The majority of individuals with Down syndrome (DS) do not exhibit accurate accommodation, with the aetiology of this deficit unknown. This study examines the mechanism underlying hypoaccommodation in DS by simultaneously investigating the ‘near triad’ – accommodation, vergence and pupillary response. An objective photorefraction system measured accommodation, pupil size and gaze position (vergence) under binocular conditions while participants viewed an animated movie at 50, 33, 25 and 20 cm. Participants were aged 6–16 years (DS = 41, controls = 76). Measures were obtained from 59% of participants with DS and 99% of controls. Accommodative response was significantly less in DS (p < 0.001) and greater accommodative deficits were associated with worsening visual acuity (p = 0.02). Vergence responses were as accurate in DS as in controls (p = 0.90). Habitual pupil diameter did not differ between groups (p = 0.24) but reduced significantly with increasing accommodative demand in both participants with and without DS (p < 0.0001). This study is the first to report simultaneous binocular measurement of the near triad in DS demonstrating that hypoaccommodation is linked to poor visual acuity. Vergence responses were accurate indicating that hypoaccommodation cannot be dismissed as a failure to visually engage with near targets, but rather is a consequence of underlying neurological or physiological deficits.
24 June 2019 in Ophthalmic and Physiological Optics
Purpose: To compare real‐world measures of illumination obtained with the Actiwatch‐2 and Clouclip‐M2 with ‘gold standard’ photometry measures and to evaluate the ability of Actiwatch‐2 to correctly identify photometer‐defined conditions: scotopic (≤0.01 lux), mesopic (0.02–3 lux), indoor photopic (>3–1,000 lux) and outdoor photopic (>1,000 lux); and Clouclip to correctly identify photometer‐defined conditions within its operating range (>1 lux). Inter‐device reliability of Clouclip for illumination and viewing distance measures was also investigated. Methods: A Hagner‐S2 photometer was used as reference. Measures of illumination were obtained from a range of real‐world conditions. To investigate inter‐device reliability, five Clouclips were simultaneously exposed to varied light conditions and object distances. Results: Strong correlations existed between illumination measured with the photometer and both Actiwatch‐2 (ρ = 0.99, p < 0.0001) and Clouclip (ρ = 0.99, p < 0.0001). However, both devices underestimated illumination compared to the photometer; disparity increased with increasing illumination and was greater for Actiwatch‐2 than Clouclip measures. Actiwatch‐2 successfully categorised illumination level (scotopic, mesopic, indoor and outdoor photopic) in 71.2% of cases. Clouclip successfully categorised illumination levels as scotopic/mesopic (≤3 lux) and indoor and outdoor photopic in 100% of cases. Mean differences and limits of agreement (LOA) were 430.92 ± 1,828.74 and 79.35 ± 407.33 lux, between the photometer and Actiwatch‐2 and photometer and Clouclip, respectively. The Intra‐class Correlation Coefficients for illumination and viewing distance measured with five Clouclips were 0.85 and 0.96, respectively. Conclusion: These data illustrate that different Clouclip devices produce comparable measures of viewing distance and illumination in real‐world settings. Both Actiwatch‐2 and Clouclip underestimate illumination in the field compared to gold standard photometer measures. The disparity increases at higher levels of illumination and the discrepancy was greater for Actiwatch‐2 measures. For researchers interested in categorising light exposure, Clouclip classifies illumination levels >2 lux more accurately than Actiwatch‐2 but cannot discriminate between scotopic and low mesopic light.
28 December 2016 in Ophthalmic and Physiological Optics
Purpose: Controversy exists regarding the influence of peripheral visual experience on the onset and progression of childhood myopia. This longitudinal, observational study evaluated the relationship between relative peripheral refraction (RPR) and changes in refractive error and axial length (AL) over 12 months in White children aged 6–7 and 12–13 years with a range of baseline refractive errors. Methods: Cycloplegic baseline autorefraction at horizontal retinal eccentricities of 0° and ±30° were recorded with the Shin‐Nippon NVision‐K 5001 while AL was measured using the Zeiss IOLMaster 700. Measurements were repeated after 12 months on a subgroup. Refractive data were transposed into power vectors as mean spherical equivalent (M), J 0 and J 45 . RPR was calculated by subtracting central from peripheral measurements. Participants were defined as myopic (M ≤ −0.50 D), premyopic (−0.50 D < M ≤ +0.75 D), emmetropic (+0.75 D < M < +2.00 D) or hyperopic (M ≥ +2.00 D). Results: Data were collected from 222 and 245 participants aged 6–7 and 12–13 years, respectively. Myopic eyes demonstrated, on average, more hyperopic RPR. Emmetropes and premyopes displayed emmetropic RPR, and hyperopes showed a myopic RPR. Fifty‐six 6‐ to 7‐year‐olds and seventy 12‐ to 13‐year‐olds contributed 12‐month repeated measures. Longitudinal data demonstrated a significant relationship between a more hyperopic RPR in the nasal retina and greater short‐term axial elongation in teens with myopia at baseline (β = 0.69; p = 0.04). Each dioptre of relative peripheral hyperopia in the nasal retina was associated with an additional 0.10 mm (95% CI: 0.02–0.18 mm) annual increase in AL. Conclusions: Hyperopic RPR in the nasal retina of myopic children is indicative of increased risk for rapid axial elongation and may be a useful metric to support decision‐making in myopia management.
7 April 2019 in Ophthalmic and Physiological Optics