Juzhong Zhang

Dr. Juzhong Zhang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
YWYuwen Wu
Yuwen Wu
ZWZhisen Wang
Zhisen Wang
YCYuyi Chu
Yuyi Chu
RPRenyuan Peng
Renyuan Peng
HPHaoran Peng
Haoran Peng
JZJuzhong Zhang
Juzhong Zhang
Malignant tumors have become one of the serious public health problems in human safety and health, among which the chest and abdomen diseases account for the largest proportion. Early diagnosis and treatment can effectively improve the survival rate of patients. However, respiratory motion in the chest and abdomen can lead to uncertainty in the shape, volume, and location of the tumor, making treatment of the chest and abdomen difficult. Therefore, compensation for respiratory motion is very important in clinical treatment. The purpose of this review was to discuss the research and development of respiratory movement monitoring and prediction in thoracic and abdominal surgery, as well as introduce the current research status. The integration of modern respiratory motion compensation technology with advanced sensor detection technology, medical-image-guided therapy, and artificial intelligence technology is discussed and analyzed. The future research direction of intraoperative thoracic and abdominal respiratory motion compensation should be non-invasive, non-contact, use a low dose, and involve intelligent development. The complexity of the surgical environment, the constraints on the accuracy of existing image guidance devices, and the latency of data transmission are all present technical challenges.

27 April 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
YWYuwen Wu
Yuwen Wu
Kai GuoKai Guo
Kai Guo
YCYuyi Chu
Yuyi Chu
ZWZhisen Wang
Zhisen Wang
Hongbo YangHongbo Yang
Hongbo Yang
JZJuzhong Zhang
Juzhong Zhang
Dysphagia is a pervasive health issue that impacts diverse demographic groups worldwide, particularly the elderly, stroke survivors, and those suffering from neurological disorders. This condition poses substantial health risks, including malnutrition, respiratory complications, and increased mortality. Additionally, it exacerbates economic burdens by extending hospital stays and escalating healthcare costs. Given that this disorder is frequently underestimated in vulnerable populations, there is an urgent need for enhanced diagnostic and therapeutic strategies. Traditional diagnostic tools such as the videofluoroscopic swallowing study (VFSS) and flexible endoscopic evaluation of swallowing (FEES) require interpretation by clinical experts and may lead to complications. In contrast, non-invasive sensors offer a more comfortable and convenient approach for assessing swallowing function. This review systematically examines recent advancements in non-invasive swallowing function detection devices, focusing on the validation of the device designs and their implementation in clinical practice. Moreover, this review discusses the swallowing process and the associated biomechanics, providing a theoretical foundation for the technologies discussed. It is hoped that this comprehensive overview will facilitate a paradigm shift in swallowing assessments, steering the development of technologies towards more accessible and accurate diagnostic tools, thereby improving patient care and treatment outcomes.

29 November 2025 in Actuators
Verified
Journal Article
Open access
PDF file
ZWZhisen Wang
Zhisen Wang
JZJuzhong Zhang
Juzhong Zhang
YCYuyi Chu
Yuyi Chu
YWYuwen Wu
Yuwen Wu
YMYifan Mou
Yifan Mou
Hongbo YangHongbo Yang
Hongbo Yang
Serial-parallel hybrid manipulators featuring remote actuation via parallelogram mechanisms are highly valued for their low inertia and high stiffness. However, the complex nonlinear errors introduced by their multi-stage transmission chains pose significant challenges for high-precision calibration. To address this, this paper proposes a hierarchical and decoupled calibration framework specifically tailored for such parallelogram-driven hybrid manipulators. The method first independently calibrates the pose error of the 3-DOF serial main arm using a composite error model that integrates transmission chain constraints. Subsequently, the 2-DOF parallel wrist is accurately calibrated employing a joint-space error identification strategy based on inverse kinematics, thereby circumventing the intractability of solving the parallel mechanism’s forward kinematics. Experimental validation was performed on a self-developed 5-DOF robot prototype using an optical tracker and an attitude sensor. Results from the validation dataset demonstrate that the proposed method reduces the robot’s average positioning error from 2.199 mm to 0.658 mm (a 70.1% improvement) and the average attitude error from 0.8976 deg to 0.1767 deg (an 80.3% improvement). Furthermore, comparative experiments against the standard MDH model and polynomial fitting models confirm that the proposed composite error model and multi-stage transmission error model are essential for achieving high accuracy. This research provides crucial theoretical insights and practical solutions for the high-precision application of complex remote-driven hybrid manipulators.

15 June 2026 in Advanced Science
Verified
Journal Article
Open access
JLJiuqiang Li
Jiuqiang Li
SZsenhao zhang
senhao zhang
Kai GuoKai Guo
Kai Guo
DQDonghai Qiu
Donghai Qiu
JZJuzhong Zhang
Juzhong Zhang
Larry ChengLarry Cheng
Larry Cheng
Long‐term and high‐fidelity electrophysiological (EP) signal monitoring with conformal epidermal electrodes with low contact impedance and robustness against motion artifacts is of great significance for health monitoring and human–machine interfaces. However, the low‐cost yet scalable fabrication of large‐area electrodes and arrays with these desired properties remains challenging. Here, a facile strategy is reported to fabricate large‐area, highly conformal, and low‐impedance epidermal electrodes based on highly porous and conductive laser‐induced graphene (LIG) nanocomposites. The patterned superhydrophilic LIG allows the self‐selective wetting of silver ionic solutions into the porous structure, followed by reduction to form LIG–Ag nanocomposites with significantly reduced sheet resistance (from 50 to 0.06 Ω/sq) and also the skin contact impedance. Subsequent transfer of the nanocomposites onto an ultrathin (13 µm) styrene‐ethylene‐butylene‐styrene (SEBS) substrate results in durable, highly conformal, and low‐impedance epidermal electrodes even after storage for over 8 months. The resulting electrodes demonstrate superior signal‐to‐noise ratio (SNR) and resistance against motion artifacts for EP signal monitoring. The twelve‐lead ECG monitoring and biopotential‐based control of a robotic hand demonstrate the practical utility of these electrodes for clinical health monitoring and human–machine interactions.