Sara Jayne McCullough

Dr. Sara Jayne McCullough

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SMSara Jayne McCullough
Sara Jayne McCullough
LOLisa O’donoghue
Lisa O’donoghue
KSKathryn J. Saunders
Kathryn J. Saunders
To determine six-year spherical refractive error change among white children and young adults in the UK and evaluate differences in refractive profiles between contemporary Australian children and historical UK data. Population-based prospective study. The Northern Ireland Childhood Errors of Refraction (NICER) study Phase 1 examined 1068 children in two cohorts aged 6–7 years and 12–13 years. Prospective data for six-year follow-up (Phase 3) are available for 212 12–13 year olds and 226 18–20 year olds in each cohort respectively. Cycloplegic refractive error was determined using binocular open-field autorefraction (Shin-Nippon NVision-K 5001, cyclopentolate 1%). Participants were defined by spherical equivalent refraction (SER) as myopic SER ≤-0.50D, emmetropic -0.50D<SER<+2.00 or hyperopic SER≥+2.00D. Proportion and incidence of myopia. The proportion of myopes significantly increased between 6–7 years (1.9%) and 12–13 years (14.6%) (p<0.001) but not between 12–13 and 18–20 years (16.4% to 18.6%, p = 0.51). The estimated annual incidence of myopia was 2.2% and 0.7% for the younger and older cohorts respectively. There were significantly more myopic children in the UK at age 12–13 years in the NICER study (16.4%) than reported in Australia (4.4%) (p<0.001). However by 17 years the proportion of myopia neared equivalence in the two populations (NICER 18.6%, Australia 17.7%, p = 0.75). The proportion of myopic children aged 12–13 years in the present study (2006–2008) was 16.4%, significantly greater than that reported for children aged 10–16 years in the 1960’s (7.2%, p = 0.01). The proportion of hyperopes in the younger NICER cohort decreased significantly over the six year period (from 21.7% to 14.2%, p = 0.04). Hyperopes with SER ≥+3.50D in both NICER age cohorts demonstrated persistent hyperopia. The incidence and proportion of myopia are relatively low in this contemporary white UK population in comparison to other worldwide studies. The proportion of myopes in the UK has more than doubled over the last 50 years in children aged between 10–16 years and children are becoming myopic at a younger age. Differences between the proportion of myopes in the UK and in Australia apparent at 12–13 years were eliminated by 17 years of age.

1 August 2014 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JLJulie-Anne Little
Julie-Anne Little
SMSara Jayne McCullough
Sara Jayne McCullough
KBKaren M. M. Breslin
Karen M. M. Breslin
KSKathryn J. Saunders
Kathryn J. Saunders
Purpose. The interaction between higher order ocular aberrations (HOA) and refractive error is not yet fully understood. This study investigated HOA in relation to refractive error and ocular biometric parameters in a population with a high prevalence of ametropia. Methods. The HOA were investigated in two cohorts of Caucasian children aged 9 to 10 and 15 to 16 years (n = 313). These aberrations were measured for a 5-mm pupil with the IRX3 aberrometer. Cycloplegic refractive error and ocular biometry measures, including axial length and corneal curvature, also were assessed with the Shin-Nippon SRW-5000 auto-refractor and Zeiss IOLMaster, respectively. Participants were divided into refractive groups for analysis of HOA. Results. The magnitude of total HOA was higher in this population at 0.27 μm (interquartile range [IQR], 0.22–0.32 μm) than other HOA reported in the literature. The profile of HOA was not significantly different across the two age cohorts or across refractive groups, nor did spherical aberration differ significantly with age ( = 0.07 μm for both cohorts). Multivariate linear regression analysis demonstrated spherical aberration was significantly related to axial length (but not refractive grouping), with longer eyes having less positive values of fourth order and root mean square (RMS) spherical aberration. Conclusions. This study found no significant difference in HOA across refractive groups. The current study also highlights the importance of knowledge of axial length when analyzing HOA.

