Mustafa Suphi Erden

Dr. Mustafa Suphi Erden


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2008 in Artificial Intelligence for Engineering Design, Analysis and Manufacturing
Verified
Journal Article
Closed access
PDF file
MEMustafa Suphi Erden
Mustafa Suphi Erden
HKH. Komoto
H. Komoto
TBT.J. van Beek
T.J. van Beek
VDV. D'AMelio
V. D'AMelio
EEE. Echavarria
E. Echavarria
TTT. Tomiyama
T. Tomiyama
This work is aimed at establishing a common frame and understanding offunction modeling(FM) for our ongoing research activities. A comparative review of the literature is performed to grasp the various FM approaches with their commonalities and differences. The relations of FM with the research fields of artificial intelligence, design theory, and maintenance are discussed. In this discussion the goals are to highlight the features of various classical approaches in relation to FM, to delineate what FM introduces to these fields, and to discuss the applicability of various FM approaches in these fields. Finally, the basic ideas underlying our projects are introduced with reference to the general framework of FM.

11 July 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
AKAgamemnon Krasoulis
Agamemnon Krasoulis
IKIris Kyranou
Iris Kyranou
MEMustafa Suphi Erden
Mustafa Suphi Erden
KNKianoush Nazarpour
Kianoush Nazarpour
SVSethu Vijayakumar
Sethu Vijayakumar
Myoelectric pattern recognition systems can decode movement intention to drive upper-limb prostheses. Despite recent advances in academic research, the commercial adoption of such systems remains low. This limitation is mainly due to the lack of classification robustness and a simultaneous requirement for a large number of electromyogram (EMG) electrodes. We propose to address these two issues by using a multi-modal approach which combines surface electromyography (sEMG) with inertial measurements (IMs) and an appropriate training data collection paradigm. We demonstrate that this can significantly improve classification performance as compared to conventional techniques exclusively based on sEMG signals. We collected and analyzed a large dataset comprising recordings with 20 able-bodied and two amputee participants executing 40 movements. Additionally, we conducted a novel real-time prosthetic hand control experiment with 11 able-bodied subjects and an amputee by using a state-of-the-art commercial prosthetic hand. A systematic performance comparison was carried out to investigate the potential benefit of incorporating IMs in prosthetic hand control. The inclusion of IM data improved performance significantly, by increasing classification accuracy (CA) in the offline analysis and improving completion rates (CRs) in the real-time experiment. Our findings were consistent across able-bodied and amputee subjects. Integrating the sEMG electrodes and IM sensors within a single sensor package enabled us to achieve high-level performance by using on average 4-6 sensors. The results from our experiments suggest that IMs can form an excellent complimentary source signal for upper-limb myoelectric prostheses. We trust that multi-modal control solutions have the potential of improving the usability of upper-extremity prostheses in real-life applications.

8 February 2010 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
MEMustafa Suphi Erden
Mustafa Suphi Erden
TTTetsuo Tomiyama
Tetsuo Tomiyama
In this paper, a physically interactive control scheme is developed for a manipulator robot arm. The human touches the robot and applies force in order to make it behave as he/she likes. The communication between the robot and the human is maintained by a physical contact with no sensors. The intent of the human is estimated by observing the change in control effort. The robot receives the estimated human intent and updates its position reference accordingly. The developed method uses the principle of conservation of zero momentum for position-controlled systems. A switching scheme is developed that goes between the modes of pure impedance control with a fixed-position reference and interactive control under human intent. The switching mechanism uses neither a physical switch nor a sensor; it observes the human intent and puts the robot into interactive mode, if there is any. When the human intent disappears, the robot goes into the pure-impedance-control mode, thus stabilizing in the left position.

1 August 2011 in Robotics and Computer-Integrated Manufacturing
Verified
Journal Article
Closed access
MEMustafa Suphi Erden
Mustafa Suphi Erden
BMBobby Marić
Bobby Marić

1 December 2010 in Mechatronics
Verified
Journal Article
Closed access
TBThom J. van Beek
Thom J. van Beek
MEMustafa Suphi Erden
Mustafa Suphi Erden
TTTetsuo Tomiyama
Tetsuo Tomiyama

27 January 2015 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
MEMustafa Suphi Erden
Mustafa Suphi Erden
ABAude Billard
Aude Billard
This paper presents a study of hand impedance measurements comparatively across ten professional and 14 novice manual welders, when they are performing tungsten inert gas (TIG) welding interactively with the KUKA lightweight robot arm (LWR). The results show that hand impedance differs across professional and novice welders. The welding torch is attached to the KUKA LWR, which is admittance controlled via a force sensor to give the feeling of a free floating mass at its end-effector. The subjects perform TIG welding on 1.5-mm-thick stainless steel plates by manipulating the torch. Impedance is measured by introducing external force disturbances and fitting a mass-damper-spring model to human hand reactions. The quality of welding is measured using the variance of the position signals above 0.1 Hz. Professional welders demonstrate less variance and, in general, apply larger hand impedance (larger damping and stiffness) than the novice welders. The variance of position during nominal welding is minimal for both professional and novice welders in the direction perpendicular to the welding line in the plane of the plate, which is the most important direction for the quality of the weld. For both professional and novice welders, the mass and damping values are largest in this direction compared with the other two directions. Professional welders demonstrate larger damping than the novice welders in this direction.