In 2015, U.K. newborn screening (NBS) laboratory guidelines were introduced to standardize dried blood spot (DBS) specimen quality acceptance and specify a minimum acceptable DBS diameter of ≥7 mm. The UK ‘acceptable’ avoidable repeat rate (AVRR) is ≤2%. To assess inter-laboratory variability in specimen acceptance/rejection, two sets of colored scanned images (n = 40/set) of both good and poor-quality DBS specimens were distributed to all 16 U.K. NBS laboratories for evaluation as part of an external quality assurance (EQA) assessment. The mean (range) number of specimens rejected in the first EQA distribution was 7 (1–16) and in the second EQA distribution was 7 (0–16), demonstrating that adherence to the 2015 guidelines was highly variable. A new minimum standard for DBS size of ≥8 mm (to enable a minimum of six sub-punches from two DBS) was discussed. NBS laboratories undertook a prospective audit and demonstrated that using ≥8 mm as the minimum acceptable DBS diameter would increase the AVRR from 2.1% (range 0.55% to 5.5%) to 7.8% (range 0.55% to 22.7%). A significant inverse association between the number of specimens rejected in the DBS EQA distributions and the predicted AVVR (using ≥8 mm minimum standard) was observed (r = −0.734, p = 0.003). Before implementing more stringent standards, the impact of a standard operating procedure (SOP) designed to enable a standardized approach of visual assessment and using the existing ≥7 mm diameter (to enable a minimum of four sub-punches from two DBS) as the minimum standard was assessed in a retrospective audit. Implementation of the SOP and using the ≥7 mm DBS diameter would increase the AVRR from 2.3% (range 0.63% to 5.3%) to 6.5% (range 4.3% to 20.9%). The results demonstrate that there is inconsistency in applying the acceptance/rejection criteria, and that a low AVVR is not an indication of good-quality specimens being received into laboratories. Further work is underway to introduce and maintain standards without increasing the AVRR to unacceptable levels.

Verified
Journal Article
Open access
PDF file
RCRachel Carling
Rachel Carling
KHKaty Hedgethorne
Katy Hedgethorne
ACAnupam Chakrapani
Anupam Chakrapani
PHPatricia Hall
Patricia Hall
Nick FlynnNick Flynn
Nick Flynn
James BonhamJames Bonham
James Bonham
Since the UK commenced newborn screening for isovaleric acidemia in 2015, changes in prescribing have increased the incidence of false positive (FP) results due to pivaloylcarnitine. A review of screening results between 2015 and 2022 identified 24 true positive (TP) and 84 FP cases, with pivalate interference confirmed in 76/84. Initial C5 carnitine (C5C) did not discriminate between FP and TP with median (range) C5C of 2.9 (2.0–9.6) and 4.0 (1.8–>70) µmol/L, respectively, and neither did Precision Newborn Screening via Collaborative Laboratory Integrated Reports (CLIR), which identified only 1/47 FP cases. However, among the TP cases, disease severity showed a correlation with initial C5C in ‘asymptomatic’ individuals (n = 17), demonstrating a median (range) C5C of 3.0 (1.8–7.1) whilst ‘clinically affected’ patients (n = 7), showed a median (range) C5C of 13.9 (7.7–70) µmol/L. These findings allowed the introduction of dual cut-off values into the screening algorithm to reduce the incidence of FPs, with initial C5C results ≥ 5 µmol/L triggering urgent referral, and those >2.0 and <5.0 µmol/L prompting second-tier C5-isobar testing. This will avoid delayed referral in babies at particular risk whilst reducing the FP rate for the remainder.