7 October 2024 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
TNThomas Naduvilath
Thomas Naduvilath
Xiangui HeXiangui He
Xiangui He
KSKathryn Saunders
Kathryn Saunders
PDPelsin Demir
Pelsin Demir
RLRebecca Leighton
Rebecca Leighton
Nina TahhanNina Tahhan
Nina Tahhan
Aim: To determine the regional and ethnic differences in ocular axial elongation and refractive error progression in myopic and non‐myopic children. Methods: A retrospective analysis of 15 longitudinal clinical and population‐based studies was conducted in the UK, Sweden, Australia (classified as European), China, and Vietnam (classified as East Asian) between 2005 and 2021. A total of 14,593 data points from 6208 participants aged 6–16 years with spherical equivalent from +6 to −6 D were analysed. Progression was annualised from longitudinal axial length and cycloplegic spherical equivalent (SE) refraction. Generalised estimating equation models including main effects and interactions were used for model building. Age and region‐specific estimates for myopes and non‐myopes and confidence intervals are reported. Results: Factors affecting axial elongation and SE progression in children included being myopic, followed by age, region/ethnicity and sex. The magnitude of regional/ethnic differences was dependent on myopia and age. Axial elongation and SE progression were lower in European compared with East Asian children, but differences were reduced with increasing age and differences in axial elongation were larger in myopes than non‐myopes. Age‐specific regional/ethnic differences indicated that axial elongation for a 6‐year‐old East Asian myopic child was greater than a European child by 0.15 mm/year (0.58 vs. 0.43 mm/year) and by 0.09 mm/year (0.35 vs. 0.26 mm/year) for a 10‐year‐old myope. SE progression was lower in a 6‐year‐old European myope by 0.48 D/year and at 10 years of age by 0.34 D/year compared with an East Asian myope. Conclusions: There are regional/ethnic differences in age‐specific refractive and axial growth patterns in both myopic and non‐myopic eyes, with more marked differences in younger East Asian children who demonstrated a higher axial growth and greater negative SE shift than their non‐Asian peers. Regional/ethnic differences in progression reflect environmental and ethnic variations. Age and region/ethnicity‐specific estimates could contribute as a reference for future comparisons.

24 June 2019 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
SDSue E Doherty
Sue E Doherty
Lesley DoyleLesley Doyle
Lesley Doyle
SMSara Jayne McCullough
Sara Jayne McCullough
KSKathryn J Saunders
Kathryn J Saunders

13 August 2021 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
PDF file
CHColleen M Howell
Colleen M Howell
SMSara Jayne McCullough
Sara Jayne McCullough
Lesley DoyleLesley Doyle
Lesley Doyle
MMMarie H Murphy
Marie H Murphy
KSKathryn J Saunders
Kathryn J Saunders
Purpose: To compare real‐world measures of illumination obtained with the Actiwatch‐2 and Clouclip‐M2 with ‘gold standard’ photometry measures and to evaluate the ability of Actiwatch‐2 to correctly identify photometer‐defined conditions: scotopic (≤0.01 lux), mesopic (0.02–3 lux), indoor photopic (>3–1,000 lux) and outdoor photopic (>1,000 lux); and Clouclip to correctly identify photometer‐defined conditions within its operating range (>1 lux). Inter‐device reliability of Clouclip for illumination and viewing distance measures was also investigated. Methods: A Hagner‐S2 photometer was used as reference. Measures of illumination were obtained from a range of real‐world conditions. To investigate inter‐device reliability, five Clouclips were simultaneously exposed to varied light conditions and object distances. Results: Strong correlations existed between illumination measured with the photometer and both Actiwatch‐2 (ρ = 0.99, p  < 0.0001) and Clouclip (ρ = 0.99, p  < 0.0001). However, both devices underestimated illumination compared to the photometer; disparity increased with increasing illumination and was greater for Actiwatch‐2 than Clouclip measures. Actiwatch‐2 successfully categorised illumination level (scotopic, mesopic, indoor and outdoor photopic) in 71.2% of cases. Clouclip successfully categorised illumination levels as scotopic/mesopic (≤3 lux) and indoor and outdoor photopic in 100% of cases. Mean differences and limits of agreement (LOA) were 430.92 ± 1,828.74 and 79.35 ± 407.33 lux, between the photometer and Actiwatch‐2 and photometer and Clouclip, respectively. The Intra‐class Correlation Coefficients for illumination and viewing distance measured with five Clouclips were 0.85 and 0.96, respectively. Conclusion: These data illustrate that different Clouclip devices produce comparable measures of viewing distance and illumination in real‐world settings. Both Actiwatch‐2 and Clouclip underestimate illumination in the field compared to gold standard photometer measures. The disparity increases at higher levels of illumination and the discrepancy was greater for Actiwatch‐2 measures. For researchers interested in categorising light exposure, Clouclip classifies illumination levels >2 lux more accurately than Actiwatch‐2 but cannot discriminate between scotopic and low mesopic light.

28 December 2016 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
SMSara Jayne McCullough
Sara Jayne McCullough
Lesley DoyleLesley Doyle
Lesley Doyle
KSKathryn J. Saunders
Kathryn J. Saunders