Wajid Khan

Dr. Wajid Khan

ELECTRICAL AND INFORMATION ENGINEERING, Tianjin University, Tianjin, China
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TATahir Anwar
Tahir Anwar
CMChaoxu Mu
Chaoxu Mu
MYMuhammad Zain Yousaf
Muhammad Zain Yousaf
Wajid KhanWajid Khan
Wajid Khan
SKSaqib Khalid
Saqib Khalid
Ievgen ZaitsevIevgen Zaitsev
Ievgen Zaitsev
Transmission lines are vital for delivering electricity over long distances, yet they face reliability challenges due to faults that can disrupt power supply and pose safety risks. This research introduces a novel approach for fault detection and classification by analyzing voltage and current patterns across transmission line phases. Leveraging a comprehensive dataset of diverse fault scenarios, various machine learning algorithms—including Random Forest (RF), K-Nearest Neighbors (KNN), and Long Short-Term Memory (LSTM) networks—are evaluated. An ensemble methodology, RF-LSTM Tuned KNN, is proposed to enhance detection accuracy and robustness. Results indicate that RF-LSTM Tuned KNN achieves a remarkable accuracy of 99.96% on a multi-label dataset, outperforming RF (97.50%) and KNN (96.55%). In binary classification, KNN attains the highest accuracy of 99.85%, closely followed by RF at 99.72%. This methodology provides significant advancements in fault detection capabilities, offering valuable insights for improving grid reliability and stability, and ensuring a more resilient power supply.

8 January 2025 in IEEE Access
Verified
Journal Article
Open access
Renhai FengRenhai Feng
Renhai Feng
Wajid KhanWajid Khan
Wajid Khan
MFMuhammad Faheem
Muhammad Faheem
JWJiang Wang
Jiang Wang
FSFazal E. Subhan
Fazal E. Subhan
MBMuhammad Shoaib Bhutta
Muhammad Shoaib Bhutta
This paper focus on the application of Physics Informed Neural Network (PINN) for extracting parameters of photovoltaic (PV), wind, and energy storage equipment models. Accurately extracting the parameters of these models is essential for effectively controlling and optimizing the overall stability of Chongqing power system (CPS). Despite numerous algorithms proposed to tackle this issue, accurately and reliably extracting the parameters of these remains a significant challenge. This paper proposed an improved PINN, named Uniform Physics Informed Neural Network (UPINN), with Proximal Policy Optimization (PPO) based reinforcement learning, for extortion of parameters of these models. The PINN difficulty is overcome in UPINN by configuring four strategies: feedback operator, GRU gating mechanisms, transfer operator with historic population, and modification factor with PPO aided reinforcement learning. UPINN models are trained iteratively to maximize parameters and reduce RMSE. UPINN accurately extracts parameters and describes the behavior of PV, wind, and energy storage equipment models as it converges towards optimal solutions through parameter adjustments and RMSE evaluations. The UPINN was implemented for real-time voltage stability monitoring of CPS. The results show that UPINN performs better than other neural network models in respect of accuracy and stability, demonstrating the effectiveness of improved strategies. Moreover, its emphasis the importance of computed and estimated indices obtained through UPINN for predicting voltage collapse occurrences within the system.

15 February 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AAAbdul Aziz
Abdul Aziz
MYMuhammad Zain Yousaf
Muhammad Zain Yousaf
Renhai FengRenhai Feng
Renhai Feng
Wajid KhanWajid Khan
Wajid Khan
USUmar Siddique
Umar Siddique
Ievgen ZaitsevIevgen Zaitsev
Ievgen Zaitsev
Each substation is critically essential to the overall operation of the electrical power system. Potential dangers include thermal stress, noise, slip, trip, fall hazards, animal waste, and nonionizing radiation. These are the causes of joint failures of cables and overhead lines, failure of one or more phases of circuit breakers, and melting of fuses or conductors in one or more phases. These kinds of failures bring about a decline in the substation’s level of dependability. On the consumer side, power cannot be received adequately because there are losses in the transmission line. To accomplish the objective of enhancing the voltage profile, the DG must be optimized. The substation’s transient analysis utilizing a variety of factors, a study of faults and transients that occur in the substation and their effects using ETAP, and an optimization of a range of parameters using artificial intelligence techniques are all used for this goal. This paper offers the complete simulation of a 500kv substation. The simulation uses advanced software Electrical Transient Analyzer Program (ETAP) with detailed load flow analysis and short circuit study of the 500 kV substation system using ETAP software. From the ETAP-generated load flow details and the short circuit details, which are studied by varying loads or other parameters, these whole simulations are carried out multiple times using real-time data from the past eighteen months. A simulation data set contains data on both standard and different faulty conditions. In the 1st step, the normal and faulty conditions are classified. In the 2nd step, the reasons for fault occurrence include line-to-line, line-to-ground, and double line-to-ground using the Artificial Intelligence technique. In both steps, Catboost performs well, followed by Support Vector Machine and Logistic Regression. In the first step, Catboost classifies normal and faulty conditions with an accuracy of 98%, SVM is 96%, and Logistic regression is 93%. Again, in the 2nd step to identify different faulty conditions, the accuracies of Catboost SVM and Logistic Regression are 97%, 95%, and 92%, respectively.

