Paul Corstjens

Dr. Paul Corstjens

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2014 in Parasitology
Verified
Journal Article
Closed access
PDF file
PCPaul Corstjens
Paul Corstjens
CDClaudia J. DE Dood
Claudia J. DE Dood
DKDieuwke Kornelis
Dieuwke Kornelis
EFElisa M. Tjon Kon Fat
Elisa M. Tjon Kon Fat
RWR. Alan Wilson
R. Alan Wilson
GDGovert J. VAN Dam
Govert J. VAN Dam
SUMMARY: The potential of various quantitative lateral flow (LF) based assays utilizing up-converting phosphor (UCP) reporters for the diagnosis of schistosomiasis is reviewed including recent developments. Active infections are demonstrated by screening for the presence of regurgitated worm antigens (genus specific polysaccharides), whereas anti-Schistosomaantibodies may indicate ongoing as well as past infections. The circulating anodic antigen (CAA) in serum or urine (and potentially also saliva) is identified as the marker that may allow detection of single-worm infections. Quantitation of antigen levels is a reliable method to study effects of drug administration, worm burden and anti-fecundity mechanisms. Moreover, the ratio of CAA and circulating cathodic antigen (CCA) is postulated to facilitate identification of eitherSchistosoma mansoniorSchistosoma haematobiuminfections. The UCP-LF assays allow simultaneous detection of multiple targets on a single strip, a valuable feature for antibody detection assays. Although antibody detection in endemic regions is not a useful tool to diagnose active infections, it gains potential when the ratio of different classes of antibody specific for the parasite/disease can be determined. The UCP-LF antibody assay format allows this type of multiplexing, including testing a linear array of up to 20 different targets. Multiple test spots would allow detection of specific antibodies, e.g. against differentSchistosomaspecies or other pathogens as soil-transmitted helminths. Concluding, the different UCP-LF based assays for diagnosis of schistosomiasis provide a collection of tests with relatively low complexity and high sensitivity, covering the full range of diagnostics needed in control programmes for mapping, screening and monitoring.

1 October 2001 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
PCPaul Corstjens
Paul Corstjens
MZMichel Zuiderwijk
Michel Zuiderwijk
ABAntoinette Brink
Antoinette Brink
SLShang Li
Shang Li
HFHans Feindt
Hans Feindt
HTHans Tanke
Hans Tanke
Background: A lateral-flow (LF) device using the new reporter up-converting phosphor technology (UPTTM) was applied to DNA (hybridization) assays for the detection of specific nucleic acid sequences, thereby aiming to perform the test outside well-equipped laboratories. The methodology reported here is sensitive and provides a rapid alternative for more elaborate gel electrophoresis and Southern blotting. In a preliminary study, it was applied to screen for the presence of human papillomavirus type 16 (HPV16) in a defined series of cervical carcinomas. Methods: A LF assay was used to capture haptenized DNA molecules and hybrids, which were immunolabeled (before LF) with 400-nm UPT particles. These particles emit visible light after excitation with infrared in a process called up-conversion. Because up-conversion occurs in only the phosphor lattice, autofluorescence of other assay components is virtually nonexistent. Results: The use of the UPT reporter in LF-DNA tests, as compared with colloidal gold, improved the detection limit at least 100-fold. UPT LF-DNA tests were successfully applied to detect (in a blind test) the presence of HPV16 in DNA extracts obtained from cervical carcinomas. Test results matched 100% with previous characterization of these carcinomas. Conclusions: The use of UPT in LF assays to detect specific nucleic acids provides low attamole-range sensitivity. Hybridization and consecutive detection of PCR-amplified HPV16 sequences were successful in a background of 10 μg of fish-sperm DNA. The sensitivity of UPT detection in these complex mixtures indicates that detection of viral infections without PCR or other amplification technique is achievable.

17 April 2010 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
DCDafeng Chen
Dafeng Chen
MMMichael Mauk
Michael Mauk
XQXianbo Qiu
Xianbo Qiu
CLChangchun Liu
Changchun Liu
JKJitae Kim
Jitae Kim
HBHaim H Bau
Haim H Bau

1 July 2000 in Journal of Biological Chemistry
Verified
Journal Article
Open access
FMFrédéric Marin
Frédéric Marin
PCPaul Corstjens
Paul Corstjens
BGBéatrice de Gaulejac
Béatrice de Gaulejac
EJElizabeth de Vrind-De Jong
Elizabeth de Vrind-De Jong
PWPeter Westbroek
Peter Westbroek
A cDNA expression library constructed from mantle tissue mRNA of the Mediterranean fan mussel Pinna nobilis was screened with antibodies raised against the acetic acid-soluble shell matrix of the same species. This resulted in the isolation of a 2138-base pair cDNA, containing 13 tandem repeats of 93 base pairs. The deduced protein has a molecular mass of 66.7 kDa and a isoelectric point of 4.8. This protein, which is enriched in serine and proline residues, was overexpressed, purified, and used for producing polyclonal antibodies. Immunological in situ and in vitro tests showed that the protein is localized in the nacreous aragonitic layer of P. nobilis, but not in the calcitic prisms. Because this protein of the nacre of P. nobilis exhibits some mucin-like characteristics, we propose the name mucoperlin. This is the first paper reporting the cloning of a molluscan mucin and the first molecular evidence for the involvement of a mucin in molluscan calcification. This finding corroborates our previous hypothesis that some of the proteinaceous constituents of the molluscan shell matrix would derive from mucins, common to many metazoan lineages of the late Precambrian (Marin, F., Smith, M., Isa, Y., Muyzer, G. and Westbroek, P. (1996) Proc. Natl. Acad. Sci. U. S. A. 93, 1554-1559). The adaptation of an ancestral mucin to a new function, the regulation of the mineralization process, may be one of the molecular events, among others, that would explain the simultaneous emergence of organized calcification in many metazoan lineages during the Cambrian explosion.