24 January 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
RCRachel Carling
Rachel Carling
KHKaty Hedgethorne
Katy Hedgethorne
ACAnupam Chakrapani
Anupam Chakrapani
PHPatricia Hall
Patricia Hall
Nick FlynnNick Flynn
Nick Flynn
James BonhamJames Bonham
James Bonham
Since the UK commenced newborn screening for isovaleric acidemia in 2015, changes in prescribing have increased the incidence of false positive (FP) results due to pivaloylcarnitine. A review of screening results between 2015-22 identified 24 true positive (TP) and 84 FP cases, with pivalate interference confirmed in 76/84. Initial C5 carnitine (C5C) did not discriminate between FP and TP with median (range) C5C of 2.9 (2.0 - 9.6) and 4.0 (1.8 - >70) µmol/L respectively and neither did Precision Newborn Screening via Collaborative Laboratory Integrated Reports (CLIR), which identified only 1/47 FP cases. However, among the TP cases, disease severity showed a correlation with initial C5C, in ‘asymptomatic’ individuals (n=17), demonstrating a median (range) C5C of 3.0 (1.8 – 7.1) whilst ‘clinically affected’ patients (n=7), showed a median (range) C5C of 13.9 (7.7 - > 70) µmol/L. These findings allowed the introduction of dual cut-off values into the screening algorithm to reduce the incidence of FPs, with initial C5C results ≥ 5 µmol/L triggering urgent referral, and those > 2.0 and < 5.0 µmol/L prompting 2nd tier C5-isobar testing. This will avoid delayed referral in babies at particular risk whilst reducing the FP rate for the remainder.

Verified
Journal Article
Open access
PDF file
RCRachel Carling
Rachel Carling
ZBZoe J. Barclay
Zoe J. Barclay
SWSophie C Ward
Sophie C Ward
MAMarie Appleton
Marie Appleton
RBRobert Barski
Robert Barski
James BonhamJames Bonham
James Bonham
Newborn screening in England is a national program with laboratories adhering to common screening algorithms. Until recently, screening for inherited metabolic disorders was provided by ten laboratories using laboratory-developed tests (LDTs) and three using commercial assays: harmonization of results proved challenging. Introduction of hereditary tyrosinemia type 1 screening meant LDTs required modification to include the measurement of succinylacetone, and subsequent re-validation. This provided an opportunity to implement a single commercial reagent kit in all laboratories. It was anticipated that this would improve analytical performance and harmonization. This study aimed to determine whether these goals were achieved. Verification across the 13 laboratories revealed that the commercial kit reduced inter-laboratory variation for all analytes demonstrating improved harmonization. However, this was achieved by applying instrument-specific correction factors to all analytes, the magnitude of which were significant, indicating a lack of standardization. Performance of succinylacetone was limited by instrument-dependent background interference from the methionine stable isotope label, underscoring the need to establish evidence-based screening cut-off values (COV) rather than adopting published thresholds. This study emphasizes the need for traceable reference materials to improve laboratory quality and the value of screening outcome data.

Verified
Journal Article
Open access
PDF file
TGToby Greenfield
Toby Greenfield
LTLESLEY JACQUELINE TETLOW
LESLEY JACQUELINE TETLOW
James BonhamJames Bonham
James Bonham
CCCatherine Collingwood
Catherine Collingwood
LWLaura Wainwright
Laura Wainwright
MDMaya Desai
Maya Desai
Increasing ethnic diversity raises potential inequalities within screening programmes. In the UK, newborns are screened for CF by initially measuring IRT. Dried blood spot IRT levels above a set cut-off require follow-up testing to establish a screening result. Variation exists in IRT levels between different ethnicities and therefore impacts the number of potentially false positive results obtained from ethnic groups. Over a 4-year period, IRT data was collected, and the 99.5th centile was calculated for different ethnic groups. Significant differences were noticed between ethnic groups, and the CF outcome data over a 10-year period were then analysed to establish the effect this had on positive predictive values. The largest difference in IRT 99.5th centile values was seen between the White British and Black African groups. Positive predictive values for Black African and Indian ethnic groups were much lower than the other groups. Rather than try to incorporate ethnicity into the UK CF screening algorithm, we suggest making CF clinicians aware of the differences between different ethnic groups to inform counselling families who receive screen-positive results.