3 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FRFeng Renhai
Feng Renhai
Wajid KhanWajid Khan
Wajid Khan
ATAfshan Tariq
Afshan Tariq
Muhammad AbbasMuhammad Abbas
Muhammad Abbas
MYMuhammad Zain Yousaf
Muhammad Zain Yousaf
MBMilkias Berhanu
Milkias Berhanu
As power systems around the world shift to incorporate more renewable energy sources, particularly wind power, maintaining grid stability becomes increasingly challenging due to the inherent variability of these sources. This paper introduces a novel bi-level robust optimization framework that enhances the capabilities of adaptive Under-Frequency Load Shedding (AUFLS) in managing the uncertainties brought by high penetration of wind energy and dynamic participation of electric vehicles (EVs). Central to this framework is an innovative adaptive non-parametric Kernel Density Estimation (AAKDE) technique, which sharpens the accuracy of wind power fluctuation predictions. This method enables more precise and efficient control of load-shedding events, which is crucial for preventing frequency drops that can lead to grid instability. This research proposes a strategic shedding queue mechanism that systematically prioritizes the discharge of EVs based on their real-time state-of-charge and charging behavior. This prioritization minimizes user discomfort and taps into the potential of EVs as flexible energy resources, thus providing substantial support to grid operations. To enhance the responsiveness of our AUFLS approach, we integrate a reinforcement learning model that adjusts in real time to grid conditions, optimizing decision-making for frequency stabilization. Our extensive MATLAB/SIMULINK simulations on an upgraded IEEE 39 bus test system demonstrate a significant reduction in load shedding requirements. Compared to traditional AUFLS methods, our approach cuts load shedding by over 50%, effectively maintains system frequency within safe operational limits, and shows superior performance in scenarios of high renewable variability and EV integration. This research highlights the potential of adaptive non-parametric methods in transforming AUFLS strategies, paving the way for smarter, more resilient power systems equipped to handle the complexities of modern energy landscapes.

16 October 2025 in Energy Exploration & Exploitation
Verified
Journal Article
Open access
Wajid KhanWajid Khan
Wajid Khan
FRFeng Renhai
Feng Renhai
AAAbdul Aziz
Abdul Aziz
MYMuhammad Zain Yousaf
Muhammad Zain Yousaf
ZCZhi Cai
Zhi Cai
MGMebratu Sintie Geremew
Mebratu Sintie Geremew
Meeting the growing global electricity demand in remote and off-grid regions requires cost-effective and reliable power solutions that overcome the intermittency of renewable energy sources. This paper presents a comprehensive techno-economic optimization framework for the design and operation of off-grid hybrid renewable energy systems (HRES) integrating photovoltaic (PV), wind turbine, biomass generator, diesel backup, and a dual-chemistry hybrid battery energy storage system (HBESS) combining lithium-ion and nickel-iron batteries. A detailed mathematical modeling approach is employed to capture the nonlinear dynamics, stochastic renewable behavior, battery degradation, and temperature-adjusted component efficiencies. The system is formulated as a multi-objective mixed-integer nonlinear programming problem targeting the minimization of life cycle cost (LCC), levelized cost of energy (LCOE), and CO 2 emissions while satisfying reliability constraints such as loss of power supply probability (LPSP < 0.01). To solve the optimization problem, advanced metaheuristic algorithms—Particle Swarm Optimization (PSO), Genetic Algorithms (GA), Grey Wolf Optimizer (GWO), and Differential Evolution (DE), and Salp Swarm Algorithm (SSA)—and a Deep Q-Network (DQN)-based reinforcement learning energy management strategy are implemented and benchmarked. The proposed DQN-based controller demonstrates superior performance over conventional rule-based and static dispatch methods by maintaining more stable battery state-of-charge (SOC) profiles, reducing degradation, and enabling intelligent real-time decision-making. Simulation results based on realistic meteorological and demand profiles reveal that the integrated DQN and HBESS strategy reduces total LCC by over 20%, CO 2 emissions by up to 30%, and battery degradation costs by over 10% compared to baseline systems. The Salp Swarm Algorithm (SSA) achieves the fastest convergence and the highest-quality Pareto-optimal solutions among all metaheuristics evaluated. Sensitivity analysis identifies diesel price and interest rate as the most influential parameters on LCOE, while load shifting through aggressive demand-side management further minimizes battery usage, operating costs, and emissions. The proposed framework not only addresses key challenges in off-grid microgrid design but also provides a scalable and robust pathway for sustainable rural electrification using hybrid storage and intelligent control.

30 June 2024 in Electronics
Verified
Journal Article
Open access
PDF file
ZCZhi Cai
Zhi Cai
YWYanfeng Wang
Yanfeng Wang
DZDawei Zhang
Dawei Zhang
LWLili Wen
Lili Wen
HLHaiyang Liu
Haiyang Liu
Renhai FengRenhai Feng
Renhai Feng
The safe and steady operation of hydropower generation systems is crucial for electricity output in the grid. However, hydropower stations have complicated interior structures, making defect detection difficult without disassembly inspections. The application of digital modeling to hydropower stations will effectively promote the intelligent transformation of hydropower stations as well as reduce the maintenance costs of the system. This study provides a model of the power generating and transmission system for hydropower plants, with an emphasis on primary equipment and measured data. The model utilizes PSCAD to digitalize state response in hydropower plants with various short-circuit faults. The fault information is identified and learned using the Adaptive Time–Frequency Memory (AD-TFM) deep learning model. It is demonstrated that our proposed method can effectively obtain the fault information through radio frequency identification (RFID). The accuracy of the traditional method is 0.90, while the results for AD-TFM show a fault classification accuracy of 0.92, which is more than enough to identify multiple fault types compared to the existing methods.