1 January 2008 in Journal of Clinical Microbiology
Verified
Journal Article
Closed access
PCPaul Corstjens
Paul Corstjens
LLLisette van Lieshout
Lisette van Lieshout
MZMichel Zuiderwijk
Michel Zuiderwijk
DKDieuwke Kornelis
Dieuwke Kornelis
HTHans J. Tanke
Hans J. Tanke
GDGovert J. van Dam
Govert J. van Dam
Schistosoma sp. circular anodic antigen (CAA) serum concentrations reflect actual worm burden in a patient and are a valuable tool for population screening and epidemiological research. However, for the diagnosis of individual imported schistosomiasis cases, the current enzyme-linked immunosorbent assay (ELISA) lacks sensitivity and robustness. Therefore, a lateral flow (LF) assay was developed to test CAA in serum for individual diagnosis of imported active schistosome infections. Application of fluorescent submicron-sized up-converting phosphor technology (UPT) reporter particles increased analytical sensitivity compared to that of the standard ELISA method. Evaluation of the UPT-LF test with a selection of 40 characterized epidemiologic samples indicated a good correlation between signal intensity and infection intensity. Subsequently, the UPT-LF assay was applied to 166 serum samples of Dutch residents (immigrants and travelers) suspected of schistosomiasis, a case in which group routine antibody detection frequently fails straightforward diagnosis. The UPT-LF assay identified 36 CAA-positive samples, compared to 15 detected by CAA-ELISA. In conclusion, the UPT-LF assay is a low-complexity test with higher sensitivity than the CAA-ELISA, well suited for laboratory diagnosis of individual active Schistosoma infections.

14 May 2015 in PLOS Neglected Tropical Diseases
Verified
Journal Article
Open access
PDF file
SKStefanie Knopp
Stefanie Knopp
PCPaul Corstjens
Paul Corstjens
AKArtemis Koukounari
Artemis Koukounari
CCColin I Cercamondi
Colin I Cercamondi
SAShaali M Ame
Shaali M Ame
GDGovert J van Dam
Govert J van Dam
Elimination of schistosomiasis as a public health problem and interruption of transmission in selected areas are key goals of the World Health Organization for 2025. Conventional parasitological methods are insensitive for the detection of light-intensity infections. Techniques with high sensitivity and specificity are required for an accurate diagnosis in low-transmission settings and verification of elimination. We determined the accuracy of a urine-based up-converting phosphor-lateral flow circulating anodic antigen (UCP-LF CAA) assay for Schistosoma haematobium diagnosis in low-prevalence settings in Zanzibar, Tanzania. A total of 1,740 urine samples were collected in 2013 from children on Pemba Island, from schools where the S. haematobium prevalence was <2%, 2–5%, and 5–10%, based on a single urine filtration. On the day of collection, all samples were tested for microhematuria with reagent strips and for the presence of S. haematobium eggs with microscopy. Eight months later, 1.5 ml of urine from each of 1,200 samples stored at -20°C were analyzed by UCP-LF CAA assay, while urine filtration slides were subjected to quality control (QCUF). In the absence of a true ‘gold’ standard, the diagnostic performance was calculated using latent class analyses (LCA). The ‘empirical’ S. haematobium prevalence revealed by UCP-LF CAA, QCUF, and reagent strips was 14%, 5%, and 4%, respectively. LCA revealed a sensitivity of the UCP-LF CAA, QCUF, and reagent strips of 97% (95% confidence interval (CI): 91–100%), 86% (95% CI: 72–99%), and 67% (95% CI: 52–81%), respectively. Test specificities were consistently above 90%. The UCP-LF CAA assay shows high sensitivity for the diagnosis of S. haematobium in low-endemicity settings. Empirically, it detects a considerably higher number of infections than microscopy. Hence, the UCP-LF CAA employed in combination with QCUF, is a promising tool for monitoring and surveillance of urogenital schistosomiasis in low-transmission settings targeted for elimination. The World Health Organization aspires to eliminate snail fever (schistosomiasis) as a public health problem and to interrupt the transmission of this disease in selected areas by 2025. Efforts to achieve these goals are currently being intensified. As a result, the prevalence and intensity of infection will decline in many parts of the world. To detect light-intensity infections, diagnostic tools with a high sensitivity and specificity are needed. We assessed the accuracy of a method that is able to diagnose schistosomiasis via the detection of circulating anodic antigen (CAA) in urine. We examined 1,200 urine samples from children living on Pemba Island, Tanzania, a low-endemic area targeted for schistosomiasis elimination. We found that the CAA-test had a considerably higher sensitivity than conventional urine filtration microscopy and reagent strips that are widely used in schistosomiasis control programs. The empirical prevalence of infection with the parasite Schistosoma haematobium determined by the CAA-test was up to 10 times higher than that obtained by urine filtration. Our results suggest that the CAA-test—in combination with urine filtration—is a promising approach for the diagnosis of S. haematobium in low-transmission settings that are targeted for elimination.