with 0.8 μm thick active a-Si:H layer, their operation in an edge-on orientation allows for the reconstruction of micron-size beam profiles (microbeams). The microbeams, with a nominal full-width-half-max of 50 μm and a peak-to-peak separation of 400 μm, were reconstructed with extreme accuracy. The full-width-half-max was observed as 55 ± 1 μm. Evaluation of the peak-to-valley dose ratio and dose-rate dependence of the devices, as well as an x-ray induced charge (XBIC) map of a single pixel is also reported. Significance. These devices based on novel a-Si:H technology possess a unique combination of accurate dosimetric performance and radiation resistance, making them an ideal candidate for x-ray dosimetry in high dose-rate environments such as FLASH and MRT.
The Laser Interferometer Space Antenna (LISA) of the European Space Agency (ESA) will be the first low-frequency gravitational-wave observatory orbiting the Sun at 1 AU. The LISA Pathfinder (LPF) mission, aiming at testing the instruments to be located on board the LISA spacecraft (S/C), hosted, among the others, fluxgate magnetometers and a particle detector as parts of a diagnostics subsystem. These instruments allowed us to estimate the magnetic and Coulomb spurious forces acting on the test masses that constitute the mirrors of the interferometer. With these instruments, we also had the possibility to study the galactic cosmic-ray short term-term variations as a function of the particle energy and the associated interplanetary disturbances. Platform magnetometers and particle detectors will also be placed on board each LISA S/C. This work reports on an empirical method that allowed us to disentangle the interplanetary and onboard-generated components of the magnetic field by using the LPF magnetometer measurements. Moreover, we estimate the number and fluence of solar energetic particle events expected to be observed with the ESA Next Generation Radiation Monitor during the mission lifetime. An additional cosmic-ray detector, similar to that designed for LPF, in combination with magnetometers, would permit to observe the evolution of recurrent and non-recurrent galactic cosmic-ray variations and associated increases of the Interplanetary Magnetic Field at the transit of high-speed solar wind streams and interplanetary counterparts of coronal mass ejections. The diagnostics subsystem of LISA makes this mission also a natural multi-point observatory for space weather science investigations.